Value of prenatal magnetic resonance imaging in the prediction of postnatal outcome in fetuses with diaphragmatic hernia

Jani, J., Cannie, M., Sonigo, P., Robert, Y., Moreno, O., Benachi, A., Vaast, P., Gratacos, E., Nicolaides, K. H., Deprest, J. · 2008 · Ultrasound in Obstetrics & Gynecology
Cited by 202

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Objectives: To investigate the potential value of antenatally determined total fetal lung volume (TFLV) by magnetic resonance imaging (MRI) in the prediction of the postnatal survival in congenital diaphragmatic hernia (CDH). Methods: We examined fetuses with isolated CDH, in which MRI was used at 22–38 weeks of gestation to measure TFLV and assess intrathoracic herniation of abdominal viscera, that were liveborn after 30 weeks of gestation and had postnatal follow‐up until death or discharge from hospital. Regression analysis was used to investigate the effect on survival of gestational age at diagnosis, observed to expected (o/e) TFLV, intrathoracic herniation of the liver, side of CDH, gestational age at MRI, institution, year and gestational age at delivery. In 76 fetuses measurements of o/e TFLV and the lung area to head circumference ratio (LHR) were performed within 2 weeks of each other; in these cases o/e TFLV and o/e LHR were compared for their prediction of postnatal survival. Results: In the 148 cases that fulfilled the entry criteria, multiple regression analysis demonstrated that significant predictors of survival were the presence or absence of intrathoracic herniation of the liver and o/e TFLV. The area under the receiver–operating characteristics curves for prediction of postnatal survival from o/e TFLV was 0.786 (standard error, 0.059; P < 0.001) and that from o/e LHR was 0.743 (standard error, 0.069; P = 0.001). Conclusions: In the assessment of fetuses with CDH, MRI‐based o/e TFLV is useful in the prediction of postnatal survival. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.6234

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Metadata

Authors
Jani, J., Cannie, M., Sonigo, P., Robert, Y., Moreno, O., Benachi, A., Vaast, P., Gratacos, E., Nicolaides, K. H., & Deprest, J.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2008-10-27
Volume
32
Issue
6
Pages
793-799
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2109436680
Cited by
202
References
23
FWCI
13.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Value of prenatal magnetic resonance imaging in the prediction of postnatal outcome in fetuses with diaphragmatic hernia. https://app.cochat.ai/papers/10.1002/uog.6234
The paper
Jani, J., Cannie, M., Sonigo, P., Robert, Y., Moreno, O., Benachi, A., Vaast, P., Gratacos, E., Nicolaides, K. H., & Deprest, J. (2008). Value of prenatal magnetic resonance imaging in the prediction of postnatal outcome in fetuses with diaphragmatic hernia. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.6234

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.