CoChat

In Vivo Surface‐Enhanced Transmission Raman Spectroscopy under Maximum Permissible Exposure: Toward Photosafe Detection of Deep‐Seated Tumors

The DOI matches its Crossref record; 48 of the 49 references it cites were found in a registry or an index.

Abstract

The detection of deep‐seated lesions is of great significance for biomedical applications. However, due to the strong photon absorption and scattering of biological tissues, it is challenging to realize in vivo deep optical detections, particularly for those using the safe laser irradiance below clinical maximum permissible exposure (MPE). In this work, the combination of ultra‐bright surface‐enhanced Raman scattering (SERS) nanotags and transmission Raman spectroscopy (TRS) is reported to achieve the non‐invasive and photosafe detection of “phantom” lesions deeply hidden in biological tissues, under the guidance of theoretical calculations showing the importance of SERS nanotags’ brightness and the expansion of laser beam size. Using a home‐built TRS system with a laser power density of 0.264 W cm−2 (below the MPE criteria), we successfully demonstrated the detection of SERS nanotags through up to 14‐cm‐thick ex vivo porcine tissues, as well as in vivo imaging of “phantom” lesions labeled by SERS nanotags in a 1.5‐cm‐thick unshaved mouse under MPE. This work highlights the potential of transmission Raman‐guided identification and non‐invasive imaging toward clinically photosafe cancer diagnoses.

Overview

Integrity signals

Registry

Crossref · 10.1002/smtd.202201334

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 48 references

Research works printed but not linked: 3

  1. Raiti P., 2019, Bsava Manual of Reptiles, 133
  2. Fryar C. D., 2016, Vital Health Stat., 3, 1
  3. Tseng J. C., 2015, Technical Note, Pre‐Clinical in Vivo Imaging

Cited by

Metadata

Authors
Zhang, Y., Chen, R., Liu, F., Miao, P., Lin, L., & Ye, J.
Affiliations
Shanghai Jiao Tong University (CN)
Corresponding author
  • Lin, Li
  • Ye, Jian
Venue
Small Methods
Publisher
Wiley
Published
2022-12-26
Volume
7
Issue
2
Pages
e2201334-e2201334
ISSN
2366-9608 (ISSN-L)
OpenAlex
W4312198041
Cited by
52
References
49
Citations by year
2026: 12 · 2025: 11 · 2024: 20 · 2023: 9
FWCI
4.42
Type
journal article
Language
en
Open access
closed
Locations
  • Small Methods (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (81871401, 81901786, 82272054)
  • Science and Technology Commission of Shanghai Municipality (21511102100)
  • Shanghai Jiao Tong University (YG2019QNA28, YG2022QN006)
  • Shanghai Key Laboratory of Gynecologic Oncology
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
surface-enhanced Raman scattering, transmission Raman spectroscopy, maximum permissible exposure, SERS nanotags, in vivo imaging, porcine tissue, mouse tumor model, cancer diagnosis, non-invasive imaging
MeSH terms
Animals, Gold, Light, Neoplasms, Spectrum Analysis, Raman, Swine, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.