Microreplication and Design of Biological Architectures Using Dynamic‐Mask Multiphoton Lithography
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A strategy for rapidly printing three‐dimensional (3D) microscopic replicas using multiphoton lithography directed by a dynamic electronic mask is reported. Morphological descriptions of 3D structures are encoded as stacks of 2D slices created from tomographic and computer‐designed instruction sets. In this manner, digital images serve as input for a sequence of reflective photomasks on a digital micromirror device to direct replication of a structure. By scanning a laser focus across the face of the intrinsically aligned masks, tomographic and computed data can be translated into protein‐based 3D reproductions with submicrometer feature sizes within 1 min. This straightforward and highly versatile approach may provide improved routes for the development of 3D cellular scaffolds, rapid prototyping of microanalytical devices, and production of custom tissue replacements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finer features for functional microdevices
Kawata, S., Sun, H.-B., Tanaka, T., & Takada, K. (2001) · Nature · doi:10.1038/35089130 · Cited by 2,871
Direct laser writing of three-dimensional photonic-crystal templates for telecommunications
Deubel, M., von Freymann, G., Wegener, M., Pereira, S., Busch, K., & Soukoulis, C. M. (2004) · Nature Materials · doi:10.1038/nmat1155 · Cited by 1,083
Cited by
Green Synthesis of Metallic Nanoparticles via Biological Entities
Shah, M., Fawcett, D., Sharma, S., Tripathy, S., & Poinern, G. (2015) · Materials · doi:10.3390/ma8115377 · Cited by 1,292
Hydrogel microparticles for biomedical applications
Daly, A. C., Riley, L., Segura, T., & Burdick, J. A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0148-6 · Cited by 1,249
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
Au, A. K., Huynh, W., Horowitz, L. F., & Folch, A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201504382 · Cited by 788
Direct‐write bioprinting three‐dimensional biohybrid systems for future regenerative therapies
Chang, C. C., Boland, E. D., Williams, S. K., & Hoying, J. B. (2011) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31831 · Cited by 445
Metadata
- Authors
- Nielson, R., Kaehr, B., & Shear, J. B.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2009-01
- Volume
- 5
- Issue
- 1
- Pages
- 120-125
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2005037691
- Cited by
- 140
- References
- 2
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.