Why are congenital heart defects being missed?
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Objective: Congenital heart defects (CHD) are still missed frequently in prenatal screening programs, which can result in severe morbidity or even death. The aim of this study was to evaluate the quality of fetal heart images, obtained during the second‐trimester standard anomaly scan (SAS) in cases of CHD, to explore factors associated with a missed prenatal diagnosis. Methods: In this case–control study, all cases of a fetus born with isolated severe CHD in the Northwestern region of The Netherlands, between 2015 and 2016, were extracted from the PRECOR registry. Severe CHD was defined as need for surgical repair in the first year postpartum. Each cardiac view (four‐chamber view (4CV), three‐vessel (3V) view and left and right ventricular outflow tract (LVOT, RVOT) views) obtained during the SAS was scored for technical correctness on a scale of 0 to 5 by two fetal echocardiography experts, blinded to the diagnosis of CHD and whether it was detected prenatally. Quality parameters of the cardiac examination were compared between cases in which CHD was detected and those in which it was missed on the SAS. Regression analysis was used to assess the association of sonographer experience and of screening‐center experience with the cardiac examination quality score. Results: A total of 114 cases of isolated severe CHD at birth were analyzed, of which 58 (50.9%) were missed and 56 (49.1%) were detected on the SAS. The defects comprised transposition of the great arteries (17%), aortic coarctation (16%), tetralogy of Fallot (10%), atrioventricular septal defect (6%), aortic valve stenosis (5%), ventricular septal defect (18%) and other defects (28%). No differences were found in fetal position, obstetric history, maternal age or body mass index (BMI) or gestational age at examination between missed and detected cases. Ninety‐two cases had available cardiac images from the SAS. Compared with the detected group, the missed group had significantly lower cardiac examination quality scores (adequate score (≥ 12) in 32% vs 64%; P = 0.002), rate of proper use of magnification (58% vs 84%; P = 0.01) and quality scores for each individual cardiac plane (4CV (2.7 vs 3.9; P < 0.001), 3V view (3.0 vs 3.8; P = 0.02), LVOT view (1.9 vs 3.3; P < 0.001) and RVOT view (1.9 vs 3.3; P < 0.001)). In 49% of missed cases, the lack of detection was due to poor adaptational skills resulting in inadequate images in which the CHD was not clearly visible; in 31%, the images showed an abnormality (mainly septal defects and aortic arch anomalies) which had not been recognized at the time of the scan; and, in 20%, the cardiac planes had been obtained properly but showed normal anatomy. Multivariate regression analysis showed that the volume of SAS performed per year by each sonographer was associated significantly with quality score of the cardiac examination. Conclusions: A lack of adaptational skills when performing the SAS, as opposed to circumstantial factors such as BMI or fetal position, appears to play an important role in failure to detect CHD prenatally. The quality of the cardiac views was inadequate significantly more often in undetected compared with detected cases. Despite adequate quality of the images, CHD was not recognized in 31% of cases. A high volume of SAS performed by each sonographer in a large ultrasound center contributes significantly to prenatal detection. In 20% of undetected cases, CHD was not visible even though the quality of the images was good. © 2019 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Prenatal detection of congenital heart disease—results of a national screening programme
van Velzen, C., Clur, S., Rijlaarsdam, M., Bax, C., Pajkrt, E., Heymans, M., Bekker, M., Hruda, J., de Groot, C., Blom, N., et al. (2016) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13274 · Cited by 240
Self-citationClinicians’ gut feeling about serious infections in children: observational study.
Van den Bruel, A., Thompson, M., Buntinx, F., & Mant, D. (2012) · BMJ · doi:10.1136/bmj.e6144 · Cited by 183
Lytzen, R., Vejlstrup, N., Bjerre, J., Petersen, O. B., Leenskjold, S., Dodd, J. K., Jørgensen, F. S., & Søndergaard, L. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.2009 · Cited by 169
Peyvandi, S., De Santiago, V., Chakkarapani, E., Chau, V., Campbell, A., Poskitt, K. J., Xu, D., Barkovich, A. J., Miller, S., & McQuillen, P. (2016) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2015.4450 · Cited by 167
Calderon, J., Angeard, N., Moutier, S., Plumet, M.-H., Jambaqué, I., & Bonnet, D. (2012) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2011.12.036 · Cited by 156
van Velzen, C. L., Ket, J. C. F., van de Ven, P. M., Blom, N. A., & Haak, M. C. (2018) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.12373 · Cited by 115
Self-citationQuartermain, M. D., Hill, K. D., Goldberg, D. J., Jacobs, J. P., Jacobs, M. L., Pasquali, S. K., Verghese, G. R., Wallace, A. S., & Ungerleider, R. M. (2019) · Pediatric Cardiology · doi:10.1007/s00246-018-1995-4 · Cited by 68
Everwijn, S. M. P., van Nisselrooij, A. E. L., Rozendaal, L., Clur, S. B., Pajkrt, E., Hruda, J., Linskens, I. H., van Lith, J. M., Blom, N. A., & Haak, M. C. (2018) · Prenatal Diagnosis · doi:10.1002/pd.5347 · Cited by 33
Self-citation
Cited by
Use of artificial intelligence and deep learning in fetal ultrasound imaging
Ramirez Zegarra, R., & Ghi, T. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26130 · Cited by 102
Deep learning-based real time detection for cardiac objects with fetal ultrasound video
Iriani Sapitri, A., Nurmaini, S., Naufal Rachmatullah, M., Tutuko, B., Darmawahyuni, A., Firdaus, F., Rini, D. P., & Islami, A. (2023) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2022.101150 · Cited by 42
Exploring a new paradigm for the fetal anomaly ultrasound scan: Artificial intelligence in real time
Matthew, J., Skelton, E., Day, T. G., Zimmer, V. A., Gomez, A., Wheeler, G., Toussaint, N., Liu, T., Budd, S., Lloyd, K., et al. (2022) · Prenatal Diagnosis · doi:10.1002/pd.6059 · Cited by 41
Artificial intelligence in perinatal diagnosis and management of congenital heart disease
Reddy, C. D., Van den Eynde, J., & Kutty, S. (2022) · Seminars in Perinatology · doi:10.1016/j.semperi.2022.151588 · Cited by 32
Karim, J. N., Campbell, H., Pandya, P., Wilson, E. C. F., Alfirevic, Z., Chudleigh, T., Duff, E., Fisher, J., Goodman, H., Hinton, L., et al. (2025) · Health Technology Assessment · doi:10.3310/nltp7102 · Cited by 5
Metadata
- Authors
- van Nisselrooij, A. E. L., Teunissen, A. K. K., Clur, S. A., Rozendaal, L., Pajkrt, E., Linskens, I. H., Rammeloo, L., van Lith, J. M. M., Blom, N. A., & Haak, M. C.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2020-06
- Volume
- 55
- Issue
- 6
- Pages
- 747-757
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2947973440
- Cited by
- 158
- References
- 9
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.