The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
TiO2 Nanotube Surfaces: 15 nm—An Optimal Length Scale of Surface Topography for Cell Adhesion and Differentiation
Abstract
Using aligned TiO2 nanotubes with different diameters in the range between 15 and 100 nm synthesized on titanium by an electrochemical approach, it is shown that 15 nm is a universal surface geometric constant that promotes cell adhesion, proliferation, migration, and differentiation of different cell types (such as mesenchymal stem cells and hematopoietic stem cells; see image).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED ARTICLE: Pluripotency of mesenchymal stem cells derived from adult marrow
Jiang, Y., Jahagirdar, B. N., Reinhardt, R. L., Schwartz, R. E., Keene, C. D., Ortiz-Gonzalez, X. R., Reyes, M., Lenvik, T., Lund, T., Blackstad, M., et al. (2002) · Nature · doi:10.1038/nature00870 · Cited by 5,518
RetractedOsteoblastic cells regulate the haematopoietic stem cell niche
Calvi, L. M., Adams, G. B., Weibrecht, K. W., Weber, J. M., Olson, D. P., Knight, M. C., Martin, R. P., Schipani, E., Divieti, P., Bringhurst, F. R., et al. (2003) · Nature · doi:10.1038/nature02040 · Cited by 3,455
Identification of the haematopoietic stem cell niche and control of the niche size
Zhang, J., Niu, C., Ye, L., Huang, H., He, X., Tong, W.-G., Ross, J., Haug, J., Johnson, T., Feng, J. Q., et al. (2003) · Nature · doi:10.1038/nature02041 · Cited by 2,959
Conditions controlling the proliferation of haemopoietic stem cells in vitro
Dexter, T. M., Allen, T. D., & Lajtha, L. G. (1977) · Journal of Cellular Physiology · doi:10.1002/jcp.1040910303 · Cited by 2,066
Gregory, C. A., Grady Gunn, W., Peister, A., & Prockop, D. J. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.02.002 · Cited by 1,561
Nanosize and Vitality: TiO2 Nanotube Diameter Directs Cell Fate
Park, J., Bauer, S., von der Mark, K., & Schmuki, P. (2007) · Nano Letters · doi:10.1021/nl070678d · Cited by 1,193
Self-citationHigh‐Aspect‐Ratio TiO2 Nanotubes by Anodization of Titanium
Macák, J. M., Tsuchiya, H., & Schmuki, P. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200462459 · Cited by 1,184
Self-citationTakagi, J., Petre, B. M., Walz, T., & Springer, T. A. (2002) · Cell · doi:10.1016/s0092-8674(02)00935-2 · Cited by 1,168
Activation of Integrin Function by Nanopatterned Adhesive Interfaces
Arnold, M., Cavalcanti‐Adam, E. A., Glass, R., Blümmel, J., Eck, W., Kantlehner, M., Kessler, H., & Spatz, J. P. (2004) · ChemPhysChem · doi:10.1002/cphc.200301014 · Cited by 1,164
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Cited by
Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface
Brammer, K. S., Oh, S., Cobb, C. J., Bjursten, L. M., Heyde, H. V. D., & Jin, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.008 · Cited by 593
Biopolymer-based functional composites for medical applications
Park, S.-B., Lih, E., Park, K.-S., Joung, Y. K., & Han, D. K. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.12.003 · Cited by 429
Doped TiO2 and TiO2 Nanotubes: Synthesis and Applications
Nah, Y., Paramasivam, I., & Schmuki, P. (2010) · ChemPhysChem · doi:10.1002/cphc.201000276 · Cited by 405
Self-citationInfluence of Surface Topographical Cues on the Differentiation of Mesenchymal Stem Cells in Vitro
Metavarayuth, K., Sitasuwan, P., Zhao, X., Lin, Y., & Wang, Q. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00377 · Cited by 189
Exosome-integrated titanium oxide nanotubes for targeted bone regeneration
Wei, F., Li, M., Crawford, R., Zhou, Y., & Xiao, Y. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.006 · Cited by 184
Metadata
- Authors
- Park, J., Bauer, S., Schlegel, K. A., Neukam, F. W., von der Mark, K., & Schmuki, P.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2009-03-20
- Volume
- 5
- Issue
- 6
- Pages
- 666-671
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2168696958
- Cited by
- 527
- References
- 24
- FWCI
- 22.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: TiO2 Nanotube Surfaces: 15 nm—An Optimal Length Scale of Surface Topography for Cell Adhesion and Differentiation. https://app.cochat.ai/papers/10.1002/smll.200801476
- The paper
- Park, J., Bauer, S., Schlegel, K. A., Neukam, F. W., von der Mark, K., & Schmuki, P. (2009). TiO2 Nanotube Surfaces: 15 nm—An Optimal Length Scale of Surface Topography for Cell Adhesion and Differentiation. Small. https://doi.org/10.1002/smll.200801476
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.