Cited by 42Medical Image Segmentation TechniquesAdvanced Neural Network ApplicationsArtificial Intelligence in Healthcare and Education

Deep learning-based real time detection for cardiac objects with fetal ultrasound video

Open access
Iriani Sapitri, Ade, Nurmaini, Siti, Naufal Rachmatullah, Muhammad, Tutuko, Bambang, Darmawahyuni, Annisa, Firdaus, Firdaus, Rini, Dian Palupi, Islami, Anggun·2023·Informatics in Medicine Unlocked

Abstract

Fetal cardiac anatomical structure interpretation by ultrasound (US) is a key part of prenatal assessment. Unfortunately, the numerous speckles in US video, the small size of fetal cardiac structures, and unfixed fetal positions make manual detection processes difficult. To alleviate such problems, a deep learning model was developed to fully automate the processing of fetal echocardiographs with 2-dimensional cross-sectional images. The weakness of such an approach is that a physician immediately interprets US video with 3-dimensional objects to diagnose patients in clinical practice. To improve fetal cardiac anatomical structure interpretation via US for accurate and real time diagnosis, this paper proposes a real-time fetal cardiac substructure detection using US video with the You Only Look Once (YOLO) framework. In YOLO, an end-to-end neural network makes predictions for cardiac substructure objects, boxes, and class probabilities simultaneously. To achieve reliable performance, 40 fetal echocardiography videos were trained with the new YOLOv7 architecture and fine-tuned to work optimally and run efficiently. We conducted with nine fetal cardiac substructure objects such as the left atrium, right atrium, left ventricle, right ventricle, tricuspid valve, pulmonary valve, mitral valve, aortic valve, and aorta. The results yielded the highest mean average precision of 82.10%, reaching 17 frames per second (FPS) for nine cardiac substructure objects in 0.3 ms. The main finding of our study is that with even a limited number of US videos, YOLOv7 can detect fetal cardiac substructure objects in real-time. Such a network can work efficiently to detect small fetal cardiac objects automatically in a rapid phase with the help of proper fine-tuning. This work mainly assists medical experts in the fetal cardiac anatomy diagnostic process.

Integrity signals

Registry

Crossref · 10.1016/j.imu.2022.101150

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Authors
Iriani Sapitri, A., Nurmaini, S., Naufal Rachmatullah, M., Tutuko, B., Darmawahyuni, A., Firdaus, F., Rini, D. P., & Islami, A.
Affiliations
Sriwijaya University (ID)
Corresponding author
Nurmaini, Siti
Venue
Informatics in Medicine Unlocked
Publisher
Elsevier BV
Published
2023
Volume
36
Pages
101150
ISSN
2352-9148 (ISSN-L)
OpenAlex
W4311907047
Cited by
42
References
6
Citations by year
2026: 5 · 2025: 11 · 2024: 13 · 2023: 13
FWCI
3.03
Type
journal article
Language
en
Open access
Locations
  • Informatics in Medicine Unlocked (publishedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Universitas Sriwijaya
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
fetal echocardiography, real-time object detection, YOLOv7, ultrasound video, cardiac anatomy, left atrium, right atrium, left ventricle, right ventricle, heart valves, aorta, fine-tuning, prenatal diagnosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review