Fusion imaging for evaluation of deep infiltrating endometriosis: feasibility and preliminary results
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objective: Magnetic resonance imaging (MRI) and ultrasound scanning complement each other in screening for and diagnosis of endometriosis. Fusion imaging, also known as real‐time virtual sonography, is a new technique that uses magnetic navigation and computer software for the synchronized display of real‐time ultrasound and multiplanar reconstructed MR images. Our aim was to evaluate the feasibility and ability of fusion imaging to assess the main anatomical sites of deep infiltrating endometriosis (DIE) in patients with suspected active endometriosis. Methods: This prospective study was conducted over a 1‐month period in patients referred to a trained radiologist for an ultrasound‐based evaluation for endometriosis. Patients with a prior pelvic MRI examination within the past year were offered fusion imaging, in addition to the standard evaluation. All MRI examinations were performed on a 1.5‐T MRI machine equipped with a body phased‐array coil. The MRI protocol included acquisition of at least two fast spin‐echo T2‐weighted orthogonal planes. The Digital Imaging Communications in Medicine dataset acquired at the time of the MRI examination was loaded into the fusion system and displayed together with the ultrasound image on the same monitor. The sets of images were then synchronized manually using one plane and one anatomical reference point. The ability of this combined image to identify and assess the main anatomical sites of pelvic endometriosis (uterosacral ligaments, posterior vaginal fornix, rectum, ureters and bladder) was evaluated and compared with that of standard B‐mode ultrasound and MRI. Results: Over the study period, 100 patients were referred for ultrasound examination because of endometriosis. Among them were 20 patients (median age, 35 (range, 27–49) years) who had undergone MRI examination within the past year, with a median (range) time interval between MRI and ultrasound examination of 171 (1–350) days. All 20 patients consented to undergo additional evaluation by fusion imaging. However, in three (15%) cases, fusion imaging was not technically possible because of changes since the initial MRI examination resulting from either interval surgery (n = 2; 10%) or pregnancy (n = 1; 5%). Data acquisition, matching and fusion imaging were performed in under 10 min in each of the other 17 cases. The overall ability of each technique to identify and assess the main anatomical landmarks of endometriosis was as follows: uterosacral ligaments: ultrasound, 88% (30/34); MRI, 100% (34/34); fusion imaging, 100% (34/34); posterior vaginal fornix: ultrasound, 88% (30/34); MRI, 100% (34/34); fusion imaging, 100% (34/34); rectum: ultrasound, 100% (17/17); MRI, 82.3% (14/17); fusion imaging, 100% (17/17); ureters: ultrasound, 0%; MRI, 100% (34/34); fusion imaging, 100% (34/34); and bladder: ultrasound, 100%; MRI, 100%; fusion imaging, 100%. Conclusion: Fusion imaging is feasible for the assessment of endometriotic lesions. Because it combines information from both ultrasound and MRI techniques, fusion imaging allows better identification of the main anatomical sites of DIE and has the potential to improve the performance of ultrasound and MRI examination. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giudice, L. C. (2010) · New England Journal of Medicine · doi:10.1056/nejmcp1000274 · Cited by 1,924
Bulun, S. E. (2009) · New England Journal of Medicine · doi:10.1056/nejmra0804690 · Cited by 1,772
Koninckx, P. R., Meuleman, C., Demeyere, S., Lesaffre, E., & Cornillie, F. J. (1991) · Fertility and Sterility · doi:10.1016/s0015-0282(16)54244-7 · Cited by 849
Deep Pelvic Endometriosis: MR Imaging for Diagnosis and Prediction of Extension of Disease
Bazot, M., Darai, E., Hourani, R., Thomassin, I., Cortez, A., Uzan, S., & Buy, J.-N. (2004) · Radiology · doi:10.1148/radiol.2322030762 · Cited by 580
Bazot, M., Lafont, C., Rouzier, R., Roseau, G., Thomassin-Naggara, I., & Daraï, E. (2009) · Fertility and Sterility · doi:10.1016/j.fertnstert.2008.09.005 · Cited by 434
Hudelist, G., English, J., Thomas, A. E., Tinelli, A., Singer, C. F., & Keckstein, J. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8858 · Cited by 270
Cited by
Imaging modalities for the non-invasive diagnosis of endometriosis
Nisenblat, V., Bossuyt, P. M., Farquhar, C., Johnson, N., & Hull, M. L. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009591.pub2 · Cited by 538
Bazot, M., & Daraï, E. (2017) · Fertility and Sterility · doi:10.1016/j.fertnstert.2017.10.026 · Cited by 255
Santulli, P., Bourdon, M., Presse, M., Gayet, V., Marcellin, L., Prunet, C., de Ziegler, D., & Chapron, C. (2016) · Fertility and Sterility · doi:10.1016/j.fertnstert.2015.12.006 · Cited by 82
Bourdon, M., Raad, J., Dahan, Y., Marcellin, L., Maignien, C., Even, M., Pocate-Cheriet, K., Lamau, M. C., Santulli, P., & Chapron, C. (2018) · PLOS ONE · doi:10.1371/journal.pone.0202399 · Cited by 42
Self-citation
Metadata
- Authors
- Millischer, A. ‐., Salomon, L. J., Santulli, P., Borghese, B., Dousset, B., & Chapron, C.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2015-07
- Volume
- 46
- Issue
- 1
- Pages
- 109-117
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2158191999
- Cited by
- 56
- References
- 6
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.