CoChat

Three‐dimensional (3D) and 4D color Doppler fetal echocardiography using spatio‐temporal image correlation (STIC)

Open access
Chaoui, R., Hoffmann, J., Heling, K. S. · 2004 · Ultrasound in Obstetrics & Gynecology
Cited by 229

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objective: Color Doppler echocardiography is used to visualize three transverse planes: the four‐chamber, five‐chamber, and three vessels and trachea views. Color Doppler spatio‐temporal image correlation (STIC) is a new three‐dimensional (3D) technique allowing the acquisition of a volume of data from the fetal heart that is displayed as a cineloop of a single cardiac cycle. The aim of the study was to examine the potential of color Doppler STIC to evaluate normal and abnormal fetal hearts. Methods: This prospective study included 35 normal fetuses and 27 fetuses with congenital heart defects (CHD) examined between 18 and 35 weeks of gestation. Volume acquisition was achieved by initiating the image capture sequence from the transverse four‐chamber view. Volumes were stored for later offline evaluation using a personal computer‐based workstation in a multiplanar mode and as spatial volume rendering. Results: Successful acquisition was possible in all 62 cases. The three planes could be demonstrated in 31/35 healthy fetuses and in 24/27 fetuses with CHD. Spatial volume rendering was attempted in 18 fetuses with CHD. In the four normal fetuses with inadequate visualization using color Doppler STIC, the region of interest was perpendicular to the ultrasound beam. In two fetuses with CHD inadequate visualization was related to an enlarged heart in late gestation, in which the entire cardiac volume could not be acquired. The third case was an 18‐week fetus with complex CHD and transposed great vessels in which artifacts were related to confluent color signals as a result of low resolution in the reconstructed plane. Conclusions: STIC in combination with color Doppler ultrasound is a promising new tool for multiplanar and 3D/4D rendering of the fetal heart. Limitations may be found later in gestation in fetuses with large hearts and early in gestation as a result of low discrimination of signals. In addition, insonation perpendicular to the structure of interest does not image color Doppler signals and should be avoided during acquisition. Copyright © 2004 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.1075

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 229

Metadata

Authors
Chaoui, R., Hoffmann, J., & Heling, K. S.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2004-05-06
Volume
23
Issue
6
Pages
535-545
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2086187166
Cited by
229
References
1
FWCI
16.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three‐dimensional (3D) and 4D color Doppler fetal echocardiography using spatio‐temporal image correlation (STIC). https://app.cochat.ai/papers/10.1002/uog.1075
The paper
Chaoui, R., Hoffmann, J., & Heling, K. S. (2004). Three‐dimensional (3D) and 4D color Doppler fetal echocardiography using spatio‐temporal image correlation (STIC). Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.1075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.