Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 21,856Imbalanced Data Classification TechniquesStatistical Methods in EpidemiologyArtificial Intelligence in Healthcare

The DOI matches its Crossref record; its reference list is not available.

The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Hanley, J A, McNeil, B J·1982·Radiology

Abstract

A representation and interpretation of the area under a receiver operating characteristic (ROC) curve obtained by the "rating" method, or by mathematical predictions based on patient characteristics, is presented. It is shown that in such a setting the area represents the probability that a randomly chosen diseased subject is (correctly) rated or ranked with greater suspicion than a randomly chosen non-diseased subject. Moreover, this probability of a correct ranking is the same quantity that is estimated by the already well-studied nonparametric Wilcoxon statistic. These two relationships are exploited to (a) provide rapid closed-form expressions for the approximate magnitude of the sampling variability, i.e., standard error that one uses to accompany the area under a smoothed ROC curve, (b) guide in determining the size of the sample required to provide a sufficiently reliable estimate of this area, and (c) determine how large sample sizes should be to ensure that one can statistically detect differences in the accuracy of diagnostic techniques.

Overview

Integrity signals

Registry

Crossref · 10.1148/radiology.143.1.7063747

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 10 · Cited by 21,856

Metadata

Authors
Hanley, J. A., & McNeil, B. J.
Venue
Radiology
Published
1982-04
Volume
143
Issue
1
Pages
29-36
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2157825442
Cited by
21,856
References
10
Citations by year
2026: 1106 · 2025: 938 · 2024: 869 · 2023: 882 · 2022: 1002 · 2021: 1101 · 2020: 1061 · 2019: 1015 · 2018: 982 · 2017: 941 · 2016: 866 · 2015: 785 · 2014: 739 · 2013: 747 · 2012: 706
FWCI
16.02
Type
journal article
Language
en
Open access
closed
Locations
  • Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Imbalanced Data Classification Techniques
  • Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
area under the ROC curve, receiver operating characteristic, diagnostic accuracy, Wilcoxon statistic, sampling variability, standard errors, sample size determination, diagnostic test comparison, rating methodology
MeSH terms
Evaluation Studies as Topic, Humans, Mathematics, Models, Theoretical, Statistics as Topic, Technology, Radiologic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The meaning and use of the area under a receiver operating characteristic (ROC) curve. https://app.cochat.ai/papers/10.1148/radiology.143.1.7063747
The paper
Hanley, J. A., & McNeil, B. J. (1982). The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. https://doi.org/10.1148/radiology.143.1.7063747