Cited by 45Structural Load-Bearing AnalysisStructural Behavior of Reinforced ConcreteStructural Engineering and Materials Analysis

Bond stress-slip relationship in concrete-filled square stainless steel tubes

Open access
Dai, Peng, Yang, Lu, Wang, Jie, Lin, Manfang, Fan, Junwei·2022·Construction and Building Materials

Integrity signals

Registry

Crossref · 10.1016/j.conbuildmat.2022.127001

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

3 of 50 cited sources checked · 2 supported · 0 flagged · accuracy not yet measured

  • Premisecitation

    There is no consistent conclusion regarding the influence of concrete strength on the bond strength of concrete-filled steel tubes.

    “Regarding the influence of concrete strength on the bond strength, there is no consistent conclusion.”
    Quote in the paperNot a substantial claim1 of 4 sources checked
    • cites [4] 4. L.H. Xue, S.H. Cai, Bond strength at interface of concrete-filled steel tube columns (a), Build. Sci. 03 (1996) 22-28.

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [5] 5. L.H. Xue, S.H. Cai, Bond strength at interface of concrete-filled steel tube columns (b), Build. Sci. 04 (1996) 19-23.

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [14] 14. X. Chang, C.K. Huang, D.C. Jiang, Y.C. Song, Push-out test of pre-stressing concrete filled circular steel tube columns by means of expansive cement, Constr. Build. Mater. 23 (1) (2009) 491-497. source
    • cites [15] 15. X. S. Qu, Z. H. Chen, D. A. Nethercot, L. Gardner, and M. Theofanous, Push-out tests and bond strength of rectangular CFST columns, Steel Compos. Struct. 19 (1) (2015) 21-41. source
  • Premisecitation

    The length to width (diameter) ratios of concrete-filled steel tube columns used in engineering practice are usually greater than or equal to 3.

    “The length to width (diameter) ratios of CFST columns 115 used in engineering practice are usually greater than or equal to 3 [32]”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites [32] 32. P. Dai, L. Yang, J. Wang, Y. Zhou, Compressive strength of concrete-filled stainless steel tube stub columns, Eng. Struct. 205 (2020) 110106. source

      Section 2.1 (p. 5) says the study’s stub-column specimens were designed with L = 3D to avoid global instability and ensure local buckling. That supports the ratio for these specimens, but the paper does not establish that columns used in engineering practice usually have ratios of at least 3. (LLM, conf=0.86)

      Experimental — accuracy not yet measured
  • Findingown data

    For CFSSST specimens without rib stiffeners, slip occurred immediately as loading started.

    “It can be seen in Fig. 7 that the slip occurred immediately as the loading started, which can be attributed to the smooth surface of the stainless steel tube.”
    Quote in the paperNot a substantial claim
  • Findingown data

    Rib stiffeners can significantly improve the bond behavior in CFSSSTs.

    “It can be seen that the rib stiffeners can significantly improve the 242 bond behavior in CFSSSTs, and the PBL and saw-shaped rib stiffeners resulted in significantly higher 243 improvement in the bond behavior than the ordinary rib stiffeners.”
    Quote in the paperSubstantial claim
  • Findingreasoning

    When the bond stress reached τu, the bond stress began to decrease as the concrete filled the rough surface of the steel tube.

    “When the bond stress reached τu, the bond stress began to decrease as the concrete filled the rough surface of the steel tube.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. 15
  • May combine two claims. 34
  • The quote only partly states this claim. 2
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Some studies found that higher concrete strength may improve bond strength of concrete-filled steel tubes, whereas Yan et al. reached the opposite conclusion.

    “Xue and Cai [4,5], Chang et al. [14] and Qu et al. [15] found that the higher concrete strength may improve the bond strength, whereas Yan et al. [16] reached the opposite conclusion.”
    Quote in the paperNot a substantial claim1 of 4 sources checked
    • cites [4] 4. L.H. Xue, S.H. Cai, Bond strength at interface of concrete-filled steel tube columns (a), Build. Sci. 03 (1996) 22-28.

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [5] 5. L.H. Xue, S.H. Cai, Bond strength at interface of concrete-filled steel tube columns (b), Build. Sci. 04 (1996) 19-23.

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [14] 14. X. Chang, C.K. Huang, D.C. Jiang, Y.C. Song, Push-out test of pre-stressing concrete filled circular steel tube columns by means of expansive cement, Constr. Build. Mater. 23 (1) (2009) 491-497. source
    • cites [15] 15. X. S. Qu, Z. H. Chen, D. A. Nethercot, L. Gardner, and M. Theofanous, Push-out tests and bond strength of rectangular CFST columns, Steel Compos. Struct. 19 (1) (2015) 21-41. source
  • The quote only partly states this claim.

    Findingown data

    The slip displacement corresponding to τu in CFSSST specimens without rib stiffeners is only around 1 mm over a bond length of 900 mm.

    “For CFSSST specimens, the micro-interlocking force is the major component of the bond resistance before τu, as can be evidenced by Fig. 7 that the slip displacement corresponding to τu is only around 1 mm (compared to a bond length of 900 mm), which was unlikely to lead to large slide friction and be associated with the macro-interlocking force.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingnone given

    With increasing slip, the bond stress increased linearly with no obvious friction sound at this stage.

    “With the increase of the slip, the bond stress increased linearly with no obvious friction sound at this stage.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingreasoning

    After the first peak, a sudden huge sound occurred with the load dropping drastically without slipping.

    “This was followed by a sudden huge sound with the load dropped drastically without slipping.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingnone given

    In the later stage of loading, the load increased for a third time, accompanied by a large slip and intermittent slip sound.

    “In the later stage of loading, the load increased for the third time accompanied by a large slip and intermittent slip 190 sound.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The calculated and experimental bond stress-slip curves are basically consistent in the initial stage of loading due to the small confinement pressure of outer steel tubes to core concrete.

    “It can be 319 found that the two are basically consistent in the initial stage of loading due to the small confinement 320 pressure of outer steel tubes to core concrete.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: At the initial stage of loading, there is no significant confinement force from the steel tube to the concrete.
  • May combine two claims.

    Findingreasoning

    Increasing the concrete strength from 44 MPa to 77 MPa has a negative effect on τu for all four groups of specimens displayed, with a reduction of 24.4% on average.

    “Fig. 13(a) shows that increasing the concrete strength from 44 MPa to 77 MPa has a negative effect on τu for all the four groups of specimens displayed, with a reduction of 24.4% on average.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). The quote only partly states this claim.

    Findingnone given

    There was no obvious local buckling wave presented on the steel tube of all the specimens.

    “It is worth noting that there was no obvious local buckling wave presented on the 235 steel tube of all the specimens.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Based on the test results, an idealized bond stress-slip strain (τ-εS) curve was proposed, and good agreement between the test and the proposed model was achieved.

    “Based on the test results, an idealized bond stress-slip strain (τ-εS) curve was proposed, where good agreement between the test and the proposed model has been achieved.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Strain measurement in CFSSST-PBL and CFSSST-SS specimens showed that S32205 and 304 steel reached strains of 4900 and 5650 με, corresponding to stresses of 362 and 263 MPa, demonstrating that S32205 specimens provided higher confinement pressures to the concrete at the ultimate bond stress than the 304 specimens.

    “The strain measurement in the CFSSST-PBL and CFSSST -SS specimens also showed that the S32205 and 304 steel have reached strains of 4900 and 5650 με, corresponding to stresses of 362 and 263 MPa (Fig. 4), respectively, demonstrating that the S32205 specimens provided higher confinement pressures (macrointerlocking force) to the concrete at the ultimate bond stress than the 304 specimens.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    CFSSST-RS specimens experienced relatively large slip displacements at failure of 5-8 mm, allowing the steel and concrete to develop large deformations and hence a large macro-interlocking force.

    “On the other hand, the CFSSST-RS specimens experienced relatively large slip displacements at failure (5 -8 mm, as shown in Fig. 10), allowing the steel and concrete to develop large deformations hence a large macro-interlocking force.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The initial bond stress τi is taken as 0.025 MPa for 304 and 0.064 MPa for S32205 CFSSST columns according to the test results.

    “τi are taken as 0.025 and 0.064 MPa for 304 and S32205 CFSSST columns according to the test results.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    Bond strength in concrete-filled steel tubes can be affected by the diameter-wall thickness ratio D/t (width-thickness ratio B/t), concrete strength and concrete age.

    “To investigate the bond behavior in CFSTs, numerous previous studies [3][4][5][6][7][8][9][12][13][14][15][16][17] have carried out push-out tests, with the results showing that the bond strength can be affected by the diameter-wall thickness ratio D/t (the width-thickness ratio B/t) ratio of the steel tube, concrete strength and concrete age.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [3][4][5][6][7][8][9][12][13][14][15][16][17]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Premisecitation

    Chemical adhesion in concrete-filled steel tubes is relatively small, depends on the mechanical properties of the core concrete, and may fail under a small external load, allowing interface slip.

    “The magnitude of the chemical adhesion is relatively small and depends on the mechanical properties of the core concrete, indicating that the chemical adhesion bond may fail under a just small external load, and thus an interface slip in CFST may occur.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [3][4][5][6][7][8][9]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Increasing the D/t (B/t) ratio can lead to reductions in the ultimate bond stress of concrete-filled steel tubes.

    “Virdi and Dowling [3], Roeder et al. [12], Parsley et al. [13], Chang et al. [14], Tao et al. [6], Qu et al. [15], Guan et al. [7], Lyu and Han [9] and Yan et al. [16] studied the effect of D/t (B/t) ratio on the bond strength of CFSTs and concluded that increasing D/t (B/t) can lead to reductions in the ultimate bond stress.”
    Quote in the paperNot a substantial claim0 of 3 sources checked
    • cites [3] 3. K.S. Virdi, P.J. Dowling, Bond strength in concrete filled steel tubes, IABSE Proceedings, vol. 80, 1980, pp. 125-139, P-33. source
    • cites [12] 12. C.W. Roeder, B. Cameron, C.B. Brown, Composite action in concrete filled tubes, J. Struct. Eng. ASCE 125 (5) (1999) 477-484. source
    • cites [13] 13. M.A. Parsley, J.A. Yura, J.O. Jirsa, Push-out behavior of rectangular concrete-filled steel tubes, Publication of American Concrete Institute, 196-5, 2000, pp. 87-107. source
  • May combine two claims.

    Premisecitation

    Compared with ordinary rib stiffeners, saw-shaped and PBL rib stiffeners can reduce the amount of steel used and improve the bond strength and ductility of concrete-filled steel tube columns.

    “Compared with the ordinary rib stiffeners, the saw-shaped and PBL rib stiffeners can not only reduce the amount of steel used but also improve the bond strength and ductility of CFST columns [38,43].”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [38] 38. F. Alatshan, S. A. Osman, R. Hamid, F. Mashiri, Stiffened concrete-filled steel tubes: A systematic review, Thin-Walled Struct. 148 (2020) 106590. source
    • cites [43] 43. Z. Tao, L.H. Han, D.Y. Wang, Strength and ductility of stiffened thin-walled hollow steel structural stub columns filled with concrete, Thin-Walled Struct. 46 (2008) 1113-1128. source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The bond interface in concrete-filled stainless steel tubes can be broken in fire.

    “Song et al. [34] studied the bond strength in CFSSTs at elevated temperatures and showed that the bond interface can be broken in fire.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [34] 34. T.Y. Song, Z. Tao, L.H. Han, B. Uy, Bond behavior of concrete-filled steel tubes at elevated temperatures, J. Struct. Eng. 143 (11) (2017) 04017147. source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Grzeszykow et al. carried out analytical analyses of bond behavior at the steel-concrete interface through push-out tests and presented two analytical models of stress distribution.

    “Grzeszykow et al. [23] carried out analytical analyses of bond behavior at the interface between steel and concrete through push-out tests and presented two analytical models of stress distribution.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [23] 23. B. Grzeszykowski, M. Szadkowska, E. Szmigiera, Analysis of stress in steel and concrete in CFST push-out test samples, Civ. Environ. Eng. Rep. 26 (3) (2017) 145-159. source
  • May combine two claims.

    Interpretationown data

    Square hot-rolled tubes welded at the corner forming a right angle led to normal stress concentration at these areas when the load increased, thereby resulting in increased calculated bond stress.

    “The square hot-rolled tubes studied in the test program were welded at the corner, forming a right angle, which led to normal stress concentration at these areas when the load increased, thereby resulting in increased calculated bond stress.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    The macro-interlocking force is essentially friction related to the confinement pressure caused by the irregularity of diameter or width along the length of the tube, and it dominates the post-peak bond resistance.

    “The macrointerlocking force is essentially friction related to the confinement pressure caused by the irregularity of diameter or width along the length of the tube, which dominates the post-peak bond resistance, as shown in Fig. 9(b).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Premisecitation

    The bond strength of the steel-concrete interface in concrete-filled stainless steel tubes is less than that in concrete-filled steel tubes, caused by the smoother surface of the stainless steel tube.

    “However, the bond strength of the steel-concrete interface in concrete-filled stainless steel tubes (CFSSTs) is less than that in CFSTs, as caused by the smoother surface of the stainless steel tube [31].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [31] 31. L.H. Han, C.Y. Xu, Z. Tao, Performance of concrete filled stainless steel tubular (CFSST) columns and joints: Summary of recent research, J. Constr. Steel Res. 152 (2019) 117-131. source
  • May combine two claims.

    Premisereasoning

    Previous studies have only proved the lower bond strength of concrete-filled stainless steel tubes compared with concrete-filled steel tubes, whereas a design value has not been proposed.

    “It should be noted that these previous studies have only proved the lower bond strength of CFSSTs compared with CFSTs, whereas a design value has not been proposed.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Premisecitation

    Previous studies on the bond behavior of square CFSST specimens used seamless tubes with rounded corners, and no normal stress concentration was present.

    “Previous studies [8,34,36] on the bond behavior of square CFSST specimens used seamless tubes with rounded corners and no normal stress concentration was present.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [8] 8. Z. Tao, T.Y. Song, B. Uy, L.H. Han, Bond behavior in concrete-filled steel tubes, J. Constr. Steel Res. 120 (2016) 81-93. source
    • cites [34] 34. T.Y. Song, Z. Tao, L.H. Han, B. Uy, Bond behavior of concrete-filled steel tubes at elevated temperatures, J. Struct. Eng. 143 (11) (2017) 04017147. source
    • cites [36] 36. R. Feng, Y. Chen, K. He, J.G. Wei, B.C. Chen, X.T. Zhang, Push-out tests of concrete-filled stainless steel SHS tubes, J. Constr. Steel Res. 145 (2018) 58-69. source
  • Classified as probably not a substantial claim.

    Premisecitation

    Current design rules of concrete-filled steel tubes are inapplicable to the bond strength of concrete-filled stainless steel tubes.

    “Chen et al. [35] and Feng et al. [36] conducted push-out tests on CFSST specimens with circular and square sections, respectively, and concluded that the current design rules of CFSTs are inapplicable to the bond strength of CFSSTs.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [35] 35. Y. Chen, R. Feng, Y.B. Shao, X.T. Zhang, Bond-slip behaviour of concrete-filled stainless steel circular hollow section tubes, J. Constr. Steel Res. 130 (2017) 248-263. source
    • cites [36] 36. R. Feng, Y. Chen, K. He, J.G. Wei, B.C. Chen, X.T. Zhang, Push-out tests of concrete-filled stainless steel SHS tubes, J. Constr. Steel Res. 145 (2018) 58-69. source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The age of concrete significantly reduces the bond resistance of concrete-filled steel tubes.

    “Tao et al. [8] and Aly et al. [17] carried out push-out tests to investigate the effect of concrete age on the bond resistance, and found that the age of the concrete significantly reduces the bond resistance of CFSTs.”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [8] 8. Z. Tao, T.Y. Song, B. Uy, L.H. Han, Bond behavior in concrete-filled steel tubes, J. Constr. Steel Res. 120 (2016) 81-93. source
    • cites [17] 17. T. Aly, M. Elchalakani, P. Thayalan, I. Patnaikuni, Incremental collapse threshold for pushout resistance of circular concrete filled steel tubular columns, J. Constr. Steel Res. 66 (2010) 11-18. source
  • May combine two claims.

    Interpretationnone given

    Concrete-filled square stainless steel tube members present different confinement conditions from circular concrete-filled stainless steel tube members and thus result in different bond stress-slip relationships.

    “The present work focuses on concrete-filled square stainless steel tube (CFSSST) members, which present different confinement conditions to that in circular CFSST members and thus will result in different bond stress-slip relationships.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Chen et al. proposed a theoretical bond-slip model of concrete-filled checkered steel tube that accounted for the tensile strength of concrete and the height of the checkered part.

    “Chen et al. [22] proposed a theoretical bond-slip model of concrete-filled checkered steel tube, which took account of the tensile strength of concrete and height of the checkered part.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [22] 22. L. Chen, J. Dai, Q. Jin, L. Chen, X. Liu, Refining bond-slip constitutive relationship between checkered steel tube and concrete, Constr. Build. Mater. 79 (2015) 153-164. source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Adding an internal ring is a more effective method in enhancing bond strength in concrete-filled steel tube specimens compared to adding shear studs.

    “Song et al. [19] studied the bond behavior of CFSTs with shear studs or an internal ring and found that adding internal ring is a more effective method in enhancing the bond strength in CFST specimens compared to adding shear studs.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [19] 19. T.Y. Song, Z. Tao, B. Uy, L.H. Han, Bond strength in full-scale concrete-filled steel tubular columns, Proceedings of the 15th World Congress on Advances in Structural Engineering and Mechanics, Incheon, Korea, 2015.
  • May combine two claims.

    Interpretationreasoning

    Thicker (stockier) tubes associated with larger confinement pressure may provide higher friction force (macro-interlocking force) in the later stage of loading than thinner (more slender) tubes, thus leading to higher strain hardening responses.

    “Thicker (stockier) tubes associated 194 with larger confinement pressure may provide higher friction force (macro-interlocking force) in the 195 later stage of loading than thinner (more slender) tubes, thus leading to higher strain hardening responses.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Adding internal rings can be an effective method to enhance the bond strength of circular concrete-filled stainless steel tube members.

    “This previous study [37] has also shown that adding internal rings can be an effective method to enhance the bond strength of circular CFSST members.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [37] 37. P. Dai, L. Yang, J. Wang, J.W. Fan, M.F. Lin, Experimental study on the steel-concrete bond behaviour of circular concrete-filled stainless steel tubes, Thin-Walled Struct. 169 (2021) 108506. source
  • May combine two claims.

    Premisecitation

    The micro-interlocking force and macro-interlocking force can cause mechanical keying of the concrete core with the steel tube, and both can be viewed as friction.

    “It should be noted that the micro-interlocking force, as well as the macro-interlocking force, can cause mechanical keying of the concrete core with the steel tube, and therefore both can be viewed as friction [6,9].”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [6] 6. Z. Tao, L.H. Han, B. Uy, X. Chen, Post-fire bond between the steel tube and concrete in concrete- filled steel tubular columns, J. Constr. Steel Res. 67 (2011) 484-496. source
    • cites [9] 9. W. Q. Lyu, L. H. Han, Investigation on bond strength between recycled aggregate concrete (RAC) and steel tube in RAC-filled steel tubes, J. Constr. Steel Res. 155 (2019) 438-459. source
  • May combine two claims.

    Interpretationreasoning

    As slip developed further, accumulated large local stress in the corner regions caused crushing of the concrete at these locations and led to loss of the locally increased stress, hence resulting in a sudden drop in the calculated bond stress.

    “As the slip developed further, the accumulated large local stress in the corner regions caused the crushing of the concrete at these locations and led to the loss of the locally increased stress, hence resulting in a sudden drop in the calculated bond stress.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The bond strength in concrete-filled stainless steel tubes decreases remarkably with increasing cross-sectional dimension and concrete age.

    “Tao et al. [8] found that the bond strength in CFSSTs decreases remarkably with increasing cross-sectional dimension and concrete age in CFSST, and proposed methods to increase the bond strength.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [8] 8. Z. Tao, T.Y. Song, B. Uy, L.H. Han, Bond behavior in concrete-filled steel tubes, J. Constr. Steel Res. 120 (2016) 81-93. source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    In concrete-filled tubes, an exponential distribution of bond stress is expected prior to slip and a more uniform distribution occurs after slip.

    “Roeder et al. [12] studied the composite action in concrete-filled tubes, concluding that an exponential distribution of bond stress is expected prior to slip and a more uniform distribution occurs after the slip.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [12] 12. C.W. Roeder, B. Cameron, C.B. Brown, Composite action in concrete filled tubes, J. Struct. Eng. ASCE 125 (5) (1999) 477-484. source
  • May combine two claims.

    Interpretationreasoning

    The third increase in bond stress has not been observed in previous studies, which may be due to the different cross-sectional dimensions of the CFSSSTs considered.

    “The third increase in the bond stress has not been observed in previous studies [8,34,36], which 191 may be due to the different cross-sectional dimensions of the CFSSSTs considered.”
    Quote in the paperNot a substantial claim0 of 3 sources checked
    • cites [8] 8. Z. Tao, T.Y. Song, B. Uy, L.H. Han, Bond behavior in concrete-filled steel tubes, J. Constr. Steel Res. 120 (2016) 81-93. source
    • cites [34] 34. T.Y. Song, Z. Tao, L.H. Han, B. Uy, Bond behavior of concrete-filled steel tubes at elevated temperatures, J. Struct. Eng. 143 (11) (2017) 04017147. source
    • cites [36] 36. R. Feng, Y. Chen, K. He, J.G. Wei, B.C. Chen, X.T. Zhang, Push-out tests of concrete-filled stainless steel SHS tubes, J. Constr. Steel Res. 145 (2018) 58-69. source
  • May combine two claims.

    Premisecitation

    Rib stiffeners can enhance bond strength and improve the confinement effect of the flat regions of square tubes to concrete.

    “Rib stiffeners can not only enhance the bond strength but improve the confinement effect of the flat regions of square tubes to concrete [38].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [38] 38. F. Alatshan, S. A. Osman, R. Hamid, F. Mashiri, Stiffened concrete-filled steel tubes: A systematic review, Thin-Walled Struct. 148 (2020) 106590. source
  • May combine two claims.

    Interpretationreasoning

    The macro-interlocking force increased in the later stage of loading, which led to an increase of the bond resistance.

    “The macro-interlocking force here increased, which led to the increase of the bond resistance in the later stage of loading.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    The inconsistent effect of concrete strength on bond strength may be due to higher shrinkage from higher concrete strength reducing mechanical keying, while higher split tensile strength of the concrete core may increase resistance related to mechanical keying.

    “This may be due to the fact that the higher shrinkage caused by the higher concrete strength may reduce the mechanical keying between concrete and steel tube, whereas the higher split tensile strength of the concrete core may increase the resistance related to the mechanical keying [9].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [9] 9. W. Q. Lyu, L. H. Han, Investigation on bond strength between recycled aggregate concrete (RAC) and steel tube in RAC-filled steel tubes, J. Constr. Steel Res. 155 (2019) 438-459. source
  • May combine two claims.

    Interpretationreasoning

    Decreasing the B/t ratio can lead to improvement in τu for C40 specimens whereas this enhancement diminished in C80 specimens.

    “decreasing the B/t ratio can lead to improvement in τu for the C40 specimens whereas this enhancement diminished in the C80 specimens”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    The discrepancy after 1.2τb is because macro-interlocking force produced by the restraint of the steel tube on concrete dominates the bond stress and normal stress was not considered in the analysis.

    “This 322 phenomenon is due to macro-interlocking force produced by the restraint of steel tube on concrete 323 dominates the bond stress, however, the normal stress was not considered in the analysis.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    S32205 steels with higher strengths than 304 steels at the same strain can provide a larger confinement pressure, thereby reaching a higher macro-interlocking force and thus higher bond stress in the later stage of loading.

    “The S32205 steels with higher strengths than 304 steels at the same strain (Fig. 4) can provide a larger confinement pressure, thereby reaching a higher macro-interlocking force and thus higher bond stress in the later stage of loading.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    S32205 specimens with better corrosion resistance and a smoother surface provided a smaller micro-interlocking force than S304 specimens, hence resulting in smaller τu at failure for CFSSSTs without rib stiffeners.

    “Therefore, the S32205 specimens with a better corrosion resistance [45,46] and a smoother surface provided a smaller micro-interlocking force than the S304 specimens, hence resulting in smaller τu at failure.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [45] 45. G.P. Shu, Y.Y. Gu, Y.Q. Zhang, X. Jin, B.F. Zheng, Q.L. Jiang, Experimental study of cold-drawn duplex stainless steel circular tubes under axial compression, Thin-Walled Struct. 138 (2019) 95- 104. source
    • cites [46] 46. S.K. Azad, D.X. Li, B. Uy, Axial slenderness limits for duplex and lean duplex stainless steel- concrete composite columns, J. Constr. Steel Res. 172 (2020) 106175. source
  • May combine two claims.

    Interpretationreasoning

    Decreasing the B/t ratio of the steel tube can provide greater confinement pressure to the concrete, leading to a higher micro-interlocking force and hence a higher τu for C40 specimens.

    “While decreasing the B/t ratio of the steel tube can provide a greater confinement pressure to the concrete, leading to a higher micro-interlocking force hence a higher τu as observed for the C40 specimens”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationnone given

    In branch OA, there is no slip due to chemical adhesion.

    “In branch OA, there is no slip due to the chemical adhesion”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationown data

    The sectional width-thickness ratio (B/t), concrete strength (fcu), and stainless steel type have obvious influence on the bond behavior of CFSSST columns.

    “As above, sectional width-thickness ratio (B/t), concrete strength (fcu) and stainless steel types (grade 304 and S32205) have obvious influence on the bond behavior of CFSSST columns.”
    Quote in the paperSubstantial claim
45 of 45
  • The paper relies on this without support.

    In beam-column joints and braced frames of complex building structures, the bond strength between the outer steel tube and concrete is insufficient to transfer shear load.

    “In beam-column joints and braced frames of complex building structures, the bond strength between outer steel tube and concrete is insufficient to transfer shear load, therefore, the shear connectors need to be adopted to realize a full composite action.”
  • The authors state this as an assumption.

    PBL rib stiffeners enhance shear transfer between the concrete and steel stiffener by forming concrete dowels passing through the holes on the plated steel stiffener.

    “The PBL stiffeners are expected to enhance the shear transfer between the concrete and steel stiffener by forming concrete dowels passing through the holes on the plated steel stiffener.”
  • The authors state this as an assumption.

    Saw-shaped rib stiffeners have a comparable effect to PBL stiffeners.

    “The saw-shaped rib stiffeners were fabricated by opening rectangular holes on one side of the steel plate, considered to have a comparable effect as PBL stiffener.”
  • The authors state this as an assumption.

    At the initial stage of loading, there is no significant confinement force from the steel tube to the concrete.

    “Since at the initial stage of loading there was no significant confinement force from the steel tube to the 307 concrete”
  • The authors state this as an assumption.

    The interface between the steel tube and concrete can be simplified as pure vertical force equilibrium at the initial stage.

    “Therefore, the interface between the two is simplified as pure vertical force equilibrium, as follows:”
  • The authors state this as an assumption.

    Branch BC of the idealized τ-εS curve can be considered as a quadratic parabola with the derivative of bond stress at point C equal to zero.

    “Therefore, branch BC is considered as a quadratic parabola, and the derivative of the stress bond at point C (εSb, τb) is equal to zero.”
  • The authors state this as an assumption.

    The second derivative of the bond stress at point C is equal to zero, and the derivative of the bond stress at point D is equal to zero.

    “The second derivative of the bond stress at point C is equal to zero, and the derivative of the bond stress at point D is equal to zero.”
7 of 7

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Concrete strength is stated as both 77 and 76 MPa

    Minor

    The discussion says the higher measured concrete strength is 77 MPa, while Table 1 lists 76 MPa for the C80 specimens.

1 of 1

Cites

Flagged first, then by citations

4 of the 46 references couldn’t be matched to a known paper.

Research works printed but not linked: 3

  1. Xue, 1996, Bond strength at interface of concrete-filled steel tube columns (a), Build. Sci., 03, 22
  2. Xue, 1996, Bond strength at interface of concrete-filled steel tube columns (b), Build. Sci., 04, 19
  3. Z. Tao, B. Uy, L.H. Han, Bond strength between the steel tube and concrete in concrete-filled steel columns, Proceedings of the Inaugural Annual Conference of the Institute for Infrastructure Engineering, Sydney, Australia 2012, pp. 22–23.

Cited by

Sorted by citations

Authors
Dai, P., Yang, L., Wang, J., Lin, M., & Fan, J.
Affiliations
  • Beijing University of Technology (CN)
  • University of Bath (GB)
Corresponding author
Yang, Lu
Venue
Construction and Building Materials
Publisher
Elsevier BV
Published
2022-04
Volume
326
Pages
127001
ISSN
0950-0618 (ISSN-L)
OpenAlex
W4214911398
Cited by
45
References
46
Citations by year
2026: 11 · 2025: 13 · 2024: 10 · 2023: 8 · 2022: 3
FWCI
3.79
Type
journal article
Language
en
Open access
Locations
  • Construction and Building Materials (publishedVersion)
  • Pure (University of Bath) (acceptedVersion, cc-by-nc-nd)
Funders
  • Foundation for Innovative Research Groups of the National Natural Science Foundation of China
  • National Natural Science Foundation of China (51922001, 51421005)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
  • Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Materials Analysis
Keywords
bond-slip behavior, push-out test, rib stiffeners, width-to-thickness ratio, concrete compressive strength, austenitic stainless steel, duplex stainless steel, bond mechanism, bond stress-slip curve, corrosion resistance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-11.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-11.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review