The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Optimal sensor placement for structural health monitoring based on multiple optimization strategies
Abstract
SUMMARY: Careful selection and placement of sensors are the critical issue in the construction and implementation of an effective structural health monitoring system. A hybrid method termed the optimal sensor placement strategy (OSPS) based on multiple optimization methods is proposed in this paper. The initial sensor placement is firstly obtained by the QR factorization. Then, using the minimization of the off‐diagonal elements in the modal assurance criterion matrix as a measure of the utility of a sensor configuration, the quantity of the sensors is determined by the forward and backward sequential sensor placement algorithm together. Finally, the locations of the sensor are determined by the dual‐structure coding‐based generalized genetic algorithm (GGA). Taking the scientific calculation software matlab (MathWorks, Natick, MA, USA) as a platform, an OSPS toolbox, which is working as a black box, is developed based on the command‐line compiling and graphical user interface‐aided graphical interface design. The characteristic and operation method of the toolbox are introduced in detail, and the scheme selection of the OSP is carried out on the world's tallest TV tower (Guangzhou New TV Tower) based on the developed toolbox. The results indicate that the proposed method is effective and the software package has a friendly interface, plenty of functions, good expansibility and is easy to operate, which can be easily applied in practical engineering. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holland, J. H. (1992) · The MIT Press eBooks · doi:10.7551/mitpress/1090.001.0001 · Cited by 47,002
Reduction of stiffness and mass matrices
GUYAN, R. J. (1965) · AIAA Journal · doi:10.2514/3.2874 · Cited by 2,642
Fibre Bragg gratings in structural health monitoring—Present status and applications
Majumder, M., Gangopadhyay, T. K., Chakraborty, A. K., Dasgupta, K., & Bhattacharya, D. K. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.04.008 · Cited by 973
Sensor placement for on-orbit modal identification and correlation of large space structures
Kammer, D. C. (1991) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20635 · Cited by 935
Recent applications of fiber optic sensors to health monitoring in civil engineering
Li, H.-N., Li, D.-S., & Song, G.-B. (2004) · Engineering Structures · doi:10.1016/j.engstruct.2004.05.018 · Cited by 897
Self-citationProceedings of the 15th International Modal Analysis Conference
Vol., P. S. (1997) · Cited by 683
Optimal sensor placement methodology for parametric identification of structural systems
Papadimitriou, C. (2004) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2003.10.063 · Cited by 465
Ni, Y. Q., Xia, Y., Liao, W. Y., & Ko, J. M. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.303 · Cited by 397
On the optimal sensor placement techniques for a bridge structure
Meo, M., & Zumpano, G. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2005.03.015 · Cited by 389
Wenzel, H. (2009) · Wiley eBooks · doi:10.1002/9780470740170 · Cited by 311
Cited by
Abdulkarem, M., Samsudin, K., Rokhani, F. Z., & A Rasid, M. F. (2020) · Structural Health Monitoring · doi:10.1177/1475921719854528 · Cited by 424
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
The Sensable City: A Survey on the Deployment and Management for Smart City Monitoring
Du, R., Santi, P., Xiao, M., Vasilakos, A. V., & Fischione, C. (2019) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2881008 · Cited by 289
State-of-the-art in structural health monitoring of large and complex civil infrastructures
Li, H.-N., Ren, L., Jia, Z.-G., Yi, T.-H., & Li, D.-S. (2016) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-015-0108-9 · Cited by 274
Self-citationRecent research and applications of GPS-based monitoring technology for high-rise structures
Yi, T.-H., Li, H.-N., & Gu, M. (2013) · Structural Control and Health Monitoring · doi:10.1002/stc.1501 · Cited by 258
Self-citationComputational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Li, J., Hao, H., & Chen, Z. (2017) · Journal of Aerospace Engineering · doi:10.1061/(asce)as.1943-5525.0000550 · Cited by 44
An Improved Genetic Algorithm for Optimal Sensor Placement in Space Structures Damage Detection
Beygzadeh, S., Salajegheh, E., Torkzadeh, P., Salajegheh, J., & Naseralavi, S. S. (2014) · International Journal of Space Structures · doi:10.1260/0266-3511.29.3.121 · Cited by 25
Metadata
- Authors
- Yi, T., Li, H., & Gu, M.
- Venue
- The Structural Design of Tall and Special Buildings
- Publisher
- Wiley
- Published
- 2011-06-17
- Volume
- 20
- Issue
- 7
- Pages
- 881-900
- ISSN
- 1541-7794 (ISSN-L)
- 1541-7808
- OpenAlex
- W1525659763
- Cited by
- 288
- References
- 14
- FWCI
- 73.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.