Artificial intelligence and amniotic fluid multiomics: prediction of perinatal outcome in asymptomatic women with short cervix
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective: To evaluate the application of artificial intelligence (AI), i.e. deep learning and other machine‐learning techniques, to amniotic fluid (AF) metabolomics and proteomics, alone and in combination with sonographic, clinical and demographic factors, in the prediction of perinatal outcome in asymptomatic pregnant women with short cervical length (CL). Methods: AF samples, which had been obtained in the second trimester from asymptomatic women with short CL (< 15 mm) identified on transvaginal ultrasound, were analyzed. CL, funneling and the presence of AF ‘sludge’ were assessed in all cases close to the time of amniocentesis. A combination of liquid chromatography coupled with mass spectrometry and proton nuclear magnetic resonance spectroscopy‐based metabolomics, as well as targeted proteomics analysis, including chemokines, cytokines and growth factors, was performed on the AF samples. To determine the robustness of the markers, we used six different machine‐learning techniques, including deep learning, to predict preterm delivery < 34 weeks, latency period prior to delivery < 28 days after amniocentesis and requirement for admission to a neonatal intensive care unit (NICU). Omics biomarkers were evaluated alone and in combination with standard sonographic, clinical and demographic factors to predict outcome. Predictive accuracy was assessed using the area under the receiver–operating characteristics curve (AUC) with 95% CI, sensitivity and specificity. Results: Of the 32 patients included in the study, complete omics, demographic and clinical data and outcome information were available for 26. Of these, 11 (42.3%) patients delivered ≥ 34 weeks, while 15 (57.7%) delivered < 34 weeks. There was no statistically significant difference in CL between these two groups (mean ± SD, 11.2 ± 4.4 mm vs 8.9 ± 5.3 mm, P = 0.31). Using combined omics, demographic and clinical data, deep learning displayed good to excellent performance, with an AUC (95% CI) of 0.890 (0.810–0.970) for delivery < 34 weeks' gestation, 0.890 (0.790–0.990) for delivery < 28 days post‐amniocentesis and 0.792 (0.689–0.894) for NICU admission. These values were higher overall than for the other five machine‐learning methods, although each individual machine‐learning technique yielded statistically significant prediction of the different perinatal outcomes. Conclusions: This is the first study to report use of AI with AF proteomics and metabolomics and ultrasound assessment in pregnancy. Machine learning, particularly deep learning, achieved good to excellent prediction of perinatal outcome in asymptomatic pregnant women with short CL in the second trimester. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The length of the cervix and the risk of spontaneous premature delivery
Iams, J. D., Goldenberg, R. L., Meis, P. J., Mercer, B. M., Moawad, A., Das, A., Thom, E., McNellis, D., Copper, R. L., Johnson, F., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340904 · Cited by 1,894 · cited 1×
“Ultrasound assessment, including CL measurement 5 , evaluation of the presence of cervical funneling 6 and assessment for cervicovaginal sludge 7 , was performed as previously reported.”
MethodDeep learning for computational biology
Angermueller, C., Pärnamaa, T., Parts, L., & Stegle, O. (2016) · Molecular Systems Biology · doi:10.15252/msb.20156651 · Cited by 1,473 · cited 1×
“There are many advantages of DL over other traditional machine-learning algorithms 21,22 , although an in-depth technical/statistical discussion is beyond the scope of this study.”
Background
Cited by
Introduction to artificial intelligence in ultrasound imaging in obstetrics and gynecology
Drukker, L., Noble, J. A., & Papageorghiou, A. T. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22122 · Cited by 240
Machine Learning in Fetal Cardiology: What to Expect
Garcia-Canadilla, P., Sanchez-Martinez, S., Crispi, F., & Bijnens, B. (2020) · Fetal Diagnosis and Therapy · doi:10.1159/000505021 · Cited by 123
Dhombres, F., Bonnard, J., Bailly, K., Maurice, P., Papageorghiou, A. T., & Jouannic, J.-M. (2022) · Journal of Medical Internet Research · doi:10.2196/35465 · Cited by 93
Use of artificial intelligence in obstetrics: Not quite ready for prime time
Sarno, L., Neola, D., Carbone, L., Saccone, G., Carlea, A., Miceli, M., Iorio, G. G., Mappa, I., Rizzo, G., Girolamo, R. D., et al. (2023) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2022.100792 · Cited by 47
Accuracy of automated three-dimensional ultrasound imaging technique for fetal head biometry
Pluym, I. D., Afshar, Y., Holliman, K., Kwan, L., Bolagani, A., Mok, T., Silver, B., Ramirez, E., Han, C. S., & Platt, L. D. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22171 · Cited by 46
Machine learning and disease prediction in obstetrics
Arain, Z., Iliodromiti, S., Slabaugh, G., David, A. L., & Chowdhury, T. T. (2023) · Current Research in Physiology · doi:10.1016/j.crphys.2023.100099 · Cited by 40
Metadata
- Authors
- Bahado‐Singh, R. O., Sonek, J., McKenna, D., Cool, D., Aydas, B., Turkoglu, O., Bjorndahl, T., Mandal, R., Wishart, D., Friedman, P., Graham, S. F., & Yilmaz, A.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2019-07
- Volume
- 54
- Issue
- 1
- Pages
- 110-118
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2958239426
- Cited by
- 77
- References
- 2
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.