The DOI matches its Crossref record.
Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy
Abstract
We describe a simple methodology for the effective retrieval of Raman spectra of subsurface layers in diffusely scattering media. The technique is based on the collection of Raman scattered light from surface regions that are laterally offset away from the excitation laser spot on the sample. The Raman spectra obtained in this way exhibit a variation in relative spectral intensities of the surface and subsurface layers of the sample being investigated. The data set is processed using a multivariate data analysis to yield pure Raman spectra of the individual sample layers, providing a method for the effective elimination of surface Raman scatter. The methodology is applicable to the retrieval of pure Raman spectra from depths well in excess of those accessible with conventional confocal microscopy. In this first feasibility study we have differentiated between surface and subsurface Raman signals within a diffusely scattering sample composed of two layers: trans-stilbene powder beneath a 1 mm thick over-layer of PMMA (poly(methyl methacrylate)) powder. The improvement in contrast of the subsurface trans-stilbene layer without numerical processing was 19 times. The potential applications include biomedical subsurface probing of specific tissues through different overlying tissues such as assessment of bone quality through skin, providing an effective noninvasive means of screening for bone degeneration, other skeletal disease diagnosis, and dermatology studies, as well as materials and catalyst research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Guo, S., Popp, J., & Bocklitz, T. (2021) · Nature Protocols · doi:10.1038/s41596-021-00620-3 · Cited by 361
Contributions of Raman spectroscopy to the understanding of bone strength
Mandair, G. S., & Morris, M. D. (2015) · BoneKEy Reports · doi:10.1038/bonekey.2014.115 · Cited by 358
Self-citationSurface enhanced spatially offset Raman spectroscopic (SESORS) imaging – the next dimension
Stone, N., Kerssens, M., Lloyd, G. R., Faulds, K., Graham, D., & Matousek, P. (2011) · Chemical Science · doi:10.1039/c0sc00570c · Cited by 183
Self-citationIn Vitro and In Vivo SERS Biosensing for Disease Diagnosis
Moore, T. J., Moody, A. S., Payne, T. D., Sarabia, G. M., Daniel, A. R., & Sharma, B. (2018) · Biosensors · doi:10.3390/bios8020046 · Cited by 161
Metadata
- Authors
- Matousek, P., Clark, I. P., Draper, E. R. C., Morris, M. D., Goodship, A. E., Everall, N., Towrie, M., Finney, W. F., & Parker, A. W.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2005-04
- Volume
- 59
- Issue
- 4
- Pages
- 393-400
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2021448456
- Cited by
- 548
- References
- 0
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy. https://app.cochat.ai/papers/10.1366/0003702053641450
- The paper
- Matousek, P., Clark, I. P., Draper, E. R. C., Morris, M. D., Goodship, A. E., Everall, N., Towrie, M., Finney, W. F., & Parker, A. W. (2005). Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy. Applied Spectroscopy. https://doi.org/10.1366/0003702053641450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.