CoChat

The levator–urethra gap measurement: a more objective means of determining levator avulsion?

Dietz, H. P., Abbu, A., Shek, K. L. · 2008 · Ultrasound in Obstetrics & Gynecology
Cited by 146

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objectives: Levator avulsion, a common childbirth‐related traumatic abnormality of this muscle, is characterized by a widened gap between the muscle insertion and urethra. This study assessed the use of four‐dimensional ultrasound imaging to measure the levator–urethra gap (LUG) in order to identify avulsion. Methods: In a retrospective study, we reviewed the records of 118 women seen for clinical assessment and imaging. Axial plane tomographic ultrasound slices were obtained at intervals of 2.5 mm. The distance between the center of the urethra and the levator insertion was measured, blinded to clinical data, and the results were analyzed with reference to the diagnosis on palpation. An interobserver agreement analysis was conducted on 20 randomly selected patients included in the study. Results: A defect had been palpated in 19/116 women (16%) with complete datasets. LUG measurements were significantly higher in women who had been diagnosed with a levator avulsion on palpation (mean ± SD, 27.6 ± 6.7 mm vs. 19.7 ± 3.4 mm; P < 0.001). The interobserver intraclass correlation coefficient for LUG measurement was good (0.71; 95% CI, 0.61–0.79). Receiver–operating characteristics analysis suggested a cut‐off of 25 mm, with a sensitivity of 63% and a specificity of 94%, for the diagnosis of levator avulsion injury. Conclusions: The measurement of LUG is reproducible and strongly associated with levator avulsion trauma diagnosed on vaginal palpation. A cut‐off of 25 mm may be used for the diagnosis of levator avulsion injury. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.6268

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 146

Metadata

Authors
Dietz, H. P., Abbu, A., & Shek, K. L.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2008-11-26
Volume
32
Issue
7
Pages
941-945
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2114223430
Cited by
146
References
3
FWCI
2.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The levator–urethra gap measurement: a more objective means of determining levator avulsion? https://app.cochat.ai/papers/10.1002/uog.6268
The paper
Dietz, H. P., Abbu, A., & Shek, K. L. (2008). The levator–urethra gap measurement: a more objective means of determining levator avulsion? Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.6268

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.