The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Ratiometric Sensor Using Single Chirality Near‐Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring
Open accessAbstract
Advances in the separation and functionalization of single walled carbon nanotubes (SWCNT) by their electronic type have enabled the development of ratiometric fluorescent SWCNT sensors for the first time. Herein, single chirality SWCNT are independently functionalized to recognize either nitric oxide (NO), hydrogen peroxide (H 2 O 2), or no analyte (remaining invariant) to create optical sensor responses from the ratio of distinct emission peaks. This ratiometric approach provides a measure of analyte concentration, invariant to the absolute intensity emitted from the sensors and hence, more stable to external noise and detection geometry. Two distinct ratiometric sensors are demonstrated: one version for H 2 O 2, the other for NO, each using 7,6 emission, and each containing an invariant 6,5 emission wavelength. To functionalize these sensors from SWCNT isolated from the gel separation technique, a method for rapid and efficient coating exchange of single chirality sodium dodecyl sulfate‐SWCNT is introduced. As a proof of concept, spatial and temporal patterns of the ratio sensor response to H 2 O 2 and, separately, NO, are monitored in leaves of living plants in real time. This ratiometric optical sensing platform can enable the detection of trace analytes in complex environments such as strongly scattering media and biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodal optical sensing and analyte specificity using single-walled carbon nanotubes
Heller, D. A., Jin, H., Martinez, B. M., Patel, D., Miller, B. M., Yeung, T.-K., Jena, P. V., Höbartner, C., Ha, T., Silverman, S. K., et al. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2008.369 · Cited by 319
Self-citation
Cited by
Nanoparticle-Based Sustainable Agriculture and Food Science: Recent Advances and Future Outlook
Mittal, D., Kaur, G., Singh, P., Yadav, K., & Ali, S. A. (2020) · Frontiers in Nanotechnology · doi:10.3389/fnano.2020.579954 · Cited by 788
Nano-Biotechnology in Agriculture: Use of Nanomaterials to Promote Plant Growth and Stress Tolerance
Zhao, L., Lu, L., Wang, A., Zhang, H., Huang, M., Wu, H., Xing, B., Wang, Z., & Ji, R. (2020) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.9b06615 · Cited by 745
Nanobiotechnology approaches for engineering smart plant sensors
Giraldo, J. P., Wu, H., Newkirk, G. M., & Kruss, S. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0470-6 · Cited by 596
Self-citationNanoparticle Charge and Size Control Foliar Delivery Efficiency to Plant Cells and Organelles
Hu, P., An, J., Faulkner, M. M., Wu, H., Li, Z., Tian, X., & Giraldo, J. P. (2020) · ACS Nano · doi:10.1021/acsnano.9b09178 · Cited by 515
Self-citationWong, M. H., Misra, R. P., Giraldo, J. P., Kwak, S.-Y., Son, Y., Landry, M. P., Swan, J. W., Blankschtein, D., & Strano, M. S. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04467 · Cited by 338
Self-citation
Metadata
- Authors
- Giraldo, J. P., Landry, M. P., Kwak, S., Jain, R. M., Wong, M. H., Iverson, N. M., Ben‐Naim, M., & Strano, M. S.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2015-05-15
- Volume
- 11
- Issue
- 32
- Pages
- 3973-3984
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2108581465
- Cited by
- 187
- References
- 1
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.