Abstract
A facile method is proposed for the deposition of multiwalled carbon nanotube (MWCNT) layers onto microelectrode arrays by means of a microcontact printing technique, leading to the fabrication of MEAs characterized by well defined electrical and morphological properties. Using polydimethyl siloxane stamps, produced from different mold designs, a flexibility of printing is achieved that provides access to microscale, nanostructured electrodes. The thickness of MWCNT layers can be exactly predetermined by evaluating the concentration of the MWCNT solution employed in the process. The electrode morphology is further characterized using laser scanning and scanning electron microscopy. Next, by means of impedance spectroscopy analysis, the MWCNT–electrode contact resistance and MWCNT film resistance is measured, while electrochemical impedance spectroscopy is used to estimate the obtained electrode–electrolyte interface. Structural and electrochemical properties make these electrodes suitable for electrical stimulation and recording of neurons and electrochemical detection of dopamine. MWCNT‐functionalized electrodes show the ability to detect micromolar amounts of dopamine with a sensitivity of 19 nA μm−1. In combination with their biosensing properties, preliminary electrophysiological measurements show that MWCNT microelectrodes have recording properties superior to those of commercial TiN microelectrodes when detecting neuronal electrical activity under long‐term cell‐culture conditions. MWCNT‐functionalized microelectrode arrays fabricated by microcontact printing represent a versatile and multipurpose platform for cell‐culture monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Carbon Nanotube Substrates Boost Neuronal Electrical Signaling
Lovat, V., Pantarotto, D., Lagostena, L., Cacciari, B., Grandolfo, M., Righi, M., Spalluto, G., Prato, M., & Ballerini, L. (2005) · Nano Letters · doi:10.1021/nl050637m · Cited by 648
Self-citation
Cited by
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Energy Harvesting from the Animal/Human Body for Self-Powered Electronics
Dagdeviren, C., Li, Z., & Wang, Z. L. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044517 · Cited by 348
Cramer, T., Chelli, B., Murgia, M., Barbalinardo, M., Bystrenova, E., de Leeuw, D. M., & Biscarini, F. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp44251a · Cited by 87
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“…interface with neurons (Gabay et al., 2005; Wang et al., 2006; Mazzatenta et al., 2007; Keefer et al., 2008; Shein et al., 2009; Bareket-Keren and Hanein, 2012), and further toward neural implants (Webster et al., 2003; Gabriel et al., 2009; Fuchsberger et al., 2011; David-Pur et al., 2014).”
Background
Metadata
- Authors
- Fuchsberger, K., Goff, A. L., Gambazzi, L., Toma, F. M., Goldoni, A., Giugliano, M., Stelzle, M., & Prato, M.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2011-01-18
- Volume
- 7
- Issue
- 4
- Pages
- 524-530
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2050125017
- Cited by
- 46
- References
- 2
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiwalled Carbon‐Nanotube‐Functionalized Microelectrode Arrays Fabricated by Microcontact Printing: Platform for Studying Chemical and Electrical Neuronal Signaling. https://app.cochat.ai/papers/10.1002/smll.201001640
- The paper
- Fuchsberger, K., Goff, A. L., Gambazzi, L., Toma, F. M., Goldoni, A., Giugliano, M., Stelzle, M., & Prato, M. (2011). Multiwalled Carbon‐Nanotube‐Functionalized Microelectrode Arrays Fabricated by Microcontact Printing: Platform for Studying Chemical and Electrical Neuronal Signaling. Small. https://doi.org/10.1002/smll.201001640
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.