The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
How to measure cervical length
Abstract
How to… Practical advice on imaging-based techniques and investigations with accompanying slides and videoclips online Cervical-length measurement using transvaginal sonography (TVS) is an essential part of assessing the risk of preterm delivery. At mid-gestation, it provides a useful method with which to predict the likelihood of subsequent preterm birth in asymptomatic women. In women who present with threatened spontaneous preterm labor, TVS measurement of cervical length can help to distinguish between 'true' and 'false' spontaneous preterm labor. Additionally, there is some evidence that measurement of the cervix at the 11+0 to 13+6-week scan can help to establish the risk of preterm birth1, 2. To et al.3 reported on cervical-length measurement between 22 and 24 weeks' gestation in 39 000 women with a singleton pregnancy. The cervical length was found to be distributed normally, with a mean length of 36 mm. In about 1% of the women, the length was 15 mm or less. This cut-off is generally used to define the high-risk group in interventional studies4. In most studies focusing on asymptomatic twin pregnancies at 20 to 24 weeks, a cut-off of 25 mm is applied5. Celik et al.6 used cervical-length measurements obtained between 20 and 24 weeks' gestation, along with maternal history, in more than 58 000 women to create computed risk models for preterm delivery. They compared patients who delivered before 28 weeks, between 28 and 30 weeks, between 31 and 33 weeks, and between 34 and 36 weeks' gestation. For a 10% false-positive rate, the sensitivities were 81%, 59%, 53% and 29%, respectively. In a Health Technology Assessment report, Honest et al.7 summarized the results of five studies that used cervical-length measurements between 20 and 24 weeks, with cut-offs of 20–30 mm, to predict preterm birth before 34 weeks' gestation. The resultant positive likelihood ratios ranged from 2.3 for 30 mm to 7.6 for 20 mm. It has been shown that only 15% of symptomatic patients presenting with preterm contractions will actually deliver within the next 7 days8. Cervical length can be used to distinguish between 'true' and 'false' labor. Sotiriadis et al.9 summarized six studies, including about 1800 women, that assessed the risk for preterm delivery within 1 week, based on cervical length at the time of admission. With a cut-off of 15 mm, the sensitivity was about 60% for a false-positive rate of about 10%. The respective positive and negative likelihood ratios were 5.7 and 0.5. With cut-offs of 20 and 25 mm, the sensitivities increased to 75% and 80%, but at the expense of false-positive rates of 20% and 30%, respectively. Recent work10 has shown that cervical length at 11–13 weeks' gestation, in combination with maternal history, can detect about half of the pregnancies that result in preterm delivery before 34 weeks, for a false-positive rate of 10%. However, the difference between the median cervical length of the normal group and that of the preterm-birth group was only 5 mm (32.5 mm vs 27.5 mm)10, which raises doubts as to whether this technique can be used for general screening. There are essentially four methods that can be used to evaluate the uterine cervix: digital examination, transabdominal ultrasound, transperineal ultrasound (TPS) and TVS. It is the digital examination that provides the most comprehensive evaluation of the cervix, assessing dilatation, position, consistency and length. However, this examination suffers from being subjective. It is limited especially in its ability to establish accurately the cervical length. It also cannot detect reproducibly any changes at the internal cervical os and the upper portion of the cervical canal. Ultrasound, with its ability to penetrate the cervical tissue and display its anatomy, makes an ideal modality with which to address both of these issues. Both TVS and TPS are performed with the patient in a dorsal lithotomy position. In order for the measurement to be accurate and reproducible, the following factors need to be taken into account (Figure 1 and Videoclip S1): The patient having a full bladder can increase artificially the cervical length. To et al.11 showed that the mean difference between cervical length measured when the patient's bladder is empty and that measured when the bladder is full is about 4 mm. In addition, a full bladder can obscure the presence of cervical funneling by compressing the two halves of the funnel together (Figure 2). The cervix should be measured along its longitudinal axis, which may be different from the patient's longitudinal axis. The cervical canal, in most cases, is a fairly thin line. It may have a thin layer of hypoechoic contents. This is true especially in the third trimester. In all likelihood, it represents accumulation of mucus, and needs to be differentiated from a thin cervical funnel. This is best done by delineating the course of the fetal membranes: if they are not prolapsing into the cervical canal and are loc
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Greco, E., Gupta, R., Syngelaki, A., Poon, L. C. Y., & Nicolaides, K. H. (2012) · Fetal Diagnosis and Therapy · doi:10.1159/000335686 · Cited by 126
Cited by
ISUOG Practice Guidelines (updated): performance of the routine mid‐trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C. M., Chalouhi, G. E., Da Silva Costa, F., Hernandez‐Andrade, E., Malinger, G., Munoz, H., Paladini, D., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24888 · Cited by 436
McIntosh, J., Feltovich, H., Berghella, V., & Manuck, T. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.04.027 · Cited by 265
Burgos-Artizzu, X. P., Coronado-Gutiérrez, D., Valenzuela-Alcaraz, B., Bonet-Carne, E., Eixarch, E., Crispi, F., & Gratacós, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-67076-5 · Cited by 240
Metadata
- Authors
- Kagan, K. O., & Sonek, J.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2015-01-29
- Volume
- 45
- Issue
- 3
- Pages
- 358-362
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2081549505
- Cited by
- 169
- References
- 1
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How to measure cervical length. https://app.cochat.ai/papers/10.1002/uog.14742
- The paper
- Kagan, K. O., & Sonek, J. (2015). How to measure cervical length. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.14742
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.