The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Vision-based multipoint displacement measurement for structural health monitoring: Vision-Based Displacement Measurement for SHM
Abstract
A novel noncontact vision sensor for simultaneous measurement of structural displacements at multiple points using one camera is developed based on two advanced template matching techniques: the upsampled cross correlation (UCC) and the orientation code matching (OCM). While existing studies on vision sensors are mostly focused on the time-domain performance evaluation, this study investigates the performance in both time and frequency domains through a shaking table test of a three-story frame structure, in which the displacements at all the floors are measured by using one camera to track either high-contrast artificial targets or low-contrast natural targets on the structural surface such as bolts and nuts. Excellent agreements are observed between the displacements measured by the single camera and those measured by high-performance laser displacement sensors. The results of structural modal analysis based on the measurements by the vision sensor and reference accelerometers also agree well. Moreover, the identified modal parameters are used to update the finite element model of the structure, demonstrating the potential of the vision sensor for structural health monitoring applications. This study further examines the robustness of the proposed vision sensor against ill environmental conditions such as dim light, background image disturbance, and partial template occlusion, which is important for future implementation in the field. Significant advantages of the proposed vision sensor include its low cost (a single camera to remotely measure structural displacements at multiple points without installing artificial targets) and flexibility to extract structural displacements at any point from a single measurement. Copyright © 2015 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficient subpixel image registration algorithms
Guizar-Sicairos, M., Thurman, S. T., & Fienup, J. R. (2008) · Optics Letters · doi:10.1364/ol.33.000156 · Cited by 1,905
A Vision-Based Sensor for Noncontact Structural Displacement Measurement
Feng, D., Feng, M., Ozer, E., & Fukuda, Y. (2015) · Sensors · doi:10.3390/s150716557 · Cited by 452
Self-citationDebella-Gilo, M., & Kääb, A. (2010) · Remote Sensing of Environment · doi:10.1016/j.rse.2010.08.012 · Cited by 363
Ribeiro, D., Calçada, R., Ferreira, J., & Martins, T. (2014) · Engineering Structures · doi:10.1016/j.engstruct.2014.04.051 · Cited by 272
Vibration Monitoring of Multiple Bridge Points by Means of a Unique Vision-Based Measuring System
Busca, G., Cigada, A., Mazzoleni, P., & Zappa, E. (2013) · Experimental Mechanics · doi:10.1007/s11340-013-9784-8 · Cited by 218
Fukuda, Y., Feng, M. Q., Narita, Y., Kaneko, S., & Tanaka, T. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2273309 · Cited by 202
Self-citationVision-based monitoring system for evaluating cable tensile forces on a cable-stayed bridge
Kim, S., Jeon, B.-G., Kim, N.-S., & Park, J.-C. (2013) · Structural Health Monitoring · doi:10.1177/1475921713500513 · Cited by 173
Cost-effective vision-based system for monitoring dynamic response of civil engineering structures
Fukuda, Y., Feng, M. Q., & Shinozuka, M. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.360 · Cited by 172
Self-citationModel Updating of Railway Bridge Using In Situ Dynamic Displacement Measurement under Trainloads
Feng, D., & Feng, M. Q. (2015) · Journal of Bridge Engineering · doi:10.1061/(asce)be.1943-5592.0000765 · Cited by 163
Self-citationNontarget Image-Based Technique for Small Cable Vibration Measurement
Ji, Y., & Chang, C.-C. G. (2007) · Journal of Bridge Engineering · doi:10.1061/(asce)1084-0702(2008)13:1(34 · Cited by 152
Cited by
Advances in Computer Vision-Based Civil Infrastructure Inspection and Monitoring
Spencer, B. F., Hoskere, V., & Narazaki, Y. (2019) · Engineering · doi:10.1016/j.eng.2018.11.030 · Cited by 1,194
Feng, D., & Feng, M. Q. (2018) · Engineering Structures · doi:10.1016/j.engstruct.2017.11.018 · Cited by 782
Self-citationAzimi, M., Eslamlou, A., & Pekcan, G. (2020) · Sensors · doi:10.3390/s20102778 · Cited by 769
A literature review of next-generation smart sensing technology in structural health monitoring
Sony, S., Laventure, S., & Sadhu, A. (2019) · Structural Control and Health Monitoring · doi:10.1002/stc.2321 · Cited by 606
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23042204 · Cited by 492
Metadata
- Authors
- Feng, D., & Feng, M. Q.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2015-11-05
- Volume
- 23
- Issue
- 5
- Pages
- 876-890
- ISSN
- 1545-2255 (ISSN-L)
- OpenAlex
- W1916064950
- Cited by
- 266
- References
- 18
- FWCI
- 18.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vision-based multipoint displacement measurement for structural health monitoring: Vision-Based Displacement Measurement for SHM. https://app.cochat.ai/papers/10.1002/stc.1819
- The paper
- Feng, D., & Feng, M. Q. (2016). Vision-based multipoint displacement measurement for structural health monitoring: Vision-Based Displacement Measurement for SHM. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.1819
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.