Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record.

Intrapartum translabial ultrasound (ITU): sonographic landmarks and correlation with successful vacuum extraction

Open access
Henrich, W., Dudenhausen, J., Fuchs, I., Kämena, A., Tutschek, B.·2006·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: Having studied intrapartum translabial ultrasound (ITU) to define easily obtainable sonographic criteria during maternal pushing, we used it dynamically immediately before vacuum extraction to determine its use in predicting successful operative vaginal delivery. Methods: In a pilot study, maternal and fetal landmarks were determined sonographically during maternal pushing from a mid‐sagittal translabial insonation using a curved array transducer in women delivering singleton fetuses in cephalic presentation spontaneously. With this transducer placed infrapubically (‘infrapubic plane’), easily obtainable landmarks and signs were: (i) the ‘infrapubic line’, perpendicular to the long axis of the pubic joint and extending dorsally from its inferior margin in a mid‐sagittal plane, (ii) the widest fetal head diameter and its movement with regard to the infrapubic line during pushing, and (iii) the ‘head direction’ with respect to the long axis of the symphysis. A three‐dimensional reconstruction from a computed tomographic (CT) dataset of a normal female pelvis was then used to quantify accurately the spatial relationship between the infrapubic line and the anatomical landmarks. Finally, 20 pregnant women in spontaneous term labor with normal singleton fetuses in cephalic presentation and clinical indication for vacuum extraction were studied by ITU immediately before operative vaginal delivery. Results: CT reconstruction demonstrated the infrapubic line to be 3 cm cranial to the parallel interspinous plane. Eleven of the 20 vacuum deliveries with the ‘head‐up’ sign (head pointing ventrally) and objective descent of the fetal head below the infrapubic line, both noted at the height of pushing, resulted in successful (‘simple’ or ‘moderately difficult’) operative delivery. Lack of descent or lack of passage below the infrapubic line and horizontal or downward head direction were poor prognostic signs. Conclusions: ITU provides objective information on the dynamics of the second stage of labor, head station and head direction. ITU may be used to assess the prognosis for operative vaginal delivery. Copyright © 2006 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.3848

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 245

Metadata

Authors
Henrich, W., Dudenhausen, J., Fuchs, I., Kämena, A., & Tutschek, B.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2006-10-24
Volume
28
Issue
6
Pages
753-760
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1986355026
Cited by
245
References
0
FWCI
8.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intrapartum translabial ultrasound (ITU): sonographic landmarks and correlation with successful vacuum extraction. https://app.cochat.ai/papers/10.1002/uog.3848
The paper
Henrich, W., Dudenhausen, J., Fuchs, I., Kämena, A., & Tutschek, B. (2006). Intrapartum translabial ultrasound (ITU): sonographic landmarks and correlation with successful vacuum extraction. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.3848

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.