Experimental research on interfacial bonding performance of high‐strength steel pipe and surrounding concrete/grout for assembled composite columns

Zhu, Zhangfeng, Wang, Jun · 2023 · Structural Concrete

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Abstract High‐strength steel pipe joints are proposed for assembled composite columns. The steel pipe extends into the upper and lower prefabricated columns and is anchored by poured concrete or grout to realize the connection of the prefabricated columns. Bonding performance of high‐strength steel pipe and surrounding concrete/grout is critical to the joint reliability. Steel pipe push‐out test was carried out, considering parameters of steel pipe section specification, bonding length, bonding material, and outer wall treatment of the steel pipe. Comparative analysis of measured load–displacement/slip curves and calculated bond strength were conducted. Bonding length of 600 mm could provide sufficient bond strength. Increasing bonding length could delay the slippage, but the bond strength decreased. High‐strength grout significantly increased the peak load size. The slenderness ratio and diameter–thickness ratio of the steel pipe had no obvious influence on the bonding performance. Steel pipe with D114*25 section obtained higher bonding strength with smaller ratio of bonding area to cross‐sectional area. Spiral ribs welded to the outer wall of the steel pipe could effectively improve the bonding strength and delay the interface slip. With easy construction and reliable performance, spiral ribs were recommended to be applied in prRactical projects.

Overview

Integrity signals

Registry

Crossref · 10.1002/suco.202201200

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 21 references

Research works printed but not linked: 5

  1. Arabnejad KhanoukiMM Ramli SulongNH ShariatiM.Investigation of seismic behaviour of composite structures with concrete filled square steel tubular (CFSST) column by push‐over and time‐history analyses. In: Proceedings of the 4th international conference on steel composite structures July 21–23 Sydney Australia.2010.
  2. Commission of European Communities, 2004, Design of composite steel and concrete structures‐part1‐1: general rules and rules for buildings: EUROCODE 4 (EC4)
  3. British Standard Institute, 2005, Steel concrete and composite bridges‐part 5: code of practice for the design of composite bridges: BS 5400‐5
  4. Standards Australia, 2004, Bridge design part 6: steel and composite construction: AS 5100.6
  5. American Institute of Steel Construction, 2016, Specification for structural steel buildings: ANSI/AISC 360‐16

Cited by

See all 2

Metadata

Authors
Zhu, Z., & Wang, J.
Affiliations
Nanjing Tech University (CN)
Corresponding author
Zhu, Zhangfeng
Venue
Structural Concrete
Publisher
Wiley
Published
2023-08-28
Volume
24
Issue
6
Pages
7103-7115
ISSN
  • 1464-4177 (ISSN-L)
  • 1751-7648
OpenAlex
W4386253583
Cited by
2
References
21
Citations by year
2025: 1 · 2024: 1
FWCI
0.23
Type
journal article
Language
en
Open access
closed
Locations
Structural Concrete (publishedVersion)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
  • Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Materials Analysis
Keywords
high-strength steel pipe, steel-concrete bond, prefabricated columns, bond strength, bond lengths, spiral ribs, interface slip, load-displacement behavior

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental research on interfacial bonding performance of high‐strength steel pipe and surrounding concrete/grout for assembled composite columns. https://app.cochat.ai/papers/10.1002/suco.202201200
The paper
Zhu, Z., & Wang, J. (2023). Experimental research on interfacial bonding performance of high‐strength steel pipe and surrounding concrete/grout for assembled composite columns. Structural Concrete. https://doi.org/10.1002/suco.202201200

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.