Cited by 128Gas Sensing Nanomaterials and SensorsGraphene research and applicationsAdvanced Sensor and Energy Harvesting Materials

Ultrafast optical reduction of graphene oxide sheets on colorless polyimide film for wearable chemical sensors

Open access
Choi, Seon-Jin, Kim, Sang-Joon, Kim, Il-Doo·2016·NPG Asia Materials

Abstract

Optically reduced graphene oxide (RGO) sheets were produced on a thermally stable and highly transparent colorless polyimide (CPI) substrate by irradiating intense pulsed light (IPL) on a GO-coated CPI film. These RGO sheets can be used as flexible gas sensing layers for wearable applications. Ultrafast IPL irradiation formed RGO sheets on the CPI film within 4 msec without any damage on the plastic substrate. The IPL-induced RGO (IPL-RGO) sheets exhibited dramatically improved chemical sensing performance toward H2S, C2H5OH, and H2, while the pristine GO sheets did not show any gas responses. In addition, consistent sensing properties were maintained even after the IPL-RGO sheets on the CPI film were mechanically deformed for 104 bending cycles. The gas responses of an IPL-RGO sensor toward H2S, C2H5OH and H2 were clearly distinguished by pattern recognition based on principal component analysis. Moreover, we successfully integrated our IPL-RGO sensor on a flexible printed circuit board with wireless Bluetooth communication and demonstrated outstanding sensing properties for potential applications in environmental and healthcare monitoring. A bendable, Bluetooth-connected device that senses environmental gases can be fabricated in just milliseconds using intense laser light. The rigid silicon substrates used to construct most chemical gas sensors pose problems for applications such as wearable environmental monitors. Il-Doo Kim and colleagues from the Korea Advanced Institute of Science and Technology have now developed an alternative gas-sensing platform based on graphene oxide sheets and transparent, flexible polymers. The team synthesized a colorless polyimide film with high thermal stability, coated it with graphene oxide, and then used short bursts of broad-spectrum laser light to transform the graphene oxide sheets into a reduced graphene oxide sheets sensitive to gases such as ethanol, hydrogen, and hydrogen sulfide. Integration into a wireless, watch-type device revealed the gas sensor retained high sensitivity after more than 10,000 bending cycles. Ultrafast reduction of graphene oxide sheets was achieved by intense pulsed light irradiation on a highly transparent and thermally stable polyimide substrate. The obtained reduced graphene sheets exhibited improved chemical sensing characteristics, which are promising in wearable chemical sensors for real-time environmental monitoring.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/am.2016.150

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • rGO was capable of detecting various gases including H2, H2S, and ethanol.

    “For example, rGO was capable of detecting various gases including H 2 , H 2 S, and ethanol.[45]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [45]

  • The rGO sensor can be integrated into a watch-type wearable gas monitor.

    “The sensor can be integrated into a watch-type wearable gas monitor, as shown in Figure 6g.”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [45]

  • Wireless transmission capability can be enabled by integrating an antenna or a Bluetooth module.

    “Wireless transmission capability can be enabled by integrating an antenna [169,175,176] or a Bluetooth module.[42,45,119,175]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [45]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Choi, S.-J., Kim, S.-J., & Kim, I.-D.
Affiliations
Korea Advanced Institute of Science and Technology (KR)
Corresponding author
Kim, Il-Doo
Venue
NPG Asia Materials
Published
2016-09
Volume
8
Issue
9
Pages
e315-e315
ISSN
  • 1884-4049 (ISSN-L)
  • 1884-4057
OpenAlex
W2522305554
Cited by
128
References
48
Citations by year
2026: 9 · 2025: 12 · 2024: 13 · 2023: 15 · 2022: 16 · 2021: 10 · 2020: 14 · 2019: 16 · 2018: 12 · 2017: 11
FWCI
6.00
Type
journal article
Language
en
Open access
Locations
NPG Asia Materials (publishedVersion, cc-by)
Funders
  • National Research Foundation (2016R1A5A1009926)
  • Ministry of Science, ICT and Future Planning (2016R1A5A1009926)
  • Korea Institute of Machinery and Materials
  • National Research Foundation of Korea (2016R1A5A1009926)
  • National Research Council of Science and Technology
  • KAIST Wearable Platform Material Technology Center (2016R1A5A1009926)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Materials Science › Materials Chemistry › Graphene research and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
reduced graphene oxide, graphene oxide, intense pulsed light, wearable gas sensors, hydrogen sulfide detection, ethanol detection, hydrogen detection, mechanical durability, environmental monitoring, healthcare monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review