The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reproducibility of three‐dimensional ultrasound diagnosis of congenital uterine anomalies
Open accessAbstract
Objective: To examine the reproducibility of the diagnosis of congenital uterine anomalies and the repeatability of measurements of uterine cavity dimensions using three‐dimensional (3D) ultrasound. Methods: The reproducibility of diagnosis of congenital uterine anomalies was examined by re‐slicing stored 3D ultrasound volumes. Each data set was evaluated by two independent observers. Assessment of uterine morphology was performed in a standardized plane, with the interstitial portions of the Fallopian tubes used as reference points. Additionally, in 35 cases of congenital uterine anomalies the width of the uterine cavity (W), fundal distortion (F) and the length of unaffected uterine cavity (C) were measured. Intraobserver and interobserver variabilities were evaluated by each observer performing all three measurements twice. Results: Eighty‐three 3D ultrasound volumes were examined. Both operators classified 27 uteri as normal, 33 as arcuate, 19 as subseptate and three as unicornuate. A single case of uterine anomaly was described as arcuate uterus by one operator and subseptate by another (kappa 0.97). The intraobserver variability for each of the three measurements (W, F and C) was satisfactory with limits of agreement ranging from ±1.43 to ±2.51 mm. The examination of the interobserver variability showed no significant differences between the two observers (F = 0.484, P > 0.05). Conclusion: 3D ultrasound is a reproducible method for the diagnosis of congenital uterine anomalies and for the measurement of uterine cavity dimensions. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Chan, Y. Y., Jayaprakasan, K., Zamora, J., Thornton, J. G., Raine-Fenning, N., & Coomarasamy, A. (2011) · Human Reproduction Update · doi:10.1093/humupd/dmr028 · Cited by 758
Saravelos, S. H., Cocksedge, K. A., & Li, T.-C. (2008) · Human Reproduction Update · doi:10.1093/humupd/dmn018 · Cited by 683
Evidence-based guidelines for the investigation and medical treatment of recurrent miscarriage
Jauniaux, E. (2006) · Human Reproduction · doi:10.1093/humrep/del150 · Cited by 520
Ludwin, A., Martins, W. P., Nastri, C. O., Ludwin, I., Coelho Neto, M. A., Leitão, V. M., Acién, M., Alcazar, J. L., Benacerraf, B., Condous, G., et al. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.18923 · Cited by 139
Graupera, B., Pascual, M. A., Hereter, L., Browne, J. L., Úbeda, B., Rodríguez, I., & Pedrero, C. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14825 · Cited by 109
Metadata
- Authors
- Salim, R., Woelfer, B., Backos, M., Regan, L., & Jurkovic, D.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2003-06
- Volume
- 21
- Issue
- 6
- Pages
- 578-582
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2075811345
- Cited by
- 228
- References
- 1
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of three‐dimensional ultrasound diagnosis of congenital uterine anomalies. https://app.cochat.ai/papers/10.1002/uog.127
- The paper
- Salim, R., Woelfer, B., Backos, M., Regan, L., & Jurkovic, D. (2003). Reproducibility of three‐dimensional ultrasound diagnosis of congenital uterine anomalies. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.127
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.