The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Colorimetric Detection of Mercury Ions Based on Plasmonic Nanoparticles
Abstract
The development of rapid, specific, cost‐effective, and robust tools in monitoring Hg 2+ levels in both environmental and biological samples is of utmost importance due to the severe mercury toxicity to humans. A number of techniques exist, but the colorimetric assay, which is reviewed herein, is shown to be a possible tool in monitoring the level of mercury. These assays allow transforming target sensing events into color changes, which have applicable potential for in‐the‐field application through naked‐eye detection. Specifically, plasmonic nanoparticle‐based colorimetric assay exhibits a much better propensity for identifying various targets in terms of sensitivity, solubility, and stability compared to commonly used organic chromophores. In this review, recent progress in the development of gold nanoparticle‐based colorimetric assays for Hg 2+ is summarized, with a particular emphasis on examples of functionalized gold nanoparticle systems with oligonucleotides, oligopeptides, and functional molecules. Besides highlighting the current design principle for plasmonic nanoparticle‐based colorimetric probes, the discussions on challenges and the prospect of next‐generation probes for in‐the‐field applications are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Self-citation
Cited by
Plasmon-enhanced optical sensors: a review
Li, M., Cushing, S. K., & Wu, N. (2015) · The Analyst · doi:10.1039/c4an01079e · Cited by 1,011
Detection and Spatial Mapping of Mercury Contamination in Water Samples Using a Smart-Phone
Wei, Q., Nagi, R., Sadeghi, K., Feng, S., Yan, E., Ki, S. J., Caire, R., Tseng, D., & Ozcan, A. (2014) · ACS Nano · doi:10.1021/nn406571t · Cited by 400
Awual, M. R., Hasan, M. M., Eldesoky, G. E., Khaleque, M. A., Rahman, M. M., & Naushad, M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.01.038 · Cited by 398
Lin, T., Zhong, L., Guo, L., Fu, F., & Chen, G. (2014) · Nanoscale · doi:10.1039/c4nr03393k · Cited by 384
Chen, Z., Zhang, Z., Qi, J., You, J., Ma, J., & Chen, L. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129889 · Cited by 319
Self-citation
Metadata
- Authors
- Du, J., Jiang, L., Shao, Q., Liu, X., Marks, R. S., Ma, J., & Chen, X.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2012-09-07
- Volume
- 9
- Issue
- 9-10
- Pages
- 1467-1481
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2142956289
- Cited by
- 289
- References
- 2
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colorimetric Detection of Mercury Ions Based on Plasmonic Nanoparticles. https://app.cochat.ai/papers/10.1002/smll.201200811
- The paper
- Du, J., Jiang, L., Shao, Q., Liu, X., Marks, R. S., Ma, J., & Chen, X. (2013). Colorimetric Detection of Mercury Ions Based on Plasmonic Nanoparticles. Small. https://doi.org/10.1002/smll.201200811
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.