The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
International estimated fetal weight standards of the INTERGROWTH‐21st Project
Open accessAbstract
Objective: Estimated fetal weight (EFW) and fetal biometry are complementary measures used to screen for fetal growth disturbances. Our aim was to provide international EFW standards to complement the INTERGROWTH‐21 st Fetal Growth Standards that are available for use worldwide. Methods: Women with an accurate gestational‐age assessment, who were enrolled in the prospective, international, multicenter, population‐based Fetal Growth Longitudinal Study (FGLS) and INTERBIO‐21 st Fetal Study (FS), two components of the INTERGROWTH‐21 st Project, had ultrasound scans every 5 weeks from 9–14 weeks' until 40 weeks' gestation. At each visit, measurements of fetal head circumference (HC), biparietal diameter, occipitofrontal diameter, abdominal circumference (AC) and femur length (FL) were obtained blindly by dedicated research sonographers using standardized methods and identical ultrasound machines. Birth weight was measured within 12 h of delivery by dedicated research anthropometrists using standardized methods and identical electronic scales. Live babies without any congenital abnormality, who were born within 14 days of the last ultrasound scan, were selected for inclusion. As most births occurred at around 40 weeks' gestation, we constructed a bootstrap model selection and estimation procedure based on resampling of the complete dataset under an approximately uniform distribution of birth weight, thus enriching the sample size at extremes of fetal sizes, to achieve consistent estimates across the full range of fetal weight. We constructed reference centiles using second‐degree fractional polynomial models. Results: Of the overall population, 2404 babies were born within 14 days of the last ultrasound scan. Mean time between the last scan and birth was 7.7 (range, 0–14) days and was uniformly distributed. Birth weight was best estimated as a function of AC and HC (without FL) as log(EFW) = 5.084820 − 54.06633 × (AC/100)3 − 95.80076 × (AC/100)3 × log(AC/100) + 3.136370 × (HC/100), where EFW is in g and AC and HC are in cm. All other measures, gestational age, symphysis–fundus height, amniotic fluid indices and interactions between biometric measures and gestational age, were not retained in the selection process because they did not improve the prediction of EFW. Applying the formula to FGLS biometric data (n = 4231) enabled gestational age‐specific EFW tables to be constructed. At term, the EFW centiles matched those of the INTERGROWTH‐21 st Newborn Size Standards but, at < 37 weeks' gestation, the EFW centiles were, as expected, higher than those of babies born preterm. Comparing EFW cross‐sectional values with the INTERGROWTH‐21 st Preterm Postnatal Growth Standards confirmed that preterm postnatal growth is a different biological process from intrauterine growth. Conclusions: We provide an assessment of EFW, as an adjunct to routine ultrasound biometry, from 22 to 40 weeks' gestation. However, we strongly encourage clinicians to evaluate fetal growth using separate biometric measures such as HC and AC, as well as EFW, to avoid the minimalist approach of focusing on a single value. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
Flexible smoothing with B-splines and penalties
Eilers, P. H. C., & Marx, B. D. (1996) · Statistical Science · doi:10.1214/ss/1038425655 · Cited by 3,666
Generalized additive models for location, scale and shape.
Rigby, R. A., & Stasinopoulos, D. M. (2005) · Journal of the Royal Statistical Society Series C: Applied Statistics · doi:10.1111/j.1467-9876.2005.00510.x · Cited by 3,228
Smoothing reference centile curves: The lms method and penalized likelihood
Cole, T. J., & Green, P. J. (1992) · Statistics in Medicine · doi:10.1002/sim.4780111005 · Cited by 2,781
Villar, J., Ismail, L. C., Victora, C. G., Ohuma, E. O., Bertino, E., Altman, D. G., Lambert, A., Papageorghiou, A. T., Carvalho, M., Jaffer, Y. A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60932-6 · Cited by 2,281
Self-citationRegression Using Fractional Polynomials of Continuous Covariates: Parsimonious Parametric Modelling
Royston, P., & Altman, D. G. (1994) · Applied Statistics · doi:10.2307/2986270 · Cited by 1,798
Self-citationGeneralized Additive Models for Location Scale and Shape (GAMLSS) in R
Stasinopoulos, D. M., & Rigby, R. A. (2007) · Journal of Statistical Software · doi:10.18637/jss.v023.i07 · Cited by 1,560
A CRITICAL EVALUATION OF SONAR “CROWN‐RUMP LENGTH” MEASUREMENTS
Robinson, H. P., & Fleming, J. E. E. (1975) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1975.tb00710.x · Cited by 1,413
Nonparametric Regression and Generalized Linear Models: A Roughness Penalty Approach.
Best, D. J., Green, P. J., & Silverman, B. W. (1994) · Biometrics · doi:10.2307/2533467 · Cited by 1,177
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006
Self-citationThe who Multicentre Growth Reference Study: Planning, Study Design, and Methodology
de Onis, M., Garza, C., Victora, C. G., Onyango, A. W., Frongillo, E. A., & Martines, J. (2004) · Food and Nutrition Bulletin · doi:10.1177/15648265040251s104 · Cited by 961
Self-citationde Onis, M., & Habicht, J. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.4.650 · Cited by 961
Papageorghiou, A. T., Ohuma, E. O., Altman, D. G., Todros, T., Ismail, L. C., Lambert, A., Jaffer, Y. A., Bertino, E., Gravett, M. G., Purwar, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61490-2 · Cited by 870
Self-citationWorm plot: a simple diagnostic device for modelling growth reference curves
Buuren, S. V., & Fredriks, M. (2001) · Statistics in Medicine · doi:10.1002/sim.746 · Cited by 570
A systematic review of the ultrasound estimation of fetal weight
Dudley, N. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1751 · Cited by 537
de Onis, M., Onyango, A. W., Van den Broeck, J., Chumlea, W. C., & Martorell, R. (2004) · Food and Nutrition Bulletin · doi:10.1177/15648265040251s105 · Cited by 529
Nonparametric Regression and Generalized Linear Models: A roughness penalty approach
Green, P. J., & Silverman, B. W. (1993) · Chapman & Hall/CRC eBooks · doi:10.1201/b15710 · Cited by 510
Borghi, E., de Onis, M., Garza, C., Van den Broeck, J., Frongillo, E. A., Grummer-Strawn, L., Van Buuren, S., Pan, H., Molinari, L., Martorell, R., et al. (2006) · Statistics in Medicine · doi:10.1002/sim.2227 · Cited by 450
Fitting Smoothed Centile Curves to Reference Data
Cole, T. J. (1988) · Journal of the Royal Statistical Society. Series A (Statistics in Society) · doi:10.2307/2982992 · Cited by 413
Rigby, R. A., & Stasinopoulos, D. M. (2004) · Statistics in Medicine · doi:10.1002/sim.1861 · Cited by 374
Villar, J., Papageorghiou, A. T., Pang, R., Ohuma, E. O., Ismail, L. C., Barros, F. C., Lambert, A., Carvalho, M., Jaffer, Y. A., Bertino, E., et al. (2014) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(14)70121-4 · Cited by 370
Self-citationVillar, J., Giuliani, F., Bhutta, Z. A., Bertino, E., Ohuma, E. O., Ismail, L. C., Barros, F. C., Altman, D. G., Victora, C., Noble, J. A., et al. (2015) · The Lancet Global Health · doi:10.1016/s2214-109x(15)00163-1 · Cited by 357
Self-citationThe Use of Resampling Methods to Simplify Regression Models in Medical Statistics
Sauerbrei, W. (1999) · Journal of the Royal Statistical Society Series C: Applied Statistics · doi:10.1111/1467-9876.00155 · Cited by 310
Constructing time‐specific reference ranges
Royston, P. (1991) · Statistics in Medicine · doi:10.1002/sim.4780100502 · Cited by 310
The objectives, design and implementation of the INTERGROWTH‐21st Project
Villar, J., Altman, D., Purwar, M., Noble, J., Knight, H., Ruyan, P., Cheikh Ismail, L., Barros, F., Lambert, A., Papageorghiou, A., et al. (2013) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12047 · Cited by 287
Self-citationRationale for Developing a New International Growth Reference
Garza, C., & de Onis, M. (2004) · Food and Nutrition Bulletin · doi:10.1177/15648265040251s102 · Cited by 222
Using the Box-Cox t distribution in GAMLSS to model skewness and kurtosis
Rigby, R. A., & Stasinopoulos, D. M. (2006) · Statistical Modelling · doi:10.1191/1471082x06st122oa · Cited by 212
Pignotti, M. S., & Donzelli, G. (2008) · Pediatrics · doi:10.1542/peds.2007-0513 · Cited by 204
Statistics Notes: Bootstrap resampling methods
Bland, J. M., & Altman, D. G. (2015) · BMJ · doi:10.1136/bmj.h2622 · Cited by 199
Self-citationIntra‐ and interobserver variability in fetal ultrasound measurements
Sarris, I., Ioannou, C., Chamberlain, P., Ohuma, E., Roseman, F., Hoch, L., Altman, D. G., Papageorghiou, A. T., & for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21) (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10082 · Cited by 195
Self-citationDesign and analysis of studies to derive charts of fetal size
Altman, D. G., & Chitty, L. S. (1993) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1993.03060378.x · Cited by 163
Self-citationConde‐Agudelo, A., Papageorghiou, A. T., Kennedy, S. H., & Villar, J. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12172 · Cited by 152
Self-citationSystematic review of methodology used in ultrasound studies aimed at creating charts of fetal size
Ioannou, C., Talbot, K., Ohuma, E. O., Sarris, I., Villar, J., Conde‐Agudelo, A., & Papageorghiou, A. T. (2012) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2012.03451.x · Cited by 151
Self-citationSalomon, L. J., Bernard, J. P., Duyme, M., Doris, B., Mas, N., & Ville, Y. G. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2665 · Cited by 146
Self-citationKurmanavicius, J., Burkhardt, T., Wisser, J., & Huch, R. (2004) · Journal of Perinatal Medicine · doi:10.1515/jpm.2004.028 · Cited by 128
Using the LMS method to measure skewness in the NCHS and Dutch National height standards
Cole, T. J. (1989) · Annals of Human Biology · doi:10.1080/03014468900000532 · Cited by 117
Design and analysis of longitudinal studies of fetal size
Royston, P. J., & Altman, D. G. (1995) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1995.06050307.x · Cited by 113
Self-citationFractional polynomial model selection procedures: investigation of type i error rate
Ambler, G., & Royston, P. J. (2001) · Journal of Statistical Computation and Simulation · doi:10.1080/00949650108812083 · Cited by 111
A Comparison of Statistical Methods for Age-related Reference Intervals
Wright, E. M., & Royston, P. J. (1997) · Journal of the Royal Statistical Society Series A (Statistics in Society) · doi:10.1111/1467-985x.00045 · Cited by 109
Sarris, I., Ioannou, C., Dighe, M., Mitidieri, A. M. D. S., Oberto, M., Qingqing, W., Shah, J., Sohoni, S., Zidjali, W. A., Hoch, L., et al. (2011) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.8997 · Cited by 84
Self-citationUltrasound methodology used to construct the fetal growth standards in the INTERGROWTH ‐21st Project
Papageorghiou, A. T., Sarris, I., Ioannou, C., Todros, T., de Carvalho, M. H. B., Pilu, G., & Salomon, L. J. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12313 · Cited by 80
Self-citationSarris, I., Ioannou, C., Ohuma, E. O., Altman, D. G., Hoch, L., Cosgrove, C., Fathima, S., Salomon, L. J., & Papageorghiou, A. T. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12315 · Cited by 79
Self-citationIsmail, L. C., Knight, H., Ohuma, E. O., Hoch, L., & Chumlea, W. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12127 · Cited by 65
Self-citationAltman, D. G., & Ohuma, E. O. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12031 · Cited by 61
Self-citationIsmail, L. C., Knight, H., Bhutta, Z. A., & Chumlea, W. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12125 · Cited by 61
Self-citationBellera, C. A., & Hanley, J. A. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.09.004 · Cited by 60
Standardisation of crown-rump length measurement
Ioannou, C., Sarris, I., Hoch, L., Salomon, L., Papageorghiou, A., & for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21) (2013) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12056 · Cited by 59
Self-citationBakalis, S., Peeva, G., Gonzalez, R., Poon, L. C., & Nicolaides, K. H. (2015) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.14863 · Cited by 54
Monitoring human growth and development: a continuum from the womb to the classroom
Villar, J., Papageorghiou, A. T., Pang, R., Salomon, L. J., Langer, A., Victora, C. G., Purwar, M., Chumlea, C., Qingqing, W., Scherjon, S. A., et al. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2015.07.002 · Cited by 52
Self-citationImage-scoring system for crown-rump length measurement
Wanyonyi, S. Z., Napolitano, R., Ohuma, E. O., Salomon, L. J., & Papageorghiou, A. T. (2014) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13376 · Cited by 51
Self-citationCohen, J. M., Hutcheon, J. A., Kramer, M. S., Joseph, K. S., Abenhaim, H. A., & Platt, R. W. (2009) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7506 · Cited by 48
Lesmes, C., Gallo, D. M., González, R., Poon, L. C., & Nicolaides, K. H. (2015) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.14899 · Cited by 46
Prediction of estimated fetal weight in extremely low birth weight neonates (500-1000 g).
Medchill, M. T., Peterson, C. M., Kreinick, C. J., et al. (1991) · PubMed · Cited by 31
Proctor, L., Rushworth, V., Shah, P. S., Keunen, J., Windrim, R. C., Ryan, G., & Kingdom, J. C. (2010) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7605 · Cited by 31
Managing data for the international, multicentre INTERGROWTH ‐21st Project
Ohuma, E. O., Hoch, L., Cosgrove, C., Knight, H., Ismail, L. C., Juodvirsiene, L., Papageorghiou, A. T., Al-Jabri, H., Domingues, M. R., Gilli, P., et al. (2013) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12080 · Cited by 29
Self-citationWade, A. M., & Kurmanavicius, J. (2008) · Biostatistics · doi:10.1093/biostatistics/kxn022 · Cited by 12
Approaches for Constructing Age-Related Reference Intervals and Centile Charts for Fetal Size
Hynek, M. (2010) · European Journal for Biomedical Informatics · doi:10.24105/ejbi.2010.06.1.9 · Cited by 12
Stirnemann, J., Benoist, G., Salomon, L. J., Bernard, J. P., & Ville, Y. G. (2013) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13288 · Cited by 8
Self-citation
Cited by
ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth
Salomon, L. J., Alfirevic, Z., Da Silva Costa, F., Deter, R. L., Figueras, F., Ghi, T., Glanc, P., Khalil, A., Lee, W., Napolitano, R., et al. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20272 · Cited by 704
Self-citationMelamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Fetal Medicine Foundation fetal and neonatal population weight charts
Nicolaides, K. H., Wright, D., Syngelaki, A., Wright, A., & Akolekar, R. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.19073 · Cited by 356
Papageorghiou, A. T., Kennedy, S. H., Salomon, L. J., Altman, D. G., Ohuma, E. O., Stones, W., Gravett, M. G., Barros, F. C., Victora, C., Purwar, M., et al. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.01.011 · Cited by 299
Self-citationKiserud, T., Benachi, A., Hecher, K., Perez, R. G., Carvalho, J., Piaggio, G., & Platt, L. D. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.010 · Cited by 228
Metadata
- Authors
- Stirnemann, J., Villar, J., Salomon, L. J., Ohuma, E., Ruyan, P., Altman, D. G., Nosten, F., Craik, R., Munim, S., Cheikh Ismail, L., Barros, F. C., Lambert, A., Norris, S., Carvalho, M., Jaffer, Y. A., Noble, J. A., Bertino, E., Gravett, M. G., Purwar, M., Victora, C. G., Uauy, R., Bhutta, Z., Kennedy, S., Papageorghiou, A. T., & for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21)
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2017-03-05
- Volume
- 49
- Issue
- 4
- Pages
- 478-486
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2548866056
- Cited by
- 360
- References
- 59
- FWCI
- 33.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.