CoChat

Negative stiffness friction damping for seismically isolated structures

Open access
Iemura, Hirokazu, Igarashi, Akira, Pradono, Mulyo Harris, Kalantari, Afshin · 2006 · Structural Control and Health Monitoring
Cited by 75

The DOI matches its Crossref record.

Abstract

Research shown in this paper is focused on the development of an autonomous semi-active control laws as simplified semi-active control algorithms for seismic response reduction. The strategy of the methods is to produce desirable hysteretic loops to absorb as much energy as possible by semi-active devices. The control method requires information only on the device's displacement and velocity. The hysteretic loops produced by the semi-active control herein provide energy absorption capacity similar to those by friction dampers, while minimizing the disadvantages of the friction dampers, such as residual displacement after strong earthquakes and the generation of high-frequency in the damping forces. The structure used for numerical simulation is the benchmark problem for control of base-isolated buildings. The results show that the simplified control strategy is effective for a variety of ground motions. Copyright © 2005 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.111

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Iemura, H., Igarashi, A., Pradono, M. H., & Kalantari, A.
Venue
Structural Control and Health Monitoring
Published
2006
Volume
13
Issue
2-3
Pages
775-791
ISSN
  • 1545-2255 (ISSN-L)
  • 1545-2263
OpenAlex
W2164599504
Cited by
75
References
0
FWCI
4.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.