Objective: Congenital heart defects (CHD) are still missed frequently in prenatal screening programs, which can result in severe morbidity or even death. The aim of this study was to evaluate the quality of fetal heart images, obtained during the second‐trimester standard anomaly scan (SAS) in cases of CHD, to explore factors associated with a missed prenatal diagnosis. Methods: In this case–control study, all cases of a fetus born with isolated severe CHD in the Northwestern region of The Netherlands, between 2015 and 2016, were extracted from the PRECOR registry. Severe CHD was defined as need for surgical repair in the first year postpartum. Each cardiac view (four‐chamber view (4CV), three‐vessel (3V) view and left and right ventricular outflow tract (LVOT, RVOT) views) obtained during the SAS was scored for technical correctness on a scale of 0 to 5 by two fetal echocardiography experts, blinded to the diagnosis of CHD and whether it was detected prenatally. Quality parameters of the cardiac examination were compared between cases in which CHD was detected and those in which it was missed on the SAS. Regression analysis was used to assess the association of sonographer experience and of screening‐center experience with the cardiac examination quality score. Results: A total of 114 cases of isolated severe CHD at birth were analyzed, of which 58 (50.9%) were missed and 56 (49.1%) were detected on the SAS. The defects comprised transposition of the great arteries (17%), aortic coarctation (16%), tetralogy of Fallot (10%), atrioventricular septal defect (6%), aortic valve stenosis (5%), ventricular septal defect (18%) and other defects (28%). No differences were found in fetal position, obstetric history, maternal age or body mass index (BMI) or gestational age at examination between missed and detected cases. Ninety‐two cases had available cardiac images from the SAS. Compared with the detected group, the missed group had significantly lower cardiac examination quality scores (adequate score (≥ 12) in 32% vs 64%; P = 0.002), rate of proper use of magnification (58% vs 84%; P = 0.01) and quality scores for each individual cardiac plane (4CV (2.7 vs 3.9; P < 0.001), 3V view (3.0 vs 3.8; P = 0.02), LVOT view (1.9 vs 3.3; P < 0.001) and RVOT view (1.9 vs 3.3; P < 0.001)). In 49% of missed cases, the lack of detection was due to poor adaptational skills resulting in inadequate images in which the CHD was not clearly visible; in 31%, the images showed an abnormality (mainly septal defects and aortic arch anomalies) which had not been recognized at the time of the scan; and, in 20%, the cardiac planes had been obtained properly but showed normal anatomy. Multivariate regression analysis showed that the volume of SAS performed per year by each sonographer was associated significantly with quality score of the cardiac examination. Conclusions: A lack of adaptational skills when performing the SAS, as opposed to circumstantial factors such as BMI or fetal position, appears to play an important role in failure to detect CHD prenatally. The quality of the cardiac views was inadequate significantly more often in undetected compared with detected cases. Despite adequate quality of the images, CHD was not recognized in 31% of cases. A high volume of SAS performed by each sonographer in a large ultrasound center contributes significantly to prenatal detection. In 20% of undetected cases, CHD was not visible even though the quality of the images was good. © 2019 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.20358

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 158

Metadata

Authors
van Nisselrooij, A. E. L., Teunissen, A. K. K., Clur, S. A., Rozendaal, L., Pajkrt, E., Linskens, I. H., Rammeloo, L., van Lith, J. M. M., Blom, N. A., & Haak, M. C.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2020-06
Volume
55
Issue
6
Pages
747-757
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2947973440
Cited by
158
References
9
FWCI
7.78
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.