Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Investigation of dynamic properties of long-span cable-stayed bridges based on one-year monitoring data under normal operating condition

Mao, Jian-Xiao, Wang, Hao, Feng, Dong-Ming, Tao, Tian-You, Zheng, Wen-Zhi · 2018 · Structural Control and Health Monitoring

Abstract

Environmental factors, such as temperature, traffic, and wind, play an important role on the variations of dynamic properties of long-span cable-stayed bridges. The dynamic characteristics of Sutong Cable-Stayed Bridge (SCB), including acceleration and strain responses as well as modal frequencies, are investigated using one-year continuous monitoring data under operating conditions by the structural health monitoring system. The in situ wind characteristics and structural temperature behavior of SCB are also analyzed. More than 99% of the wind speed values are smaller than 16 m/s; and the largest temperature variation of the main girder exceeds 60 °C. Besides, acceleration and strain, root mean square (RMS) data are both normalized using the Z-score standardization method. Relation analysis between the normalized acceleration and strain RMS values is conducted based on the time-history comparison and linear least square fitting. Results show that both of the processed acceleration and strain RMS values could properly describe the variation trend of the traffic load, although variation amplitudes of the two normalized parameters differ from each other. In addition, one-year continuous modal frequencies of SCB are identified using Hilbert–Huang transform method. Variability analysis of the structural modal frequencies due to environmental temperature and operational traffics is then conducted. Results show that temperature is the most important environmental factor for vertical and torsional modal frequencies. The traffic load is the second critical factor especially for the fundamental vertical frequency of SCB. Research results could provide references for damage detection and safety evaluation for similar long-span cable-stayed bridges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.2146

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Mao, J.-X., Wang, H., Feng, D.-M., Tao, T.-Y., & Zheng, W.-Z.
Venue
Structural Control and Health Monitoring
Publisher
Wiley
Published
2018-02-08
Volume
25
Issue
5
Pages
e2146
ISSN
1545-2255 (ISSN-L)
OpenAlex
W2792675839
Cited by
163
References
2
FWCI
19.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigation of dynamic properties of long-span cable-stayed bridges based on one-year monitoring data under normal operating condition. https://app.cochat.ai/papers/10.1002/stc.2146
The paper
Mao, J.-X., Wang, H., Feng, D.-M., Tao, T.-Y., & Zheng, W.-Z. (2018). Investigation of dynamic properties of long-span cable-stayed bridges based on one-year monitoring data under normal operating condition. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.2146

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.