Abstract

Objective: To evaluate the application of artificial intelligence (AI), i.e. deep learning and other machine‐learning techniques, to amniotic fluid (AF) metabolomics and proteomics, alone and in combination with sonographic, clinical and demographic factors, in the prediction of perinatal outcome in asymptomatic pregnant women with short cervical length (CL). Methods: AF samples, which had been obtained in the second trimester from asymptomatic women with short CL (< 15 mm) identified on transvaginal ultrasound, were analyzed. CL, funneling and the presence of AF ‘sludge’ were assessed in all cases close to the time of amniocentesis. A combination of liquid chromatography coupled with mass spectrometry and proton nuclear magnetic resonance spectroscopy‐based metabolomics, as well as targeted proteomics analysis, including chemokines, cytokines and growth factors, was performed on the AF samples. To determine the robustness of the markers, we used six different machine‐learning techniques, including deep learning, to predict preterm delivery < 34 weeks, latency period prior to delivery < 28 days after amniocentesis and requirement for admission to a neonatal intensive care unit (NICU). Omics biomarkers were evaluated alone and in combination with standard sonographic, clinical and demographic factors to predict outcome. Predictive accuracy was assessed using the area under the receiver–operating characteristics curve (AUC) with 95% CI, sensitivity and specificity. Results: Of the 32 patients included in the study, complete omics, demographic and clinical data and outcome information were available for 26. Of these, 11 (42.3%) patients delivered ≥ 34 weeks, while 15 (57.7%) delivered < 34 weeks. There was no statistically significant difference in CL between these two groups (mean ± SD, 11.2 ± 4.4 mm vs 8.9 ± 5.3 mm, P = 0.31). Using combined omics, demographic and clinical data, deep learning displayed good to excellent performance, with an AUC (95% CI) of 0.890 (0.810–0.970) for delivery < 34 weeks' gestation, 0.890 (0.790–0.990) for delivery < 28 days post‐amniocentesis and 0.792 (0.689–0.894) for NICU admission. These values were higher overall than for the other five machine‐learning methods, although each individual machine‐learning technique yielded statistically significant prediction of the different perinatal outcomes. Conclusions: This is the first study to report use of AI with AF proteomics and metabolomics and ultrasound assessment in pregnancy. Machine learning, particularly deep learning, achieved good to excellent prediction of perinatal outcome in asymptomatic pregnant women with short CL in the second trimester. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.20168

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • The length of the cervix and the risk of spontaneous premature delivery

    Iams, J. D., Goldenberg, R. L., Meis, P. J., Mercer, B. M., Moawad, A., Das, A., Thom, E., McNellis, D., Copper, R. L., Johnson, F., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340904 · Cited by 1,894 · cited 1×

    “Ultrasound assessment, including CL measurement 5 , evaluation of the presence of cervical funneling 6 and assessment for cervicovaginal sludge 7 , was performed as previously reported.”
    Method
  • Deep learning for computational biology

    Angermueller, C., Pärnamaa, T., Parts, L., & Stegle, O. (2016) · Molecular Systems Biology · doi:10.15252/msb.20156651 · Cited by 1,473 · cited 1×

    “There are many advantages of DL over other traditional machine-learning algorithms 21,22 , although an in-depth technical/statistical discussion is beyond the scope of this study.”
    Background

Show all 2 references

Cited by

Metadata

Authors
Bahado‐Singh, R. O., Sonek, J., McKenna, D., Cool, D., Aydas, B., Turkoglu, O., Bjorndahl, T., Mandal, R., Wishart, D., Friedman, P., Graham, S. F., & Yilmaz, A.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2019-07
Volume
54
Issue
1
Pages
110-118
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2958239426
Cited by
77
References
2
FWCI
3.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.