CoChat

Experimental validation of uterine artery volume blood flow measurement by Doppler ultrasonography in pregnant sheep

Open access
Acharya, G., Sitras, V., Erkinaro, T., Mäkikallio, K., Kavasmaa, T., Päkkilä, M., Huhta, J. C., Räsänen, J. · 2007 · Ultrasound in Obstetrics & Gynecology
Cited by 59

The DOI matches its Crossref record.

Abstract

Objective: To test the hypothesis that Doppler‐derived (calculated) uterine artery volume blood flow (cQUtA) reflects accurately volume blood flow measured directly (mQUtA) in an experimental setting. Methods: Five pregnant sheep were instrumented at 122–130 days of gestation under general anesthesia. After a 4‐day recovery period, maternal hemodynamics were varied by administering to the sheep under general anesthesia noradrenaline, beta‐blocker, low oxygen gas mixture, epidural bupivacaine and ephedrine, consecutively. The central venous pressure was obtained with the help of a thermodilution catheter. The mean arterial pressure and acid–base status were monitored using a 16‐gauge polyurethane catheter inserted into the descending aorta via a femoral artery. A 6‐mm transit‐time ultrasonic perivascular flow probe was used to measure the mQUtA. Doppler ultrasonography of the uterine artery was performed and volume blood flow was obtained simultaneously by the transit‐time ultrasonic perivascular flow probe during each phase of the experiment. Results: A total of 31 observations were made. The mQUtA varied between 90 and 800 (mean ± SD, 419 ± 206) mL/min during the experiments. The corresponding values for the cQUtA were 110 and 900 (mean ± SD, 459 ± 211) mL/min. There was a significant correlation (R = 0.76; P < 0.0001) between mQUtA and cQUtA. The mQUtA correlated positively with Doppler‐derived uterine artery absolute velocities, i.e. peak systolic (R = 0.50; P = 0.004), end‐diastolic (R = 0.53; P = 0.002) and time‐averaged maximum (R = 0.69; P < 0.0001) and time‐averaged intensity weighted mean (R = 0.75; P < 0.0001) velocities. Conclusion: cQUtA correlates well with volume blood flow measured directly. Doppler‐derived uterine artery absolute blood flow velocities reflect uteroplacental volume blood flow in pregnant sheep. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.3977

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 59

Metadata

Authors
Acharya, G., Sitras, V., Erkinaro, T., Mäkikallio, K., Kavasmaa, T., Päkkilä, M., Huhta, J. C., & Räsänen, J.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2007-03-27
Volume
29
Issue
4
Pages
401-406
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1987813645
Cited by
59
References
0
FWCI
3.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental validation of uterine artery volume blood flow measurement by Doppler ultrasonography in pregnant sheep. https://app.cochat.ai/papers/10.1002/uog.3977
The paper
Acharya, G., Sitras, V., Erkinaro, T., Mäkikallio, K., Kavasmaa, T., Päkkilä, M., Huhta, J. C., & Räsänen, J. (2007). Experimental validation of uterine artery volume blood flow measurement by Doppler ultrasonography in pregnant sheep. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.3977

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.