Experimental research on interfacial bonding performance of high‐strength steel pipe and surrounding concrete/grout for assembled composite columns
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Abstract High‐strength steel pipe joints are proposed for assembled composite columns. The steel pipe extends into the upper and lower prefabricated columns and is anchored by poured concrete or grout to realize the connection of the prefabricated columns. Bonding performance of high‐strength steel pipe and surrounding concrete/grout is critical to the joint reliability. Steel pipe push‐out test was carried out, considering parameters of steel pipe section specification, bonding length, bonding material, and outer wall treatment of the steel pipe. Comparative analysis of measured load–displacement/slip curves and calculated bond strength were conducted. Bonding length of 600 mm could provide sufficient bond strength. Increasing bonding length could delay the slippage, but the bond strength decreased. High‐strength grout significantly increased the peak load size. The slenderness ratio and diameter–thickness ratio of the steel pipe had no obvious influence on the bonding performance. Steel pipe with D114*25 section obtained higher bonding strength with smaller ratio of bonding area to cross‐sectional area. Spiral ribs welded to the outer wall of the steel pipe could effectively improve the bonding strength and delay the interface slip. With easy construction and reliable performance, spiral ribs were recommended to be applied in prRactical projects.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Bond behavior in concrete-filled steel tubes
Tao, Z., Song, T.-Y., Uy, B., & Han, L.-H. (2016) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2015.12.030 · Cited by 296
Shariati, M., Mafipour, M. S., Mehrabi, P., Bahadori, A., Zandi, Y., Salih, M. N. A., Nguyen, H., Dou, J., Song, X., & Poi-Ngian, S. (2019) · Applied Sciences · doi:10.3390/app9245534 · Cited by 270
Structural and Economic Benefits of Precast/Prestressed Concrete Construction
Yee, A. A., & D., H. (2001) · PCI Journal · doi:10.15554/pcij.07012001.34.42 · Cited by 215
Social and Environmental Benefits of Precast Concrete Technology
Yee, A. A. (2001) · PCI Journal · doi:10.15554/pcij.05012001.14.19 · Cited by 209
Mohammadhassani, M., Nezamabadi–pour, H., Suhatril, M., & Shariati, M. (2014) · Smart Structures and Systems · doi:10.12989/sss.2014.14.5.785 · Cited by 157
Load-reversed push-out tests on rectangular CFST columns
Qu, X., Chen, Z., Nethercot, D. A., Gardner, L., & Theofanous, M. (2012) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2012.11.003 · Cited by 73
Wang, X., Liu, J., & Zhou, X. (2015) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2015.09.018 · Cited by 60
Shariati, M., Naghipour, M., Yousofizinsaz, G., et al. (2020) · Steel and Composite Structures · doi:10.12989/scs.2020.34.3.377 · Cited by 52
Structural performance of detachable precast composite column joints with mechanical metal plates
Nzabonimpa, J. D., & Hong, W. (2018) · Engineering Structures · doi:10.1016/j.engstruct.2018.01.038 · Cited by 48
Bond behavior of recycled aggregate concrete-filled steel tube after elevated temperatures
Chen, Z., Jia, H., & Li, S. (2022) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2022.126683 · Cited by 47
Naghipour, M., Yousofizinsaz, G., & Shariati, M. (2020) · Steel and Composite Structures · doi:10.12989/scs.2020.34.3.347 · Cited by 46
Bond stress-slip relationship in concrete-filled square stainless steel tubes
Dai, P., Yang, L., Wang, J., Lin, M., & Fan, J. (2022) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2022.127001 · Cited by 45
Self-citationAbendeh, R. M., Salman, D., & Allouzi, R. (2022) · Developments in the Built Environment · doi:10.1016/j.dibe.2022.100080 · Cited by 41
Investigation of pipe shear connectors using push out test
Nasrollahi, S., Maleki, S., Shariati, M., et al. (2018) · UTM Institutional Repository · doi:10.12989/scs.2018.27.5.537 · Cited by 39
Razavian, L., Naghipour, M., Shariati, M., et al. (2020) · STRUCTURAL ENGINEERING AND MECHANICS · doi:10.12989/sem.2020.74.1.145 · Cited by 37
Numerical Analysis of Composite Steel-Concrete Columns of Arbitrary Cross Section
Sousa, J. B. M., & Caldas, R. B. (2005) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2005)131:11(1721 · Cited by 33
Huang, Y., Zhao, P., Lu, Y., & Zhang, H. (2022) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2022.107263 · Cited by 25
Cha, K. J., Seo, J., Kim, S., et al. (2017) · Structural Concrete · doi:10.1002/suco.201700044 · Cited by 17
Zhang, Y., Wang, M., Yu, L., Guo, X., Liu, K., & Yang, H. (2021) · Structural Concrete · doi:10.1002/suco.202000564 · Cited by 14
Ke, X., Tang, Z., Shen, J., et al. (2022) · KSCE Journal of Civil Engineering · doi:10.1007/s12205-022-1998-9 · Cited by 9
Seismic performance of semi-precast composite columns with bolted end-plate connections to footing
Kim, C.-S., Jo, W.-B., Baek, S.-W., et al. (2022) · Engineering Structures · doi:10.1016/j.engstruct.2022.114174 · Cited by 6
Research works printed but not linked: 5
- Arabnejad KhanoukiMM Ramli SulongNH ShariatiM.Investigation of seismic behaviour of composite structures with concrete filled square steel tubular (CFSST) column by push‐over and time‐history analyses. In: Proceedings of the 4th international conference on steel composite structures July 21–23 Sydney Australia.2010.
- Commission of European Communities, 2004, Design of composite steel and concrete structures‐part1‐1: general rules and rules for buildings: EUROCODE 4 (EC4)
- British Standard Institute, 2005, Steel concrete and composite bridges‐part 5: code of practice for the design of composite bridges: BS 5400‐5
- Standards Australia, 2004, Bridge design part 6: steel and composite construction: AS 5100.6
- American Institute of Steel Construction, 2016, Specification for structural steel buildings: ANSI/AISC 360‐16
Cited by
Experimental research on seismic performance of hybrid connected prefabricated composite columns
Zhu, Z., Jin, P., Zheng, Y., et al. (2024) · Materials and Structures · doi:10.1617/s11527-024-02415-w · Cited by 6
“In this paper, hybrid connected prefabricated composite columns (HCPCC) are formed based on the previously proposed composite columns connected by steel pipe connectors [29].”
Self-citationTang, B., Zhao, F.-P., Jiang, Z., Zhang, B.-Z., & Cui, W. (2025) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2025.144301 · Cited by 2
Metadata
- Authors
- Zhu, Z., & Wang, J.
- Affiliations
- Nanjing Tech University (CN)
- Corresponding author
- Zhu, Zhangfeng
- Venue
- Structural Concrete
- Publisher
- Wiley
- Published
- 2023-08-28
- Volume
- 24
- Issue
- 6
- Pages
- 7103-7115
- ISSN
- 1464-4177 (ISSN-L)
- 1751-7648
- OpenAlex
- W4386253583
- Cited by
- 2
- References
- 21
- Citations by year
- 2025: 1 · 2024: 1
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Structural Concrete (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
- Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Materials Analysis
- Keywords
- high-strength steel pipe, steel-concrete bond, prefabricated columns, bond strength, bond lengths, spiral ribs, interface slip, load-displacement behavior
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.