Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings
Open accessAbstract
An arrangement of tuned mass dampers, termed coupled tuned mass dampers (CTMDs) has been introduced, where a mass is connected by translational springs and viscous dampers in an eccentric manner. The CTMD has coupled modes of lateral and rotational vibration, which have been utilized to control coupled lateral and torsional vibrations of asymmetric buildings. An efficient control strategy has been presented in this context to control displacements as well as acceleration responses of asymmetric buildings having asymmetry in both plan and elevation. The building is idealized as a simplified three-dimensional model with two translational and a rotational degrees of freedom for each floor. The principles of rigid body transformation have been incorporated to account for eccentricity between center of mass and center of rigidity. A nondominated sorting genetic algorithm (GA) has been used for solving the multi-objective optimization problem. Tuning of optimum locations of TMDs and their parameters have been done from the multiple pareto-optimal solutions obtained simultaneously. Comparative studies of performance of CTMD with conventional TMDs and bi-directional TMDs have been presented. It has been observed that CTMDs are more effective and robust in controlling coupled lateral and torsional vibrations of asymmetric buildings. The optimal locations have been observed to be reasonably compact and practically implementable for CTMDs. Copyright © 2005 John Wiley & Sons, Ltd.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Parametric study and simplified design of tuned mass dampers
Rana, R., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00078-3 · Cited by 651 · see citing works
Flagged first, then by citations
Research works printed but not linked: 16
- Xu K, Igusa T. Dynamic characteristics of multiple substructures with closely spaced frequencies. Earthquake Engineering and Structural Dynamics 1992; 21:1059-1070.
- Yamaguchi H, Harnpornchai N. Fundamental characteristics of multiple tuned mass dampers for suppressing harmonically forced oscillations. Earthquake Engineering and Structural Dynamics 1993; 22:51-61.
- Abe M, Fujino Y. Dynamic characteristics of multiple tuned mass dampers and some design formulas. Earthquake Engineering and Structural Dynamics 1994; 23:813-835.
- Joshi AS, Jangid RS. Optimum parameters of multiple tuned mass dampers for base excited damped systems. Journal of Sound and Vibration 1997; 202(5):657-667.
- Hadi MNS, Arfiadi Y. Optimum design of absorber for MDOF structures. Journal of Structural Engineering (ASCE) 1998; 124(11):1272-1280.
- Singh S, Dutta TK. Open-closed-loop linear control of building frames under seismic excitation. Journal of Structural Engineering (ASCE) 1998; 124(1):43-51.
- Chen G, Wu J. Optimal placement of multiple tune mass dampers for seismic structures. Journal of Structural Engineering (ASCE) 2001; 127(9):1054-1062.
- Park J, Reed D. Analysis of uniformly distributed mass dampers under harmonic and earthquake excitation. Engineering Structures 2001; 23:802-814.
- Singh MP, Singh S, Moreschi LM. Tuned mass dampers for response control of torsional buildings. Earthquake Engineering and Structural Dynamics 2002; 31:749-769.
- Copyright # 2005 John Wiley & Sons, Ltd. Struct. Control Health Monit. 2006; 13:897-916
- COUPLED TUNED MASS DAMPERS 915 15452263, 2006, 5, Downloaded from https://onlinelibrary.wiley.com/doi/10.1002/stc.64 by Mount Vernon Nazarene University, Wiley Online Library on [29/08/2026]. See the Terms and Conditions (https://onlinelibrary.wiley.com/terms-and-conditions) on Wiley Online Library for rules of use; OA articles are governed by the applicable Creative Commons License · DOI
- Ahlawat AS, Ramaswamy A. Multi-objective optimal absorber system for torsionally coupled seismically excited structures. Engineering Structures 2003; 25:941-950.
- Hajela P, Lin CY. Genetic search strategies in multi-criterion optimal design. Structural Optimization 1992; 4: 99-107.
- Fonseca CM, Fleming PJ. Genetic algorithms for multi-objective optimization: formulation, discussion and generalization. Proceedings of the 5th International Conference on Genetic Algorithms, Los Altos, 1993; 416-423.
- Goldberg DE. Genetic Algorithms in Search, Optimization, and Machine Learning. Addison-Wesley, 2000.
- Copyright # 2005 John Wiley & Sons, Ltd. Struct. Control Health Monit. 2006; 13:897-916
Cited by
Sorted by citations
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 545 · see citing works
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138 · see citing works
“Examples of such systems include a structure equipped with distributed viscoelastic dampers and an active tuned mass damper on or near the top floor; or a base-isolated structure with actuators that are actively controlled to enhance performance [14].”
Background
- Authors
- Desu, N. B., Deb, S. K., & Dutta, A.
- Affiliations
- Indian Institute of Technology Guwahati (IN)
- Corresponding author
- Dutta, Anjan
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2006
- Volume
- 13
- Issue
- 5
- Pages
- 897-916
- ISSN
- 1545-2255 (ISSN-L)
- 1545-2263
- OpenAlex
- W2056032395
- Cited by
- 84
- References
- 1
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 8 · 2020: 6 · 2019: 9 · 2018: 7 · 2017: 9 · 2016: 4 · 2015: 8 · 2014: 5 · 2013: 3
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Structural Control and Health Monitoring (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic and Structural Analysis of Tall Buildings
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Vibration Analysis
- Keywords
- tuned mass damper, asymmetric buildings, torsional vibration control, rigid transformation, multi-objective optimization, non-dominated sorting genetic algorithm, damper placement optimization, 3D building model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review