Inhibiting Solid Tumor Growth In Vivo by Non‐Tumor‐Penetrating Nanomedicine
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Nanomedicine (NM) cannot penetrate deeply into solid tumors, which is partly attributed to the heterogeneous microenvironment and high interstitial fluid pressure of solid tumors. To improve NM efficacy, there has been tremendous effort developing tumor‐penetrating NMs by miniaturizing NM sizes or controlling NM surface properties. But progress along the direction of developing tumor penetrating nanoparticle has been slow and improvement of the overall antitumor efficacy has been limited. Herein, a novel strategy of inhibiting solid tumor with high efficiency by dual‐functional, nontumor‐penetrating NM is demonstrated. The intended NM contains 5,6‐dimethylxanthenone‐4‐acetic acid (DMXAA), a vascular‐disrupting agent, and doxorubicin (DOX), a cytotoxic drug. Upon arriving at the target tumor site, sustained release of DMXAA from NMs results in disruption of tumor vessel functions, greatly inhibiting the interior tumor cells by cutting off nutritional supply. Meanwhile, the released DOX kills the residual cells at the tumor exterior regions. The in vivo studies demonstrate that this dual‐functional, nontumor penetrating NM exhibits superior anticancer activity, revealing an alternative strategy of effective tumor growth inhibition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accumulation of sub-100 nm polymeric micelles in poorly permeable tumours depends on size
Cabral, H., Matsumoto, Y., Mizuno, K., Chen, Q., Murakami, M., Kimura, M., Terada, Y., Kano, M. R., Miyazono, K., Uesaka, M., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.166 · Cited by 2,429
Duan, X., & Li, Y. (2013) · Small · doi:10.1002/smll.201201390 · Cited by 926
Nichols, J. W., & Bae, Y. H. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.057 · Cited by 834
Siemann, D. W. (2011) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2010.05.001 · Cited by 611
Cited by
Synthetic polypeptides: from polymer design to supramolecular assembly and biomedical application
Song, Z., Han, Z., Lv, S., Chen, C., Chen, L., Yin, L., & Cheng, J. (2017) · Chem. Soc. Rev. · doi:10.1039/c7cs00460e · Cited by 407
Self-citationFentahun Darge, H., Yibru Hanurry, E., Simegniew Birhan, Y., Worku Mekonnen, T., Tizazu Andrgie, A., Chou, H.-Y., Lai, J.-Y., & Tsai, H.-C. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126879 · Cited by 81
Qiu, M., Ouyang, J., Sun, H., Meng, F., Cheng, R., Zhang, J., Cheng, L., Lan, Q., Deng, C., & Zhong, Z. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b10533 · Cited by 45
Zhao, B., Dong, K., Lin, M., Dong, G., Shan, S., Lawson, T., Yan, L., Zhang, W., Shi, B., Chou, S., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800377 · Cited by 18
Metadata
- Authors
- Lv, S., Tang, Z., Song, W., Zhang, D., Li, M., Liu, H., Cheng, J., Zhong, W., & Chen, X.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2017-01-12
- Volume
- 13
- Issue
- 12
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2576059785
- Cited by
- 47
- References
- 4
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.