CoChat

Prediction of ectopic pregnancy in women with a pregnancy of unknown location

Open access
Condous, G., Van Calster, B., Kirk, E., Haider, Z., Timmerman, D., Van Huffel, S., Bourne, T. · 2007 · Ultrasound in Obstetrics & Gynecology
Cited by 103

The DOI matches its Crossref record.

Abstract

Objective: We have previously published on the use of mathematical Model M1 to predict ectopic pregnancy in women with no signs of intra‐ or extrauterine pregnancy. The aim of this study was to improve on the performance of this model for the detection of developing ectopic pregnancies in women with pregnancies of unknown location (PULs). We therefore generated and evaluated a new logistic regression model from simple hormonal data and compared it with Model M1. Methods: Data were collected prospectively from women classified as having a PUL. These women were followed until the diagnosis was established as: a failing PUL, an intrauterine pregnancy (IUP) or an ectopic pregnancy. A multinomial logistic regression model, Model M4, was developed on 201 training cases and it was tested prospectively on another 175 women with a PUL. M4 performance was evaluated using receiver–operating characteristics (ROC) curves and compared with Model M1 based on the human chorionic gonadotropin (hCG) ratio alone. Results: A total of 376 women with a PUL were recruited into this study: 201 in the training set (109 (54.2%) with a failing PUL, 76 (37.8%) with an IUP and 12 (6.0%) with an ectopic pregnancy; four with a persisting PUL were excluded from analysis) and 175 in the test set (94 (53.7%) with a failing PUL, 64 (36.6%) with an IUP and 15 (8.6%) with an ectopic pregnancy; two with a persisting PUL were excluded from analysis). The log serum hCG average ((hCG 0 h + hCG 48 h)/2) and the hCG ratio (hCG 48 h/hCG 0 h) were encoded as variables following multivariate analysis of the basic data. The new Model M4 contained the log of the hCG average, the hCG ratio and its quadratic effect. In the prediction of ectopic pregnancy, M4 gave an area under the ROC curve (AUC) of 0.900 and M1 gave an AUC of 0.842 (P = 0.0303). Conclusions: Although Model M4 is superior to Model M1 when comparing the AUCs for prediction of developing ectopic pregnancies in a PUL population, in real terms this model did not result in substantially more pregnancies being classified correctly as developing ectopic pregnancies. Prospective multicenter studies are needed to assess the diagnostic performance of such models in different populations. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.4015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Condous, G., Van Calster, B., Kirk, E., Haider, Z., Timmerman, D., Van Huffel, S., & Bourne, T.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2007-05-08
Volume
29
Issue
6
Pages
680-687
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2063434807
Cited by
103
References
0
FWCI
6.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.