Assessment of the intraobserver variability in the measurement of fetal cardiothoracic ratio using ellipse and diameter methods

Awadh, A. M. A., Prefumo, F., Bland, J. M., Carvalho, J. S.·2006·Ultrasound in Obstetrics & Gynecology

Abstract

OBJECTIVE: To assess the variability of fetal heart and thoracic area and circumference measurements using the ellipse and diameter methods at different gestational ages. DESIGN: This was a prospective cross-sectional study of 200 singleton pregnancies, with no apparent fetal abnormalities. The gestational age ranged between 19 and 42 weeks. At each examination, two transverse frames of the fetal chest at the level of the four-chamber view during diastole were obtained. For each frame, the area and the circumference of the heart and thorax were obtained by the ellipse and diameter methods. In the diameter method, cardiac and thoracic areas and circumferences were derived from the measured anteroposterior and transverse diameters. All measurements were made by the same observer. RESULTS: For the same method, intraobserver variability was good. Coefficient of variation for all measurements varied between 3-11%. The ellipse method tended to give larger measurements than did the diameter method, the absolute difference increasing with fetal age. The mean ellipse/diameter ratio was 1.10, 1.04, 1.05 and 1.02 for heart area, thorax area, heart circumference and thorax circumference, respectively. In most cases, intraobserver variability of the thorax measurements was independent of gestational age. In contrast, there was a greater variability of heart measurements with increasing gestational age. CONCLUSIONS: Both the ellipse and diameter methods of measuring cardiothoracic ratio are clinically useful and fairly reproducible at certain gestations, but are not interchangeable as the ellipse method overestimates measurements compared to the diameter method. The less reproducible measurement of heart size in later gestation should be taken into account when assessing cardiothoracic ratios.

Integrity signals

Registry

Crossref · 10.1002/uog.2813

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The cardiothoracic area ratio, the ratio of the area of the heart and the thorax on 4CV, is a representative indicator of congenital heart diseases (CHDs) and fetal heart failure.

    “the cardiothoracic area ratio, the ratio of the area of the heart and the thorax on 4CV, is a representative indicator of congenital heart diseases (CHDs) and fetal heart failure [35,36].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Awadh, A. M. A., Prefumo, F., Bland, J. M., & Carvalho, J. S.
Affiliations
  • St George's, University of London (GB)
  • Royal Brompton Hospital (GB)
Corresponding author
Awadh, A. M. A.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2006-06-06
Volume
28
Issue
1
Pages
53-56
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2128222395
Cited by
50
References
11
Citations by year
2026: 1 · 2024: 2 · 2023: 3 · 2022: 6 · 2021: 4 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 5 · 2013: 4 · 2012: 2
FWCI
0.49
Type
journal article
Language
en
Open access
closed
Locations
  • Ultrasound in Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
  • Institutional Research Information System (Università degli Studi di Brescia) (submittedVersion)
Topics
  • Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
Keywords
intraobserver variability, fetal heart size, ellipse method, fetal biometry, gestational age, measurement reproducibility, fetal echocardiography
MeSH terms
Adult, Analysis of Variance, Cross-Sectional Studies, Female, Fetal Heart, Gestational Age, Humans, Pregnancy, Prospective Studies, Reproducibility of Results, Observer Variation, Ultrasonography, Prenatal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review