The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Accuracy of transvaginal ultrasound for diagnosis of deep endometriosis in uterosacral ligaments, rectovaginal septum, vagina and bladder: systematic review and meta‐analysis
Open accessAbstract
Objective: To review the diagnostic accuracy of transvaginal ultrasound (TVS) in the preoperative detection of endometriosis in the uterosacral ligaments (USL), rectovaginal septum (RVS), vagina and bladder in patients with clinical suspicion of deep infiltrating endometriosis (DIE). Methods: An extensive search was performed in MEDLINE (PubMed) and EMBASE for studies published between January 1989 and December 2014. Studies were considered eligible if they reported on the use of TVS for the preoperative detection of endometriosis in the USL, RVS, vagina and bladder in women with clinical suspicion of DIE using the surgical data as a reference standard. Study quality was assessed using the PRISMA guidelines and QUADAS‐2 tool. Results: Of the 801 citations identified, 11 studies (n = 1583) were considered eligible and were included in the meta‐analysis. For detection of endometriosis in the USL, the overall pooled sensitivity and specificity of TVS were 53% (95%CI, 35–70%) and 93% (95%CI, 83–97%), respectively. The pretest probability of USL endometriosis was 54%, which increased to 90% when suspicion of endometriosis was present after TVS examination. For detection of endometriosis in the RVS, the overall pooled sensitivity and specificity were 49% (95%CI, 36–62%) and 98% (95%CI, 95–99%), respectively. The pretest probability of RVS endometriosis was 24%, which increased to 89% when suspicion of endometriosis was present after TVS examination. For detection of vaginal endometriosis, the overall pooled sensitivity and specificity were 58% (95%CI, 40–74%) and 96% (95%CI, 87–99%), respectively. The pretest probability of vaginal endometriosis was 17%, which increased to 76% when suspicion of endometriosis was present after TVS assessment. Substantial heterogeneity was found for sensitivity and specificity for all these locations. For detection of bladder endometriosis, the overall pooled sensitivity and specificity were 62% (95%CI, 40–80%) and 100% (95%CI, 97–100%), respectively. Moderate heterogeneity was found for sensitivity and specificity for bladder endometriosis. The pretest probability of bladder endometriosis was 5%, which increased to 92% when suspicion of endometriosis was present after TVS assessment. Conclusion: Overall diagnostic performance of TVS for detecting DIE in uterosacral ligaments, rectovaginal septum, vagina and bladder is fair with high specificity. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
Koninckx, P. R., Meuleman, C., Demeyere, S., Lesaffre, E., & Cornillie, F. J. (1991) · Fertility and Sterility · doi:10.1016/s0015-0282(16)54244-7 · Cited by 849
Bazot, M., Lafont, C., Rouzier, R., Roseau, G., Thomassin-Naggara, I., & Daraï, E. (2009) · Fertility and Sterility · doi:10.1016/j.fertnstert.2008.09.005 · Cited by 434
Cited by
Guerriero, S., Condous, G., van den Bosch, T., Valentin, L., Leone, F. P. G., Van Schoubroeck, D., Exacoustos, C., Installé, A. J. F., Martins, W. P., Abrao, M. S., et al. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15955 · Cited by 900
Self-citationEuropean society of urogenital radiology (ESUR) guidelines: MR imaging of pelvic endometriosis
Bazot, M., Bharwani, N., Huchon, C., Kinkel, K., Cunha, T. M., Guerra, A., Manganaro, L., Buñesch, L., Kido, A., Togashi, K., et al. (2017) · European Radiology · doi:10.1007/s00330-016-4673-z · Cited by 346
Endometriosis: advances and controversies in classification, pathogenesis, diagnosis, and treatment
Rolla, E. (2019) · F1000Research · doi:10.12688/f1000research.14817.1 · Cited by 326
Bazot, M., & Daraï, E. (2017) · Fertility and Sterility · doi:10.1016/j.fertnstert.2017.10.026 · Cited by 255
Leone Roberti Maggiore, U., Ferrero, S., Candiani, M., Somigliana, E., Viganò, P., & Vercellini, P. (2017) · European Urology · doi:10.1016/j.eururo.2016.12.015 · Cited by 187
Metadata
- Authors
- Guerriero, S., Ajossa, S., Minguez, J. A., Jurado, M., Mais, V., Melis, G. B., & Alcazar, J. L.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2015-11
- Volume
- 46
- Issue
- 5
- Pages
- 534-545
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2131149447
- Cited by
- 237
- References
- 4
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of transvaginal ultrasound for diagnosis of deep endometriosis in uterosacral ligaments, rectovaginal septum, vagina and bladder: systematic review and meta‐analysis. https://app.cochat.ai/papers/10.1002/uog.15667
- The paper
- Guerriero, S., Ajossa, S., Minguez, J. A., Jurado, M., Mais, V., Melis, G. B., & Alcazar, J. L. (2015). Accuracy of transvaginal ultrasound for diagnosis of deep endometriosis in uterosacral ligaments, rectovaginal septum, vagina and bladder: systematic review and meta‐analysis. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.15667
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.