The DOI matches its Crossref record.
Gelatin microspheres crosslinked with genipin for local delivery of growth factors
Open accessAbstract
A main challenge in tissue engineering and regenerative medicine is achieving local and efficient growth factor release to guide cell function. Gelatin is a denatured form of collagen that cells can bind to and degrade through enzymatic action. In this study, gelatin microspheres were used to release bone morphogenetic protein 2 (BMP2). Spherical microparticles with diameters in the range of 2-6 µm were created by an emulsification process and were stabilized by crosslinking with the small molecule genipin. The degree of crosslinking was varied by controlling the incubation time in genipin solution. Loading rate studies, using soy bean trypsin inhibitor as a model protein, showed rapid protein uptake over the first 24 h, followed by a levelling off and then a further increase after approximately 3 days, as the microspheres swelled. Growth factor release studies using microspheres crosslinked to 20%, 50% and 80% of saturation and then loaded with BMP2 showed that higher degrees of crosslinking resulted in higher loading efficiency and slower protein release. After 24 h, the concentration profiles produced by all microsphere formulations were steady and approximately equal. Microspheres incubated with adult human mesenchymal stem cells accumulated preferentially on the cell surface, and degraded over time in culture. BMP2-loaded microspheres caused a three- to eight-fold increase in expression of the bone sialoprotein gene after 14 days in culture, with more crosslinked beads producing a greater effect. These results demonstrate that genipin-crosslinked gelatin microspheres can be used to deliver growth factors locally to cells in order to direct their function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Frohbergh, M. E., Katsman, A., Botta, G. P., Lazarovici, P., Schauer, C. L., Wegst, U. G. K., & Lelkes, P. I. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.09.009 · Cited by 411
Role of angiogenesis in bone repair
Saran, U., Gemini Piperni, S., & Chatterjee, S. (2014) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2014.07.006 · Cited by 362
Vascularized Bone Tissue Engineering: Approaches for Potential Improvement
Nguyen, L. H., Annabi, N., Nikkhah, M., Bae, H., Binan, L., Park, S., Kang, Y., Yang, Y., & Khademhosseini, A. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2012.0012 · Cited by 313
Novel Biomedical Applications of Crosslinked Collagen
Gu, L., Shan, T., Ma, Y.-X., Tay, F. R., & Niu, L. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.10.007 · Cited by 305
Guziewicz, N., Best, A., Perez-Ramirez, B., & Kaplan, D. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.12.023 · Cited by 260
Annamalai, R. T., Turner, P. A., Carson, W. F., Levi, B., Kunkel, S., & Stegemann, J. P. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.040 · Cited by 155
Self-citation
Metadata
- Authors
- Solorio, L., Zwolinski, C., Lund, A. W., Farrell, M. J., & Stegemann, J. P.
- Venue
- Journal of Tissue Engineering and Regenerative Medicine
- Publisher
- Hindawi Limited
- Published
- 2010-08-19
- Volume
- 4
- Issue
- 7
- Pages
- 514-523
- ISSN
- 1932-6254 (ISSN-L)
- OpenAlex
- W2141033585
- Cited by
- 169
- References
- 0
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.