Prenatal detection of heart defects in a non‐selected population of 30 149 fetuses—detection rates and outcome

Open access
Tegnander, E., Williams, W., Johansen, O. J., Blaas, H.‐G. K., Eik‐Nes, S. H.·2006·Ultrasound in Obstetrics & Gynecology

Abstract

Objectives: To evaluate the detection rate of congenital heart defects (CHD) in a non‐selected population and to follow outcome after diagnosis. Methods: All 30 149 fetuses/newborns that were scheduled to deliver at our hospital between February 1991 and December 2001 were registered prospectively. Of these, 29 460 (98%) fetuses had a prenatal ultrasound scan at our center. The routine fetal examination at approximately 18 weeks' gestation included the four‐chamber view and the great arteries of the fetal heart. The follow‐up period was 2–13 years. Results: Of 97 major CHDs, 55 (57%) were detected prenatally, 16% (9/55) prior to, 66% (36/55) at and 18% (10/55) after the routine scan. Forty‐four percent (19/43) of the isolated CHDs, 67% (36/54) of those with associated malformations and 48% (11/23) of the isolated ductal‐dependent CHDs were detected. Thirty‐eight percent (37/97) had an abnormal karyotype. Of the 55 major CHDs detected, 44% (24) of the pregnancies with lethal/serious fetal malformations were terminated, 15% (8) died in utero, 42% (23) were born alive and 27% (15) were still alive after 2 years. Of the 42 CHDs detected postnatally, 2% (1) were terminated for other reasons, 98% (41) were born alive and 81% (34) were still alive after 2 years. Conclusions: Prenatal detection of CHD is still a challenge, with a 57% detection rate only. Isolated defects are detected less frequently. The overall outcome suggests that the most severe defects are detected with the present screening setting; only 27% of the babies with major CHDs detected were still alive after 2 years. Data from long‐term follow‐up will be of importance for the counseling process. Copyright © 2006 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.2710

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Cited by

See all 308

Metadata

Authors
Tegnander, E., Williams, W., Johansen, O. J., Blaas, H. ‐. K., & Eik‐Nes, S. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2006-02-16
Volume
27
Issue
3
Pages
252-265
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2013742078
Cited by
308
References
50
FWCI
10.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prenatal detection of heart defects in a non‐selected population of 30 149 fetuses—detection rates and outcome. https://app.cochat.ai/papers/10.1002/uog.2710
The paper
Tegnander, E., Williams, W., Johansen, O. J., Blaas, H. ‐. K., & Eik‐Nes, S. H. (2006). Prenatal detection of heart defects in a non‐selected population of 30 149 fetuses—detection rates and outcome. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.2710

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.