Soluble fms‐like tyrosine kinase‐1 to placental growth factor ratio: ruling out pre‐eclampsia for up to 4 weeks and value of retesting
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objectives: The soluble fms‐like tyrosine kinase‐1 (sFlt‐1) to placental growth factor (PlGF) ratio is generally elevated some time before and at the clinical onset of pre‐eclampsia. The PROGNOSIS study validated a sFlt‐1/PlGF ratio cut‐off of ≤ 38 to rule out the onset of pre‐eclampsia within 1 week of testing in women with suspected disease. The aim of this study was to assess the predictive value of the sFlt‐1/PlGF ratio to rule out the onset of pre‐eclampsia for up to 4 weeks, and to assess the value of repeat measurements. Methods: This was an exploratory post‐hoc analysis of data from the PROGNOSIS study performed in pregnant women aged ≥ 18 years with suspected pre‐eclampsia, who were at 24 + 0 to 36 + 6 weeks' gestation at their first clinic visit. Serum samples were collected at the first visit and weekly thereafter. sFlt‐1 and PlGF levels were measured using Elecsys® sFlt‐1 and PlGF immunoassays. Whether the sFlt‐1/PlGF ratio cut‐off of ≤ 38 used to rule out the onset of pre‐eclampsia within 1 week could predict the absence of pre‐eclampsia 2, 3, and 4 weeks post‐baseline was assessed. The value of repeat sFlt‐1/PlGF testing was assessed by examining the difference in sFlt‐1/PlGF ratio 2 and 3 weeks after the first measurement in women with, and those without, pre‐eclampsia or adverse fetal outcome. Results: On analysis of 550 women, sFlt‐1/PlGF ratio ≤ 38 ruled out the onset of pre‐eclampsia 2 and 3 weeks post‐baseline with high negative predictive values (NPV) of 97.9% and 95.7%, respectively. The onset of pre‐eclampsia within 4 weeks was ruled out with a high NPV (94.3%) and high sensitivity and specificity (66.2% and 83.1%, respectively). Compared with women who did not develop pre‐eclampsia, those who developed pre‐eclampsia had significantly larger median increases in sFlt‐1/PlGF ratio at 2 weeks (∆, 31.22 vs 1.45; P < 0.001) and at 3 weeks (∆, 48.97 vs 2.39; P < 0.001) after their initial visit. Women who developed pre‐eclampsia and/or adverse fetal outcome compared with those who did not had a significantly greater median increase in sFlt‐1/PlGF ratio over the same period (∆, 21.22 vs 1.40; P < 0.001 at 2 weeks; ∆, 34.95 vs 2.30; P < 0.001 at 3 weeks). Conclusion: The Elecsys® immunoassay sFlt‐1/PlGF ratio can help to rule out the onset of pre‐eclampsia for 4 weeks in women with suspected pre‐eclampsia. © 2018 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Global Impact of Pre-eclampsia and Eclampsia
Duley, L. (2009) · Seminars in Perinatology · doi:10.1053/j.semperi.2009.02.010 · Cited by 2,866
Pre-eclampsia rates in the United States, 1980-2010: age-period-cohort analysis
Ananth, C. V., Keyes, K. M., & Wapner, R. J. (2013) · BMJ · doi:10.1136/bmj.f6564 · Cited by 940
Angiogenic factors and the risk of adverse outcomes in women with suspected preeclampsia
Rana, S., Powe, C. E., Salahuddin, S., Verlohren, S., Perschel, F. H., Levine, R. J., Lim, K.-H., Wenger, J. B., Thadhani, R., & Karumanchi, S. A. (2012) · Circulation · doi:10.1161/circulationaha.111.054361 · Cited by 668
Sequential plasma angiogenic factors levels in women with suspected preeclampsia
Baltajian, K., Bajracharya, S., Salahuddin, S., Berg, A. H., Geahchan, C., Wenger, J. B., Thadhani, R., Karumanchi, S. A., & Rana, S. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.01.168 · Cited by 88
Cited by
Rana (2019) · doi:10.1161/circresaha.118.313276 · Cited by 2,095
Pre-eclampsia: pathogenesis, novel diagnostics and therapies
Phipps, E. A., Thadhani, R., Benzing, T., & Karumanchi, S. A. (2019) · Nature Reviews Nephrology · doi:10.1038/s41581-019-0119-6 · Cited by 1,191
Magee, L. A., Brown, M. A., Hall, D. R., Gupte, S., Hennessy, A., Karumanchi, S. A., Kenny, L. C., McCarthy, F., Myers, J., Poon, L. C., et al. (2022) · Pregnancy Hypertension · doi:10.1016/j.preghy.2021.09.008 · Cited by 1,134
Self-citationRana, S., Burke, S. D., & Karumanchi, S. A. (2022) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.10.022 · Cited by 335
Stepan, H., Herraiz, I., Schlembach, D., Verlohren, S., Brennecke, S., Chantraine, F., Klein, E., Lapaire, O., Llurba, E., Ramoni, A., et al. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14799 · Cited by 264
Self-citation
Metadata
- Authors
- Zeisler, H., Llurba, E., Chantraine, F. J., Vatish, M., Staff, A. C., Sennström, M., Olovsson, M., Brennecke, S. P., Stepan, H., Allegranza, D., Schoedl, M., Grill, S., Hund, M., & Verlohren, S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2019-02-04
- Volume
- 53
- Issue
- 3
- Pages
- 367-375
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2911226809
- Cited by
- 144
- References
- 4
- FWCI
- 14.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.