Test characteristics of placental location screening by transabdominal ultrasound at 18–20 weeks
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objectives: To determine the test characteristics of a second‐trimester transabdominal fetal anomaly scan in screening for placenta previa. Patients and methods: This was a case‐control study carried out at a tertiary obstetric hospital involving 54 women (0.5% of the total number booked for antenatal care and delivery at the center) with clinically significant placenta previa at the time of delivery, and 168 randomly selected controls who attended for antenatal care and delivery in 2000–2003. Sensitivity, specificity and false positive rate of the placenta–os measurement in the second‐trimester transabdominal fetal anomaly scan for identification of clinically significant placenta previa were assessed. Results: Women with placenta previa at delivery had significantly different second‐trimester placenta–os measurements from those of controls (P < 0.0001). For women with placenta previa, the mean (standard deviation) placenta–os measurement was −0.96 cm (1.95) vs. 4.15 cm (1.77) for controls (P < 0.0001). Using the anomaly scan as a screening test for placenta previa with a placenta–os measurement cut‐off point of ≤ 2 cm, all cases of placenta previa should be identified, but 11.1% (95% CI, 7.1–14.8) of women without placenta previa would have false positive results. At cut‐off points of 3 cm and 1.5 cm the false positive rates were 25.7% (95% CI, 18.8–30.2%) and 6.6% (95% CI, 3.8–9.6%), respectively, but at 1.5 cm 3.8% of cases would be missed. Conclusions: The second‐trimester transabdominal fetal anomaly scan is a useful screening test for placenta previa. However, because of false positives among the much larger population of women without placenta previa, we estimate that with a cut‐off point of ≤2 cm, 23 women would have to be followed up to confirm one true placenta previa. Copyright © 2006 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics Notes: Diagnostic tests 2: predictive values
Altman, D. G., & Bland, J. M. (1994) · BMJ · doi:10.1136/bmj.309.6947.102 · Cited by 1,711
Becker, R. H., Vonk, R., Mende, B. C., Ragosch, V., & Entezami, M. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00423.x · Cited by 175
Smith, R. S., Lauria, M. R., Comstock, C. H., Treadwell, M. C., Kirk, J. S., Lee, W., & Bottoms, S. F. (1997) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1997.09010022.x · Cited by 116
The use of second‐trimester transvaginal sonography to predict placenta previa
Lauria, M. R., Smith, R. S., Treadwell, M. C., Comstock, C. H., Kirk, J. S., Lee, W., & Bottoms, S. F. (1996) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1996.08050337.x · Cited by 93
Transvaginal ultrasonography at 18–23 weeks in predicting placenta previa at delivery
Taipale, P., Hiilesmaa, V., & Ylöstalo, P. (1998) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1998.12060422.x · Cited by 79
Cited by
Prevalence of placenta praevia by world region: a systematic review and meta‐analysis
Cresswell, J. A., Ronsmans, C., Calvert, C., & Filippi, V. (2013) · Tropical Medicine & International Health · doi:10.1111/tmi.12100 · Cited by 246
Transabdominal Ultrasonography as a Screening Test for Second-Trimester Placenta Previa
Quant, H. S., Friedman, A. M., Wang, E., Parry, S., & Schwartz, N. (2014) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000129 · Cited by 34
Final outcome of a second trimester low-positioned placenta: A systematic review and meta-analysis
Jansen, C. H. J. R., Kleinrouweler, C. E., van Leeuwen, L., Ruiter, L., Limpens, J., van Wely, M., Mol, B. W., & Pajkrt, E. (2019) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2019.06.020 · Cited by 23
Precise mid‐trimester placenta localisation: Does it predict adverse outcomes?
Robinson, A. J., Muller, P. R., Allan, R., Ross, R., Baghurst, P. A., & Keirse, M. J. N. C. (2012) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.2012.01416.x · Cited by 21
Low‐lying placenta: Who should be recalled for a follow‐up scan?
Copland, J. A., Craw, S. M., & Herbison, P. (2012) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/j.1754-9485.2012.02350.x · Cited by 19
Kapoor, S., Thomas, J. T., Petersen, S. G., & Gardener, G. J. (2014) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/ajo.12244 · Cited by 12
Metadata
- Authors
- Olive, E. C., Roberts, C. L., Nassar, N., & Algert, C. S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2006-11-23
- Volume
- 28
- Issue
- 7
- Pages
- 944-949
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1992918573
- Cited by
- 18
- References
- 5
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.