Transabdominal Ultrasonography as a Screening Test for Second-Trimester Placenta Previa
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the test characteristics of transabdominal ultrasonography as a screening test for second-trimester placenta previa. METHODS: This secondary analysis of a prospective cohort study evaluated the distance from the placental edge to the internal os (placenta-cervix distance) through both transabdominal and transvaginal ultrasonography during the anatomic survey. Patients were recruited in the Maternal-Fetal Medicine Ultrasound Unit at the Hospital of the University of Pennsylvania, an urban tertiary care center. Transabdominal placenta-cervix distance cutoffs with high sensitivity for detection of previa and low-lying placenta were identified, and test characteristics were calculated. Follow-up ultrasound data, pregnancy, and delivery outcomes for those with second-trimester previa or low-lying placenta were obtained. RESULTS: One thousand two hundred fourteen women were included in the analysis. A transabdominal placenta-cervix distance cutoff of 4.2 cm was 93.3% sensitive and 76.7% specific for detection of previa with a 99.8% negative predictive value at a screen-positive rate of 25.0%. A cutoff of 2.8 cm was 86.7% sensitive and 90.5% specific with a 99.6% negative predictive value at a screen-positive rate of 11.4%. Only 9.8% (four of 41) of previas and low-lying placentas persisted through delivery. CONCLUSION: Transabdominal ultrasonography is an effective screening test for second-trimester placenta previa. At centers not performing universal transvaginal ultrasonography at the time of the anatomic survey, evidence-based transabdominal placenta-cervix distance cutoffs can optimize the identification of patients who require further surveillance for previa.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006
Persistence of Placenta Previa According to Gestational Age at Ultrasound Detection
Dashe, J. S., McIntire, D. D., Ramus, R. M., Santos-Ramos, R., & Twickler, D. M. (2002) · Obstetrics & Gynecology · doi:10.1097/00006250-200205000-00005 · Cited by 242
MATERNAL COMPLICATIONS WITH PLACENTA PREVIA
Crane, J. M. G., Van den Hof, M. C., Dodds, L., Armson, B. A., & Liston, R. (2000) · American Journal of Perinatology · doi:10.1055/s-2000-9269 · Cited by 207
Neonatal outcomes with placenta previa
Crane, J. (1999) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(98)00480-3 · Cited by 197
Accuracy and Safety of Transvaginal Sonographic Placental Localization
LEERENTVELD, R. A., GILBERTS, E. C. A. M., ARNOLD, M. J. C. W. J., & WLADIMIROFF, J. W. (1990) · Obstetrics & Gynecology · doi:10.1097/00006250-199011000-00006 · Cited by 179
Becker, R. H., Vonk, R., Mende, B. C., Ragosch, V., & Entezami, M. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00423.x · Cited by 175
Ananth, C. V., Smulian, J. C., & Vintzileos, A. M. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2003.76 · Cited by 147
Confirming the safety of transvaginal sonography in patients suspected of placenta previa.
Timor‐Tritsch, I. E., & Yunis, R. A. (1993) · PubMed · Cited by 133
Smith, R. S., Lauria, M. R., Comstock, C. H., Treadwell, M. C., Kirk, J. S., Lee, W., & Bottoms, S. F. (1997) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1997.09010022.x · Cited by 116 · cited 1×
“Transvaginal ultrasonography may be particularly useful in the detection of posterior previa(12,13) and previa in obese women.(8) Some authors have promoted transabdominal ultrasonography for routine placental localization, reserving transvaginal ultrasonography for cases in which the placenta appears close to the cer…”
BackgroundThe use of second‐trimester transvaginal sonography to predict placenta previa
Lauria, M. R., Smith, R. S., Treadwell, M. C., Comstock, C. H., Kirk, J. S., Lee, W., & Bottoms, S. F. (1996) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1996.08050337.x · Cited by 93
Research works printed but not linked: 4
- Sherman, 1992, Transvaginal ultrasound: does it help in the diagnosis of placenta previa Ultrasound Obstet G, ynecol, 2, 256
- Copland, 2012, Low-lying placenta: who should be recalled for a follow-up scan J Med Imaging Radiat O, ncol, 56, 158
- Blouin, 2012, Routine third trimester control ultrasound examination for low-lying or marginal placentas diagnosed at mid-pregnancy: is this indicated J Obstet G, ynaecol, 34, 425
- Robinson, 2012, Precise mid-trimester placenta localisation: does it predict adverse outcomes Aust N Z J Obstet G, ynaecol, 52, 156
Cited by
Abnormal Placentation: Placenta Previa, Vasa Previa, and Placenta Accreta
Silver, R. M. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001005 · Cited by 519
Placenta Praevia and Placenta Accreta: Diagnosis and Management: Green‐top Guideline No. 27a
Jauniaux, E., Alfirevic, Z., Bhide, A., Belfort, M., Burton, G., Collins, S., Dornan, S., Jurkovic, D., Kayem, G., Kingdom, J., et al. (2019) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.15306 · Cited by 506
Jauniaux, E., & Bhide, A. (2017) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.02.050 · Cited by 348
Epidemiology of placenta previa accreta: a systematic review and meta-analysis
Jauniaux, E., Grønbeck, L., Bunce, C., Langhoff-Roos, J., & Collins, S. L. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-031193 · Cited by 200
Balayla, J., Desilets, J., & Shrem, G. (2019) · Journal of Perinatal Medicine · doi:10.1515/jpm-2019-0116 · Cited by 52
Metadata
- Authors
- Quant, H. S., Friedman, A. M., Wang, E., Parry, S., & Schwartz, N.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- Venue
- Obstetrics & Gynecology
- Published
- 2014-03
- Volume
- 123
- Issue
- 3
- Pages
- 628-633
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2313990813
- Cited by
- 34
- References
- 18
- Citations by year
- 2026: 2 · 2025: 1 · 2023: 3 · 2022: 6 · 2021: 5 · 2020: 3 · 2019: 5 · 2018: 2 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Obstetrics and Gynecology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and fetal healthcare
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Keywords
- placenta previa, second trimester, transabdominal ultrasound, screening test, transvaginal ultrasound, low-lying placenta, diagnostic thresholds, sensitivity and specificity, pregnancy outcomes
- MeSH terms
- Abdomen, Adolescent, Adult, Child, Female, Follow-Up Studies, Humans, Middle Aged, Placenta Previa, Predictive Value of Tests, Pregnancy, Pregnancy Trimester, Second, Prospective Studies, ROC Curve, Sensitivity and Specificity, Vagina, Multivariate Analysis, Logistic Models, Ultrasonography, Prenatal, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transabdominal Ultrasonography as a Screening Test for Second-Trimester Placenta Previa. https://app.cochat.ai/papers/10.1097/aog.0000000000000129
- The paper
- Quant, H. S., Friedman, A. M., Wang, E., Parry, S., & Schwartz, N. (2014). Transabdominal Ultrasonography as a Screening Test for Second-Trimester Placenta Previa. Obstetrics & Gynecology. https://doi.org/10.1097/aog.0000000000000129
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.