CoChat

Evaluation of fetal regional cerebral blood perfusion using power Doppler ultrasound and the estimation of fractional moving blood volume

Open access
Hernandez‐Andrade, E., Jansson, T., Figueroa‐Diesel, H., Rangel‐Nava, H., Acosta‐Rojas, R., Gratacós, E. · 2007 · Ultrasound in Obstetrics & Gynecology
Cited by 47

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objective: To standardize the evaluation of regional fetal brain blood perfusion, using power Doppler ultrasound (PDU) to estimate the fractional moving blood volume (FMBV) and to evaluate the reproducibility of this estimation. Methods: Brain blood perfusion was evaluated in 35 normally grown fetuses at 28–30 weeks of gestation, using PDU. The following cerebral regions were included in the PDU color box: anterior sagittal, complete sagittal, basal ganglia, and cerebellar. Ten consecutive good‐quality images of each anatomical plane were recorded and the delimitation of the region of interest (ROI) was performed off‐line. FMBV was quantified in the ROI of all images and the mean considered as the final value. Differences between regions, variability, reproducibility and agreement between observers were assessed. Results: Power Doppler images of the described anatomical planes were obtained in all cases, regardless of fetal position. The median time for the acquisition of the images was 7 (range 4–12) min. Mean (range) FMBV values were: anterior sagittal, 16.5 (10.7–22.8)%, inter‐patient coefficient of variation (CV) 0.22; complete sagittal, 13.5 (8.8–16.1)%, CV 0.27; basal ganglia, 18.3 (10.7–27.6)%, CV 0.27; and cerebellar, 6.6 (3.0–11.0)%, CV 0.38. There were statistically significant differences in FMBV between cerebellar and complete sagittal ROIs with the frontal and basal ganglia regions. Reproducibility analyses showed an intraclass correlation coefficient of 0.91 (95% CI 0.67–0.97) and an interclass correlation coefficient of 0.87 (95% CI 0.70–0.94). Interobserver agreement showed a mean difference between observers of −0.2 (SD 2.7) with 95% limits of agreement −5.6 to 5.2. Conclusions: When the regions of interest are well defined, the FMBV estimate offers a method to quantify blood flow perfusion in different fetal cerebral areas. There appear to be regional differences in FMBV within the fetal brain. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.4005

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Hernandez‐Andrade, E., Jansson, T., Figueroa‐Diesel, H., Rangel‐Nava, H., Acosta‐Rojas, R., & Gratacós, E.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2007-04-20
Volume
29
Issue
5
Pages
556-561
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2172182940
Cited by
47
References
1
FWCI
5.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.