Routine use of color Doppler during every fetal cardiac examination remains controversial. Many examiners still believe that color should be reserved for cases of suspected congenital heart defect (CHD). In our opinion, color Doppler should be applied in every cardiac scan due to the increase in speed and accuracy that it allows. The purpose of this review is to first explain how color Doppler presets can be optimized and, second, to propose the use of three cross‐sectional planes to simplify color Doppler fetal echocardiography: the four‐chamber (4CV), five‐chamber (5CV) and three‐vessel (3VV) views. A practical approach to the detection of CHD with these planes is presented, with typical findings and possible abnormalities evident during systole and diastole. The diastolic pattern on the 4CV is characterized by two equal color stripes. Connection (‘H’‐sign) or size inequality of the two stripes, or a unilateral color stripe, are important abnormal findings. In systole valve regurgitation should be excluded. In the 5CV, turbulent flow, ventricular septal defect or an overriding aorta (‘Y’‐sign) can be detected. In the 3VV the aorta and pulmonary trunk should be of nearly equal size and demonstrate antegrade flow. Abnormal findings encountered include absence of one vessel, discrepant size of the vessels, retrograde flow in one of the vessels, or the ‘U’‐sign, where the trachea is enclosed between both vessels, suggesting right‐sided aortic arch. In summary, we propose that color Doppler examination utilizing these three planes alone is sufficient to obtain adequate information for the detection of most common CHD. Copyright © 2002 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
“Outcome assessment is reviewed to show the benefit of prenatal diagnosis as it affect outcome for babies with CHD.”
BackgroundInfluentialISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Self-citationTegnander, E., Williams, W., Johansen, O. J., Blaas, H. ‐. K., & Eik‐Nes, S. H. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2710 · Cited by 308
ISUOG Practice Guidelines (updated): fetal cardiac screening
Carvalho, J. S., Axt‐Fliedner, R., Chaoui, R., Copel, J. A., Cuneo, B. F., Goff, D., Gordin Kopylov, L., Hecher, K., Lee, W., Moon‐Grady, A. J., et al. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26224 · Cited by 246
“Although the use of color flow Doppler ultrasonography is not considered mandatory in these Guidelines, becoming familiar with its use and adding it to routine screening is encouraged 103 .”
MethodSelf-citationFanaroff, A. A. (2008) · Yearbook of Neonatal and Perinatal Medicine · doi:10.1016/s8756-5005(08)79214-x · Cited by 207
Metadata
- Authors
- Chaoui, R., & McEwing, R.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2002-12-11
- Volume
- 21
- Issue
- 1
- Pages
- 81-93
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2129260361
- Cited by
- 98
- References
- 0
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three cross‐sectional planes for fetal color Doppler echocardiography. https://app.cochat.ai/papers/10.1002/uog.5
- The paper
- Chaoui, R., & McEwing, R. (2003). Three cross‐sectional planes for fetal color Doppler echocardiography. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.