The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Smart Patch with On‐Demand Detachable Adhesion for Bioelectronics
Abstract
A smart ionic skin patch with on‐demand detachable adhesion has been developed as human–machine interface for physiological signal monitoring. In spite of the multifunctions demonstrated by existing ionic skin, it is still difficult to distinguish different signals simultaneously. Moreover, the secondary damages to the tissues are often overlooked when the adhesive materials are removing from the wound. Herein, a multifunctional biomimetic hydrogel with temperature, mechanical, electrical, and pH response is developed. This hydrogel is designed by in situ polymerizing of hydrophilic anion monomers in a natural cationic polysaccharide to construct multifunctional biomimetic ionic channel. Due to the reversible physical cross‐linked network and thermosensitivity, the mechanical properties, adhesion, and visual effect of the hydrogel can be tuned by changing hydrogen bonding density via phase transition, thus making it an excellent biosafe material for wearable device. The hydrogel is utilized as skin patch intended for monitoring physiological signals stimulated by physical and chemical changes involving pressure, temperature, pH value, and electrocardiograph. Especially, this ionic skin patch can recognize temperature change signals precisely either in broad or extremely narrow temperature range. This smart skin patch can even recognize the pressure and temperature signals in real time and differentiate the signals simultaneously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An, B. W., Heo, S., Ji, S., Bien, F., & Park, J.-U. (2018) · Nature Communications · doi:10.1038/s41467-018-04906-1 · Cited by 426
Stretchable E‐Skin Apexcardiogram Sensor
You, I., Kim, B., Park, J., Koh, K., Shin, S., Jung, S., & Jeong, U. (2016) · Advanced Materials · doi:10.1002/adma.201600720 · Cited by 213
Highly Precise Multifunctional Thermal Management-Based Flexible Sensing Sheets
Xu, K., Lu, Y., Yamaguchi, T., Arie, T., Akita, S., & Takei, K. (2019) · ACS Nano · doi:10.1021/acsnano.9b07805 · Cited by 86
Cited by
Jiang, Y., Trotsyuk, A. A., Niu, S., Henn, D., Chen, K., Shih, C.-C., Larson, M. R., Mermin-Bunnell, A. M., Mittal, S., Lai, J.-C., et al. (2023) · Nature Biotechnology · doi:10.1038/s41587-022-01528-3 · Cited by 559
Fu, Y., Shi, Y., Wang, L., Zhao, Y., Wang, R., Li, K., Zhang, S., Zha, X., Wang, W., Zhao, X., et al. (2023) · Advanced Science · doi:10.1002/advs.202206771 · Cited by 314
Yao, P., Bao, Q., Yao, Y., Xiao, M., Xu, Z., Yang, J., & Liu, W. (2023) · Advanced Materials · doi:10.1002/adma.202300114 · Cited by 308
Pi, M., Qin, S., Wen, S., Wang, Z., Wang, X., Li, M., Lu, H., Meng, Q., Cui, W., & Ran, R. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202210188 · Cited by 282
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64
Metadata
- Authors
- Shi, X., & Wu, P.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2021-06-08
- Volume
- 17
- Issue
- 26
- Pages
- e2101220-e2101220
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W3171142841
- Cited by
- 236
- References
- 3
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Smart Patch with On‐Demand Detachable Adhesion for Bioelectronics. https://app.cochat.ai/papers/10.1002/smll.202101220
- The paper
- Shi, X., & Wu, P. (2021). A Smart Patch with On‐Demand Detachable Adhesion for Bioelectronics. Small. https://doi.org/10.1002/smll.202101220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.