CoChat

Reproducibility of assessment of severity of pelvic endometriosis using transvaginal ultrasound

Holland, T. K., Hoo, W. L., Mavrelos, D., Saridogan, E., Cutner, A., Jurkovic, D. · 2013 · Ultrasound in Obstetrics & Gynecology
Cited by 36

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objective: To examine the reproducibility of assessment of severity of pelvic endometriosis by transvaginal sonography (TVS). Methods: This was a prospective observational study conducted from August 2006 to July 2009 in two academic departments of obstetrics and gynecology. Women with clinically suspected or proven pelvic endometriosis were invited to join the study. All patients included underwent TVS performed by two observers and a laparoscopic assessment of pelvic endometriosis. The ultrasound observers were blinded to each other's results. The reproducibility of TVS was examined by evaluation of interobserver agreement for the American Society of Reproductive Medicine (ASRM) score by Bland–Altman analysis and the stage and the diagnosis of deeply infiltrating endometriosis (DIE) by calculation of kappa coefficients. Agreement between the findings on TVS for each observer and those on laparoscopy was also evaluated. Results: Thirty‐four patients were recruited to the study, and TVS was performed by two ultrasound observers. Of these patients, one did not undergo laparoscopy and was therefore excluded from the final analysis. No endometriosis was found in 12 (36.4%) patients. One patient (3%) had minimal disease, one (3%) had mild disease, five (15.2%) had moderate disease and 14 (42.4%) had severe disease. Interobserver agreement was very good for disease classification on TVS (Cohen's kappa, 0.931). Agreement between TVS and laparoscopy findings was also very good (Cohen's kappa, 0.955 and 0.966 for the two examiners). For ASRM score on TVS, the interobserver 95% limits of agreement were –16.6 to 12.7, with a mean difference of –1.9 (95% CI, –4.35 to 0.71). Conclusion: TVS is a reproducible method for assessment of the severity of pelvic endometriosis and shows good agreement with findings on laparoscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.11216

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 36

Metadata

Authors
Holland, T. K., Hoo, W. L., Mavrelos, D., Saridogan, E., Cutner, A., & Jurkovic, D.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2013-01-31
Volume
41
Issue
2
Pages
210-215
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1781662602
Cited by
36
References
4
FWCI
4.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of assessment of severity of pelvic endometriosis using transvaginal ultrasound. https://app.cochat.ai/papers/10.1002/uog.11216
The paper
Holland, T. K., Hoo, W. L., Mavrelos, D., Saridogan, E., Cutner, A., & Jurkovic, D. (2013). Reproducibility of assessment of severity of pelvic endometriosis using transvaginal ultrasound. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.11216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.