Fundamental mechanism of earthquake response reduction in building structures with inertial dampers
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Fundamental mechanisms of earthquake response reduction in building structures with inertial mass dampers are investigated. The inertial mass damper is effective with respect to relative acceleration between two nodes. The influence of inertial mass dampers on the ground-motion input can be expressed by the influence coefficient vector to be multiplied on the ground-motion acceleration in the right-hand side of the equations of motion. It is shown that, when an inertial mass damper is taken out from one story, the component of the influence coefficient vector above that story becomes 1. This means that, if an inertial mass damper is taken out from one story, the inertial mass dampers above that story do not influence the input acceleration above that story. This observation is supported by the closed-form expression of the influence coefficient vector. The mechanism of earthquake response reduction is also discussed from the viewpoint of earthquake input energy. It is shown that the earthquake input energy under an acceleration input with a constant Fourier spectrum depends on the influence coefficient vector. Finally, the characteristics of earthquake response reduction via inertial mass dampers are presented for three recorded ground motions. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of mechanical networks: the inerter
Smith, M. C. (2002) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2002.803532 · Cited by 1,828
Cited by
Using an inerter‐based device for structural vibration suppression
Lazar, I. F., Neild, S. A., & Wagg, D. J. (2014) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2390 · Cited by 799
An enhanced base isolation system equipped with optimal tuned mass damper inerter (tmdi)
De Domenico, D., & Ricciardi, G. (2018) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.3011 · Cited by 473
Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
Giaralis, A., & Taflanidis, A. A. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2082 · Cited by 328
De Domenico, D., & Ricciardi, G. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2234 · Cited by 169
Gonzalez-Buelga, A., Lazar, I. F., Jiang, J. Z., Neild, S. A., & Inman, D. J. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.1879 · Cited by 136
“In [10], the advantages of using inerters when protecting buildings from earthquake excitation were examined.”
BackgroundGiaralis, A., & Taflanidis, A. A. (2015) · The University of British Columbia · doi:10.14288/1.0076257 · Cited by 24
“Note that in deriving the previous two equations the inerter is taken as weightless, similarly to the spring and to the dashpot, and, therefore, and it does not attract any horizontal seismic inertial force (see also Takewaki et al. 2012, and Marian and Giaralis 2014).”
Background
Metadata
- Authors
- Takewaki, I., Murakami, S., Yoshitomi, S., & Tsuji, M.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2011-04-04
- Volume
- 19
- Issue
- 6
- Pages
- 590-608
- ISSN
- 1545-2255 (ISSN-L)
- OpenAlex
- W1974000816
- Cited by
- 129
- References
- 1
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.