The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Prenatal diagnosis of congenital heart disease using four-dimensional spatio-temporal image correlation (STIC) telemedicine via an Internet link: a pilot study
Open accessAbstract
OBJECTIVE: To assess whether the spatio-temporal image correlation (STIC) acquisition technique can be taught to a general obstetrician by e-mail; whether STIC volume datasets can be transmitted over the Internet; and whether STIC volume datasets analyzed offline at a remote setting can be used to confirm or exclude major cardiac defects (TELE-STIC). METHODS: This was a prospective study involving 50 pregnant women with gestational ages ranging between 20 and 36 weeks. These patients were selected by two general obstetricians (operators) working in geographically remote areas of Chile. Although both obstetricians were users of equipment capable of four-dimensional (4D) ultrasound with STIC, they lacked skill in the performance of fetal cardiac examination. A dedicated web disk was created to upload the acquired volume datasets using an Internet broadband connection. Offline analysis was performed by a single investigator experienced in fetal echocardiography (the administrator). RESULTS: A telemedicine link via the Internet was possible in all cases. Seventy-seven volume datasets were sent to the web server. A complete cardiac examination according to set criteria was achieved by the administrator in 86% of the cases scanned by one operator and 95% of the cases scanned by the other operator. Three patients had cardiac defects confirmed postnatally, two fetuses had extracardiac anomalies and one fetus had a suspected cardiac defect unconfirmed by second-opinion TELE-STIC. There were two isolated major congenital heart defects. Both patients were given advice by e-mail and teleconference using a web camera about the likely outcome and benefits of scheduling in utero transport to a tertiary care center. CONCLUSIONS: STIC volumes can be obtained by operators inexperienced in fetal echocardiography, transmitted via the Internet, and their analysis enables recognition of most of the structures and views necessary to assess fetal cardiac anatomy. The preliminary use of TELE-STIC allowed us to demonstrate that some intracardiac anomalies can be ruled out and others confirmed, allowing perinatal management to be tailored accordingly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These changes include earlier treatment and appropriate escalation of care to tertiary centers (37).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [37]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Tele-ultrasound has demonstrated success in producing high quality, diagnostically significant images which alter management, decrease time to treatment, and provide more cost-effective care, especially when coupled with supporting data such as electrocardiogram, chest radiography, laboratory results, and clinical history (29, 30, 33, 35, 37, 48).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“Tele-ultrasound has demonstrated success in producing high quality, diagnostically significant images which alter management, decrease time to treatment, and provide more cost-effective care, especially when coupled with supporting data such as electrocardiogram, chest radiography, laboratory results, and clinical history (29, 30, 33, 35, 37, 48).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“Image acquisition can be taught from a distance via the internet and a telemedicine platform is reliably able to transmit high quality images (29, 34, 37, 38).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“In an attempt to overcome such challenges, ultrasound training programs have taught non-experts either to independently perform obstetric ultrasounds to screen for high-risk pregnancies (52–55) or to utilize tele-ultrasound (29, 34, 37, 38).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [37]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Tele-ultrasound has demonstrated success in producing high quality, diagnostically significant images which alter management, decrease time to treatment, and provide more cost-effective care, especially when coupled with supporting data such as electrocardiogram, chest radiography, laboratory results, and clinical history (29, 30, 33, 35, 37, 48).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [37]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Tele-ultrasound has demonstrated success in producing high quality, diagnostically significant images which alter management, decrease time to treatment, and provide more cost-effective care, especially when coupled with supporting data such as electrocardiogram, chest radiography, laboratory results, and clinical history (29, 30, 33, 35, 37, 48).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [37]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spatio‐temporal image correlation (STIC): new technology for evaluation of the fetal heart
DeVore, G. R., Falkensammer, P., Sklansky, M. S., & Platt, L. D. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.217 · Cited by 362
Improving the effectiveness of routine prenatal screening for major congenital heart defects
Carvalho, J. S., Mavrides, E., Shinebourne, E. A., Campbell, S. C., & Thilaganathan, B. (2002) · Heart · doi:10.1136/heart.88.4.387 · Cited by 361
Garne, E., Stoll, C. G., & Clementi, M. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2001.00385.x · Cited by 349
Yagel, S., Weissman, A., Rotstein, Z., Manor, M., Hegesh, J. T., Anteby, E. Y., Lipitz, S., & Achiron, R. (1997) · Circulation · doi:10.1161/01.cir.96.2.550 · Cited by 310
Yagel, S., Cohen, S. M., & Achiron, R. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2001.00414.x · Cited by 299
Stümpflen, I., Stümpflen, A., Wimmer, M., & BERNASCHEK, G. (1996) · The Lancet · doi:10.1016/s0140-6736(96)04069-x · Cited by 292
Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation
Gonçalves, L. F., Lee, W., Chaiworapongsa, T., Espinoza, J., Schoen, M. L., Falkensammer, P., Treadwell, M. C., & Romero, R. J. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(03)00913-x · Cited by 234
Chaoui, R., Hoffmann, J., & Heling, K. S. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1075 · Cited by 233
Viñals, F., Poblete, P., & Giuliano, A. (2003) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.883 · Cited by 192
JAEGGI, E. T., Sholler, G. F., Jones, O. D. H., & Cooper, S. G. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2001.00398.x · Cited by 157
Isolated major congenital heart disease
Ld, A., Benacerraf, B. R., Copel, J. A., Carvalho, J. S., Chaoui, R., Eik‐Nes, S. H., Tegnander, E., Gembruch, U., Huhta, J. C., Pilu, G., et al. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2001.00439.x · Cited by 118
The accuracy of antenatal fetal echocardiography screening in high- and low-risk patients
Ott, W. J. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)91406-4 · Cited by 108
Three cross‐sectional planes for fetal color Doppler echocardiography
Chaoui, R., & McEwing, R. L. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.5 · Cited by 99
Factors influencing the prenatal detection of structural congenital heart diseases
Wong, S. F., Chan, F.-Y., Cincotta, R., Lee‐Tannock, A., & Ward, C. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7 · Cited by 96
Gonçalves, L. F., Romero, R. J., Espinoza, J., Lee, W., Treadwell, M. C., Chintala, K., Hg, B., & Chaiworapongsa, T. (2004) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2004.23.4.473 · Cited by 84
Fisk, N. M., Sepúlveda, W., Drysdale, K., Ridley, D., Garner, P., Bower, S. J., Kyle, P. M., Dhillon, H. K., Carvalho, J. S., & Wootton, R. (1996) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1996.tb09588.x · Cited by 69
Detailed three‐dimensional fetal echocardiography facilitated by an Internet link
Michailidis, G. D., Simpson, J. M., Karidas, C., & Economides, D. L. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.0960-7692.2001.00520.x · Cited by 67
Chan, F.-Y., Soong, B., Lessing, K., Watson, D., Cincotta, R., Baker, S., Smith, M. L., Green, E., & Whitehall, J. S. (2000) · Telemedicine Journal · doi:10.1089/107830200415171 · Cited by 60
Cardiac anatomy screening: what is the best time for screening in pregnancy?
Allan, L. D. (2003) · Current Opinion in Obstetrics & Gynecology · doi:10.1097/00001703-200304000-00009 · Cited by 57
Stoll, C. G., Dott, B., Alembik, Y., & de Geeter, B. (2002) · Annales de Génétique · doi:10.1016/s0003-3995(02)01111-5 · Cited by 34
Networking of three dimensional sonography volume data
Kratochwil, A., Lee, A., & Schoisswohl, A. (2000) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2000.00191.x · Cited by 21
Minimum acceptable standards for digital compression of a fetal ultrasound video-clip
Begg, L. M., Chan, F.-Y., Edie, G., Hockey, R., & Wootton, R. (2001) · Journal of Telemedicine and Telecare · doi:10.1258/1357633011937281 · Cited by 14
Web-based radiology: a future to be created.
Canadè, A., Palladino, F., Pitzalis, G., Campioni, P., & Marano, P. (2003) · PubMed · Cited by 8
Cited by
Sorted by citations
Tele-Ultrasound in Resource-Limited Settings: A Systematic Review
Britton, N., Miller, M. A., Safadi, S., Siegel, A., Levine, A. R., & McCurdy, M. T. (2019) · Frontiers in Public Health · doi:10.3389/fpubh.2019.00244 · Cited by 166
3D and 4D ultrasound in fetal cardiac scanning: a new look at the fetal heart
Yagel, S., Cohen, S. M., Shapiro, I., & Valsky, D. V. (2007) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.3912 · Cited by 173
How do we do it? Practical advice on imaging‐based techniques and investigations
Gonçalves, L. F., Lee, W. S., Espinoza, J., & Romero, R. J. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2724 · Cited by 126
How useful is 3D and 4D ultrasound in perinatal medicine?
Kurjak, A., Mišković, B., Andonotopo, W., Stanojević, M., Azumendi, G., & Vrčić, H. (2007) · Journal of Perinatal Medicine · doi:10.1515/jpm.2007.002 · Cited by 122
Three- and 4-Dimensional Ultrasound in Obstetric Practice
Gonçalves, L. F., Lee, W., Espinoza, J., & Romero, R. J. (2005) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2005.24.12.1599 · Cited by 119
Metadata
- Authors
- Viñals, F., Mandujano, L., Vargas, G., & Giuliano, A.
- Affiliations
- Clínica Alemana (CL)
- Hospital la Serena (CL)
- Corresponding author
- Viñals, F.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2004-12-08
- Volume
- 25
- Issue
- 1
- Pages
- 25-31
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2043946340
- Cited by
- 147
- References
- 23
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 6 · 2018: 4 · 2017: 7 · 2016: 7 · 2015: 8 · 2014: 4 · 2013: 11 · 2012: 10
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Ultrasound in Obstetrics and Gynecology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Fetal Medicine Foundation (1 037 116)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- congenital heart disease, prenatal diagnosis, spatiotemporal image correlation, 4D ultrasound, fetal echocardiography, telemedicine, second opinion, perinatal care
- MeSH terms
- Chile, Developing Countries, Education, Medical, Continuing, Female, Fetal Diseases, Fetal Heart, Heart Defects, Congenital, Humans, Obstetrics, Pilot Projects, Pregnancy, Prospective Studies, Radiology, Ultrasonography, Prenatal, Teleradiology, Echocardiography, Four-Dimensional, Internet
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review