The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Nitrogen‐Doped Single Graphene Fiber with Platinum Water Dissociation Catalyst for Wearable Humidity Sensor
Abstract
Humidity sensors are essential components in wearable electronics for monitoring of environmental condition and physical state. In this work, a unique humidity sensing layer composed of nitrogen‐doped reduced graphene oxide (n RGO) fiber on colorless polyimide film is proposed. Ultralong graphene oxide (GO) fibers are synthesized by solution assembly of large GO sheets assisted by lyotropic liquid crystal behavior. Chemical modification by nitrogen‐doping is carried out under thermal annealing in H 2(4%)/N 2(96%) ambient to obtain highly conductive n RGO fiber. Very small (≈2 nm) Pt nanoparticles are tightly anchored on the surface of the n RGO fiber as water dissociation catalysts by an optical sintering process. As a result, n RGO fiber can effectively detect wide humidity levels in the range of 6.1–66.4% relative humidity (RH). Furthermore, a 1.36‐fold higher sensitivity (4.51%) at 66.4% RH is achieved using a Pt functionalized n RGO fiber (i.e., Pt‐n RGO fiber) compared with the sensitivity (3.53% at 66.4% RH) of pure n RGO fiber. Real‐time and portable humidity sensing characteristics are successfully demonstrated toward exhaled breath using Pt‐n RGO fiber integrated on a portable sensing module. The Pt‐n RGO fiber with high sensitivity and wide range of humidity detection levels offers a new sensing platform for wearable humidity sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, H., Maiyalagan, T., & Wang, X. (2012) · ACS Catalysis · doi:10.1021/cs200652y · Cited by 3,618
Choi, S.-J., Kim, S.-J., & Kim, I.-D. (2016) · NPG Asia Materials · doi:10.1038/am.2016.150 · Cited by 128
Self-citation
Cited by
Liu, L., Chen, W., Zhang, H., Wang, Q., Guan, F., & Yu, Z. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201905197 · Cited by 699
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Zhao, X., Wang, L.-Y., Tang, C.-Y., Zha, X.-J., Liu, Y., Su, B.-H., Ke, K., Bao, R.-Y., Yang, M.-B., & Yang, W. (2020) · ACS Nano · doi:10.1021/acsnano.0c03391 · Cited by 511
Recent advances in humidity sensors for human body related humidity detection
Duan, Z., Jiang, Y., & Tai, H. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc04180k · Cited by 365
Multifunctional Flexible Humidity Sensor Systems Towards Noncontact Wearable Electronics
Lu, Y., Yang, G., Shen, Y., Yang, H., & Xu, K. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00895-5 · Cited by 320
Metadata
- Authors
- Choi, S., Yu, H., Jang, J., Kim, M., Kim, S., Jeong, H. S., & Kim, I.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2018-02-14
- Volume
- 14
- Issue
- 13
- Pages
- e1703934-e1703934
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2791200096
- Cited by
- 159
- References
- 2
- FWCI
- 8.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nitrogen‐Doped Single Graphene Fiber with Platinum Water Dissociation Catalyst for Wearable Humidity Sensor. https://app.cochat.ai/papers/10.1002/smll.201703934
- The paper
- Choi, S., Yu, H., Jang, J., Kim, M., Kim, S., Jeong, H. S., & Kim, I. (2018). Nitrogen‐Doped Single Graphene Fiber with Platinum Water Dissociation Catalyst for Wearable Humidity Sensor. Small. https://doi.org/10.1002/smll.201703934
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.