Cited by 47Fetal and Pediatric Neurological DisordersPrenatal Screening and DiagnosticsArtificial Intelligence in Healthcare and Education

Accuracy of automated three-dimensional ultrasound imaging technique for fetal head biometry

Open access
Pluym, I. D., Afshar, Y., Holliman, K., Kwan, L., Bolagani, A., Mok, T., Silver, B., Ramirez, E. +2 more·2021·Ultrasound in Obstetrics & Gynecology

Abstract

OBJECTIVES: To evaluate the accuracy of an automated three-dimensional (3D) ultrasound technique for fetal intracranial measurements compared with manual acquisition. METHODS: This was a prospective observational study of patients presenting for routine anatomical survey between 18 + 0 and 22 + 6 weeks' gestation. After providing informed consent, each patient underwent two consecutive ultrasound examinations of the fetal head, one by a sonographer and one by a physician. Each operator obtained manual measurements of the biparietal diameter (BPD), head circumference (HC), transcerebellar diameter (TCD), cisterna magna (CM) and posterior horn of the lateral ventricle (Vp), followed by automated measurements of these structures using an artificial intelligence-based tool, SonoCNS® Fetal Brain. Both operators repeated the automated approach until all five measurements were obtained in a single sweep, up to a maximum of three attempts. The accuracy of automated measurements was compared with that of manual measurements using intraclass correlation coefficients (ICC) by operator type, accounting for patient and ultrasound characteristics. RESULTS: ) and median subcutaneous thickness was 1.6 cm (IQR, 1.3-2.0 cm). Fifteen (10%) patients had at least one prior Cesarean delivery, 17 (12%) had other abdominal surgery and 78 (55%) had an anterior placenta. Successful acquisition of the automated measurements was achieved on the first, second and third attempts in 70%, 22% and 3% of patients, respectively, by sonographers and in 76%, 16% and 3% of cases, respectively, by physicians. The automated algorithm was not able to identify and measure all five structures correctly in six (4%) and seven (5%) patients scanned by the sonographers and physicians, respectively. The ICCs reflected good reliability (0.80-0.88) of the automated compared with the manual approach for BPD and HC and poor to moderate reliability (0.23-0.50) for TCD, CM and Vp. Fetal lie, head position, placental location, maternal subcutaneous thickness and prior Cesarean section were not associated with the success or accuracy of the automated technique. CONCLUSIONS: Automated 3D ultrasound imaging of the fetal head using SonoCNS reliably identified and measured BPD and HC but was less consistent in accurately identifying and measuring TCD, CM and Vp. While these results are encouraging, further optimization of the automated technology is necessary prior to incorporation of the technique into routine sonographic protocols. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.22171

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 29 references couldn’t be matched to a known paper.

Research works printed but not linked: 1

  1. Martin JA, Hamilton BE, Osterman MJK. Births in the United States, 2018. NCHS Data Brief 2019; 346: 1-8.

Cited by

Sorted by citations

Authors
Pluym, I. D., Afshar, Y., Holliman, K., Kwan, L., Bolagani, A., Mok, T., Silver, B., Ramirez, E., Han, C. S., & Platt, L. D.
Affiliations
  • University of California, Los Angeles (US)
  • Center for Fetal Medicine and Women's Ultrasound Los Angeles CA USA
Corresponding author
Pluym, I. D.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2021-05
Volume
57
Issue
5
Pages
798-803
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W3048235968
Cited by
46
References
29
Citations by year
2026: 5 · 2025: 9 · 2024: 10 · 2023: 11 · 2022: 5 · 2021: 6
FWCI
5.28
Type
journal article
Language
en
Open access
Locations
  • Ultrasound in Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Fetal and Pediatric Neurological Disorders
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
biparietal diameter, head circumference, transverse cerebellar diameter, cisterna magna, artificial intelligence in ultrasound, measurement accuracy, manual vs automated measurement, placental location, previous cesarean section
MeSH terms
Adult, Artificial Intelligence, Biometry, Female, Fetus, Gestational Age, Head, Humans, Pregnancy, Prospective Studies, Reproducibility of Results, Ultrasonography, Prenatal, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review