Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 360

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

International estimated fetal weight standards of the INTERGROWTH‐21st Project

Open access
Stirnemann, J., Villar, J., Salomon, L. J., Ohuma, E., Ruyan, P., Altman, D. G., Nosten, F., Craik, R., Munim, S., Cheikh Ismail, L., Barros, F. C., Lambert, A., Norris, S., Carvalho, M., Jaffer, Y. A., Noble, J. A., Bertino, E., Gravett, M. G., Purwar, M., Victora, C. G., Uauy, R., Bhutta, Z., Kennedy, S., Papageorghiou, A. T., for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21)·2017·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: Estimated fetal weight (EFW) and fetal biometry are complementary measures used to screen for fetal growth disturbances. Our aim was to provide international EFW standards to complement the INTERGROWTH‐21 st Fetal Growth Standards that are available for use worldwide. Methods: Women with an accurate gestational‐age assessment, who were enrolled in the prospective, international, multicenter, population‐based Fetal Growth Longitudinal Study (FGLS) and INTERBIO‐21 st Fetal Study (FS), two components of the INTERGROWTH‐21 st Project, had ultrasound scans every 5 weeks from 9–14 weeks' until 40 weeks' gestation. At each visit, measurements of fetal head circumference (HC), biparietal diameter, occipitofrontal diameter, abdominal circumference (AC) and femur length (FL) were obtained blindly by dedicated research sonographers using standardized methods and identical ultrasound machines. Birth weight was measured within 12 h of delivery by dedicated research anthropometrists using standardized methods and identical electronic scales. Live babies without any congenital abnormality, who were born within 14 days of the last ultrasound scan, were selected for inclusion. As most births occurred at around 40 weeks' gestation, we constructed a bootstrap model selection and estimation procedure based on resampling of the complete dataset under an approximately uniform distribution of birth weight, thus enriching the sample size at extremes of fetal sizes, to achieve consistent estimates across the full range of fetal weight. We constructed reference centiles using second‐degree fractional polynomial models. Results: Of the overall population, 2404 babies were born within 14 days of the last ultrasound scan. Mean time between the last scan and birth was 7.7 (range, 0–14) days and was uniformly distributed. Birth weight was best estimated as a function of AC and HC (without FL) as log(EFW) = 5.084820 − 54.06633 × (AC/100)3 − 95.80076 × (AC/100)3 × log(AC/100) + 3.136370 × (HC/100), where EFW is in g and AC and HC are in cm. All other measures, gestational age, symphysis–fundus height, amniotic fluid indices and interactions between biometric measures and gestational age, were not retained in the selection process because they did not improve the prediction of EFW. Applying the formula to FGLS biometric data (n = 4231) enabled gestational age‐specific EFW tables to be constructed. At term, the EFW centiles matched those of the INTERGROWTH‐21 st Newborn Size Standards but, at < 37 weeks' gestation, the EFW centiles were, as expected, higher than those of babies born preterm. Comparing EFW cross‐sectional values with the INTERGROWTH‐21 st Preterm Postnatal Growth Standards confirmed that preterm postnatal growth is a different biological process from intrauterine growth. Conclusions: We provide an assessment of EFW, as an adjunct to routine ultrasound biometry, from 22 to 40 weeks' gestation. However, we strongly encourage clinicians to evaluate fetal growth using separate biometric measures such as HC and AC, as well as EFW, to avoid the minimalist approach of focusing on a single value. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.17347

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Cited by

See all 360

Metadata

Authors
Stirnemann, J., Villar, J., Salomon, L. J., Ohuma, E., Ruyan, P., Altman, D. G., Nosten, F., Craik, R., Munim, S., Cheikh Ismail, L., Barros, F. C., Lambert, A., Norris, S., Carvalho, M., Jaffer, Y. A., Noble, J. A., Bertino, E., Gravett, M. G., Purwar, M., Victora, C. G., Uauy, R., Bhutta, Z., Kennedy, S., Papageorghiou, A. T., & for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21)
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2017-03-05
Volume
49
Issue
4
Pages
478-486
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2548866056
Cited by
360
References
59
FWCI
33.81
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: International estimated fetal weight standards of the INTERGROWTH‐21st Project. https://app.cochat.ai/papers/10.1002/uog.17347
The paper
Stirnemann, J., Villar, J., Salomon, L. J., Ohuma, E., Ruyan, P., Altman, D. G., Nosten, F., Craik, R., Munim, S., Cheikh Ismail, L., Barros, F. C., Lambert, A., Norris, S., Carvalho, M., Jaffer, Y. A., Noble, J. A., Bertino, E., Gravett, M. G., Purwar, M., . . . for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21). (2017). International estimated fetal weight standards of the INTERGROWTH‐21st Project. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.17347

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.