The DOI matches its Crossref record; 235 of the 235 references it cites were found in a registry or an index.
Microfluidic Devices for Bioapplications
Open accessAbstract
Harnessing the ability to precisely and reproducibly actuate fluids and manipulate bioparticles such as DNA, cells, and molecules at the microscale, microfluidics is a powerful tool that is currently revolutionizing chemical and biological analysis by replicating laboratory bench‐top technology on a miniature chip‐scale device, thus allowing assays to be carried out at a fraction of the time and cost while affording portability and field‐use capability. Emerging from a decade of research and development in microfluidic technology are a wide range of promising laboratory and consumer biotechnological applications from microscale genetic and proteomic analysis kits, cell culture and manipulation platforms, biosensors, and pathogen detection systems to point‐of‐care diagnostic devices, high‐throughput combinatorial drug screening platforms, schemes for targeted drug delivery and advanced therapeutics, and novel biomaterials synthesis for tissue engineering. The developments associated with these technological advances along with their respective applications to date are reviewed from a broad perspective and possible future directions that could arise from the current state of the art are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–235 of 235
Zolotarjova, N. I., Mrozinski, P., Chen, H., & Martosella, J. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.082 · Cited by 82
Surface Vibration Induced Spatial Ordering of Periodic Polymer Patterns on a Substrate
Álvarez, M., Friend, J. R., & Yeo, L. Y. (2008) · Langmuir · doi:10.1021/la802255b · Cited by 82
Self-citationvan Noort, D., Ong, S., Zhang, C., Zhang, S., Arooz, T., & Yu, H. (2009) · Biotechnology Progress · doi:10.1002/btpr.171 · Cited by 81
Enhanced Lung Gene Expression After Aerosol Delivery of Concentrated pDNA/PEI Complexes
Davies, L. A., McLachlan, G., Jones, S., Ferguson, D. J. P., Baker, A., Tennant, P. A., Gordon, C., Vrettou, C., Baker, E., Zhu, J., et al. (2008) · Molecular Therapy · doi:10.1038/mt.2008.96 · Cited by 79
Continuous On-Chip Micropumping for Microneedle Enhanced Drug Delivery
Zahn, J. D., Deshmukh, A. A., Pisano, A. P., & Liepmann, D. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000042047.83433.96 · Cited by 78
Erickson, D., Liu, X., Venditti, R., et al. (2005) · Analytical Chemistry · doi:10.1021/ac050236r · Cited by 76
Reproducible Two-Dimensional Capillary Electrophoresis Analysis of Barrett's Esophagus Tissues
Kraly, J. R., Jones, M. R., González‐Gómez, D., Dickerson, J. A., Harwood, M. M., Eggertson, M. J., Paulson, T. G., Sanchez, C. A., Odze, R. D., Feng, Z., et al. (2006) · Analytical Chemistry · doi:10.1021/ac061029+ · Cited by 75
Microfluidic technologies for MALDI‐MS in proteomics
DeVoe, D. L., & Lee, C. S. (2006) · Electrophoresis · doi:10.1002/elps.200600224 · Cited by 73
Microfluidics at the crossroad with point-of-care diagnostics
Linder, V. (2007) · The Analyst · doi:10.1039/b706347d · Cited by 70
Li, H., Friend, J. R., Yeo, L. Y., Dasvarma, A., & Traianedes, K. (2009) · Biomicrofluidics · doi:10.1063/1.3194282 · Cited by 68
Self-citationNishikawa, M., Yamamoto, T., Kojima, N., Komori, K., Fujii, T., & Sakai, Y. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21690 · Cited by 66
Online CE−MALDI-TOF MS Using a Rotating Ball Interface
Musyimi, H. K., Narcisse, D. A., Zhang, X., Stryjewski, W. J., Soper, S. A., & Murray, K. K. (2004) · Analytical Chemistry · doi:10.1021/ac0489723 · Cited by 65
Yeung, S. H. I., Liu, P., Bueno, N. D., Greenspoon, S. A., & Mathies, R. A. (2008) · Analytical Chemistry · doi:10.1021/ac8018685 · Cited by 63
Gordon, J. E., Gagnon, Z. R., & Chang, H. (2007) · Biomicrofluidics · doi:10.1063/1.2818767 · Cited by 61
Self-citationMicrofluidics with MALDI analysis for proteomics—A review
Lee, J., Soper, S. A., & Murray, K. K. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.037 · Cited by 60
Yeung, S. H. I., Greenspoon, S. A., McGuckian, A., Crouse, C. A., Emrich, C. A., Ban, J. D., & Mathies, R. A. (2006) · Journal of Forensic Sciences · doi:10.1111/j.1556-4029.2006.00153.x · Cited by 59
A Microfluidic Device for Measuring Cellular Membrane Potential
Farinas, J., Chow, A. W., & Wada, H. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5202 · Cited by 57
Determination of Kinetic Parameters, Km and kcat, with a Single Experiment on a Chip
Jambovane, S. R., Duin, E. C., Kim, S., & Hong, J. W. (2009) · Analytical Chemistry · doi:10.1021/ac8020938 · Cited by 51
Spatially Patterned Gene Delivery for Localized Neuron Survival and Neurite Extension
Houchin‐Ray, T., Whittlesey, K. J., & Shea, L. D. (2007) · Molecular Therapy · doi:10.1038/sj.mt.6300106 · Cited by 50
The future of microfluidic assays in drug development
Wen, Y., & Yang, S. (2008) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.3.10.1237 · Cited by 48
Rapid on-chip genetic detection microfluidic platform for real world applications
Senapati, S., Mahon, A. R., Gordon, J. E., Nowak, C., Sengupta, S., Powell, T. H. Q., Feder, J. L., Lodge, D. M., & Chang, H. (2009) · Biomicrofluidics · doi:10.1063/1.3127142 · Cited by 44
Self-citationSimultaneous microchip enzymatic measurements of blood lactate and glucose
Wang, J., Chatrathi, M. P., & Collins, G. E. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.001 · Cited by 43
Romanova, E. V., Fosser, K. A., Rubakhin, S. S., Nuzzo, R. G., & Sweedler, J. V. (2004) · The FASEB Journal · doi:10.1096/fj.03-1368fje · Cited by 41
Cell separation by the combination of microfluidics and optical trapping force on a microchip
Murata, M., Okamoto, Y., Park, Y.-S., Kaji, N., Tokeshi, M., & Baba, Y. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2648-5 · Cited by 38
Leveraging the Advantages Offered by Microfluidics to Enhance the Drug Discovery Process
Hawkes, S. Y. F. W., Chapela, M. J. V., & Montembault, M. (2005) · QSAR & Combinatorial Science · doi:10.1002/qsar.200440001 · Cited by 37
Electrospray interfacing of polymer microfluidics to MALDI‐MS
Wang, Y., Zhou, Y., Balgley, B. M., et al. (2005) · Electrophoresis · doi:10.1002/elps.200500127 · Cited by 37
The dynamics of surface acoustic wave‐driven scaffold cell seeding
Bok, M., Li, H., Yeo, L. Y., & Friend, J. R. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22243 · Cited by 36
Self-citationA microfluidic-FCS platform for investigation on the dissociation of Sp1-DNA complex by doxorubicin
Yeh, H., Puleo, C., Lim, T. C., Ho, Y., Giza, P. E., Huang, R. C. C., & Wang, T. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkl787 · Cited by 29
Chowdhury, J., Kagiala, G. V., Pushpakom, S. P., Lauzon, J., Makin, A. J., Atrazhev, A. M., Stickel, A. J., Newman, W. G., Backhouse, C., & Pilarski, L. M. (2007) · Journal of Molecular Diagnostics · doi:10.2353/jmoldx.2007.070014 · Cited by 27
A silicon probe with integrated microheaters for thermal marking and monitoring of neural tissue
Chen, J., & Wise, K. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605437 · Cited by 25
Development of a microplate reader compatible microfluidic device for enzyme assay
Kang, J. H., & Park, J. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.052 · Cited by 24
Agonist-induced calcium response in single human platelets assayed in a microfluidic device
Tran, L., Farinas, J., Ruslim-Litrus, L., Conley, P. B., Muir, C., Munnelly, K., Sedlock, D. M., & Cherbavaz, D. B. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.02.024 · Cited by 22
DNA sequencing by denaturation: experimental proof of concept with an integrated fluidic device
Chen, Y.-J., Roller, E. E., & Huang, X. C. (2010) · Lab on a Chip · doi:10.1039/b921417h · Cited by 14
On-chip HA/SSCP for the detection of hereditary haemochromatosis
Manage, D. P., Zheng, Y., Somerville, M. J., & Backhouse, C. (2005) · Microfluidics and Nanofluidics · doi:10.1007/s10404-005-0045-8 · Cited by 12
Bicompartmental device for dynamic cell coculture: Design, realisation and preliminary results
Ciofani, G., Migliore, A., Raffa, V., Menciassi, A., & Dario, P. (2008) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.105.536 · Cited by 10
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Plasmonics for future biosensors
Brolo, A. G. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.266 · Cited by 1,074
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Metadata
- Authors
- Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2010-11-11
- Volume
- 7
- Issue
- 1
- Pages
- 12-48
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2107941718
- Cited by
- 622
- References
- 235
- FWCI
- 20.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.