Prediction of small‐for‐gestational‐age neonates: screening by fetal biometry at 30–34 weeks
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: To investigate the value of fetal biometry at 30–34 weeks' gestation in the prediction of delivery of small‐for‐gestational‐age (SGA) neonates, in the absence of pre‐eclampsia (PE). Methods: This was a screening study in 30 849 singleton pregnancies at 30–34 weeks' gestation, comprising 1727 that delivered SGA neonates with a birth weight < 5 th percentile and 29 122 cases unaffected by SGA, PE or gestational hypertension. Multivariable logistic regression analysis was used to determine if screening by a combination of maternal factors and Z‐scores of fetal head circumference (HC), abdominal circumference (AC) and femur length (FL) or estimated fetal weight (EFW) had a significant contribution to the prediction of SGA neonates. Results: Combined screening by maternal characteristics and obstetric history, with Z‐scores of EFW at 30–34 weeks, predicted 79%, 87% and 92% of the SGA neonates that delivered < 5 weeks following assessment, with a birth weight < 10 th, < 5 th and < 3 rd percentiles, respectively, at a 10% false‐positive rate. The respective detection rates for the prediction of SGA neonates delivering ≥ 5 weeks from the time of assessment were 53%, 58% and 61%. The performance of screening by a combination of Z‐scores of fetal HC, AC and FL was similar to that achieved by the EFW Z‐score alone. Conclusion: Combined testing by maternal characteristics and fetal biometry at 30–34 weeks could identify a high proportion of pregnancies that will deliver SGA neonates. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In utero analysis of fetal growth: a sonographic weight standard
Hadlock, F. P., Harrist, R. B., & Martinez-Poyer, J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887021 · Cited by 1,281
Prediction of small-for-gestation neonates from biophysical and biochemical markers at 11-13 weeks
Karagiannis, G., Akolekar, R., Sarquis, R., Wright, D., & Nicolaides, K. H. (2011) · Fetal Diagnosis and Therapy · doi:10.1159/000321694 · Cited by 195
Self-citationDavid, C., Tagliavini, G., Pilu, G., Rudenholz, A., & Bovicelli, L. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70347-2 · Cited by 62
Cited by
Diagnosis and surveillance of late-onset fetal growth restriction
Figueras, F., Caradeux, J., Crispi, F., Eixarch, E., Peguero, A., & Gratacos, E. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.003 · Cited by 300
Madden, J. V., Flatley, C. J., & Kumar, S. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.02.008 · Cited by 133
Caradeux, J., Martinez-Portilla, R. J., Peguero, A., Sotiriadis, A., & Figueras, F. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.043 · Cited by 122
Poon, L. C., Lesmes, C., Gallo, D. M., Akolekar, R., & Nicolaides, K. H. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14904 · Cited by 68
Self-citationPapastefanou, I., Nowacka, U., Syngelaki, A., Dragoi, V., Karamanis, G., Wright, D., & Nicolaides, K. H. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23593 · Cited by 27
Self-citation
Metadata
- Authors
- Bakalis, S., Silva, M., Akolekar, R., Poon, L. C., & Nicolaides, K. H.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2015-03-10
- Volume
- 45
- Issue
- 5
- Pages
- 551-558
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2916252756
- Cited by
- 73
- References
- 3
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.