The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Accuracy of cervical transvaginal sonography in predicting preterm birth: a systematic review
Abstract
This review investigates the accuracy with which transvaginal cervical sonography predicts spontaneous preterm birth. Published studies were identified without language restrictions through nine different databases and manual searching of bibliographies of known primary and review articles. Studies were selected if they undertook antenatal transvaginal sonographic cervical assessment among a population of pregnant women with known gestational age of delivery. There were 46 primary articles, which included a total of 31 577 women, consisting of 33 studies in asymptomatic and 13 studies in symptomatic women. Data were extracted for the studies' characteristics and quality. Accuracy data were used to form 2 × 2 contingency tables for various cervical length measurements with birth before 32, 34 and 37 weeks' gestation as the reference standards. Data were stratified according to singleton or twin pregnancy, gestational age at testing, cervical length threshold, and the various reference standards, and were pooled to produce summary estimates of likelihood ratios (LRs). Our review showed that transvaginal cervical sonography identifies women who are at higher risk of spontaneous preterm birth, although there was a wide variation amongst studies with respect to gestational age at testing, definition of threshold of abnormality and definition of reference standard. The most commonly reported sub‐group was testing of asymptomatic women at < 20 weeks' gestation using a threshold cervical length of 25 mm with spontaneous preterm birth before 34 weeks' gestation as the reference standard. The summary LR+ for this group was 6.29 (95% CI, 3.29–12.02), with corresponding LR− of 0.79 (95% CI, 0.65–0.95). Both cervical length measurement and funneling, whether alone or in combination, appear to be useful (depending on the threshold chosen to define the abnormality) in predicting spontaneous preterm birth in asymptomatic women. For symptomatic women there was a paucity of data, although the degree of funneling appeared to be predictive of spontaneous preterm birth. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The length of the cervix and the risk of spontaneous premature delivery
Iams, J. D., Goldenberg, R. L., Meis, P. J., Mercer, B. M., Moawad, A., Das, A., Thom, E., McNellis, D., Copper, R. L., Johnson, F., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340904 · Cited by 1,894
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Leitich, H., Brunbauer, M., Kaider, A., Egarter, C., & Husslein, P. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70407-2 · Cited by 178
Cited by
Romero, R., Nicolaides, K., Conde-Agudelo, A., Tabor, A., O'Brien, J. M., Cetingoz, E., Da Fonseca, E., Creasy, G. W., Klein, K., Rode, L., et al. (2012) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.12.003 · Cited by 580
Romero, R., Conde-Agudelo, A., Da Fonseca, E., O’Brien, J. M., Cetingoz, E., Creasy, G. W., Hassan, S. S., & Nicolaides, K. H. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.11.576 · Cited by 522
Prediction and Prevention of Spontaneous Preterm Birth
(2021) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000004479 · Cited by 377
MENON, R. (2008) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1080/00016340802005126 · Cited by 337
Dodd, J. M., Jones, L., Flenady, V., Cincotta, R., & Crowther, C. A. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004947.pub3 · Cited by 331
Crane, J. M. G., & Hutchens, D. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5323 · Cited by 279
Conde-Agudelo, A., Romero, R., Hassan, S. S., & Yeo, L. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.02.064 · Cited by 256
Conde-Agudelo, A., Romero, R., Da Fonseca, E., O’Brien, J. M., Cetingoz, E., Creasy, G. W., Hassan, S. S., Erez, O., Pacora, P., & Nicolaides, K. H. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.03.028 · Cited by 168
Metadata
- Authors
- Honest, H., Bachmann, L. M., Coomarasamy, A., Gupta, J. K., Kleijnen, J., & Khan, K. S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2003-08-13
- Volume
- 22
- Issue
- 3
- Pages
- 305-322
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2067554705
- Cited by
- 206
- References
- 3
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.